Literature DB >> 22098941

Dose reduction in digital breast tomosynthesis (DBT) screening using synthetically reconstructed projection images: an observer performance study.

David Gur1, Margarita L Zuley, Maria I Anello, Grace Y Rathfon, Denise M Chough, Marie A Ganott, Christiane M Hakim, Luisa Wallace, Amy Lu, Andriy I Bandos.   

Abstract

RATIONALE AND
OBJECTIVES: The aim of this study was to retrospectively compare the interpretive performance of synthetically reconstructed two-dimensional images in combination with digital breast tomosynthesis (DBT) versus full-field digital mammography (FFDM) plus DBT.
MATERIALS AND METHODS: Ten radiologists trained in reading tomosynthesis examinations interpreted retrospectively, under two modes, 114 mammograms. One mode included the directly acquired full-field digital mammograms combined with DBT, and the other included synthetically reconstructed projection images combined with DBT. The reconstructed images do not require additional radiation exposure. The two modes were compared with respect to sensitivity, namely, recommendation to recall a breast with either a pathology-proven cancer (n = 48) or a high-risk lesion (n = 6), and specificity, namely, no recommendation to recall a breast not depicting an abnormality (n = 144) or depicting only benign abnormalities (n = 30).
RESULTS: The average sensitivity for FFDM with DBT was 0.826, compared to 0.772 for synthetic FFDM with DBT (difference, 0.054; P = .017 and P = .053 for fixed and random reader effects, respectively). The proportions of breasts with no or benign abnormalities recommended to be recalled were virtually the same: 0.298 and 0.297 for the two modalities, respectively (95% confidence intervals for the difference, -0.028 to 0.036 and -0.070 to 0.066 for fixed and random reader effects, respectively). Sixteen additional clusters of microcalcifications ("positive" breasts) were missed by all readers combined when interpreting the mode with synthesized images versus FFDM.
CONCLUSIONS: Lower sensitivity with comparable specificity was observed with the tested version of synthetically generated images compared to FFDM, both combined with DBT. Improved synthesized images with experimentally verified acceptable diagnostic quality will be needed to eliminate double exposure during DBT-based screening.
Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22098941      PMCID: PMC3251730          DOI: 10.1016/j.acra.2011.10.003

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  5 in total

1.  Digital breast tomosynthesis: observer performance study.

Authors:  David Gur; Gordon S Abrams; Denise M Chough; Marie A Ganott; Christiane M Hakim; Ronald L Perrin; Grace Y Rathfon; Jules H Sumkin; Margarita L Zuley; Andriy I Bandos
Journal:  AJR Am J Roentgenol       Date:  2009-08       Impact factor: 3.959

2.  Digital tomosynthesis in breast imaging.

Authors:  L T Niklason; B T Christian; L E Niklason; D B Kopans; D E Castleberry; B H Opsahl-Ong; C E Landberg; P J Slanetz; A A Giardino; R Moore; D Albagli; M C DeJule; P F Fitzgerald; D F Fobare; B W Giambattista; R F Kwasnick; J Liu; S J Lubowski; G E Possin; J F Richotte; C Y Wei; R F Wirth
Journal:  Radiology       Date:  1997-11       Impact factor: 11.105

3.  Localized detection and classification of abnormalities on FFDM and tomosynthesis examinations rated under an FROC paradigm.

Authors:  David Gur; Andriy I Bandos; Howard E Rockette; Margarita L Zuley; Jules H Sumkin; Denise M Chough; Christiane M Hakim
Journal:  AJR Am J Roentgenol       Date:  2011-03       Impact factor: 3.959

4.  Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison.

Authors:  M Lee Spangler; Margarita L Zuley; Jules H Sumkin; Gordan Abrams; Marie A Ganott; Christiane Hakim; Ronald Perrin; Denise M Chough; Ratan Shah; David Gur
Journal:  AJR Am J Roentgenol       Date:  2011-02       Impact factor: 3.959

5.  Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography.

Authors:  Steven P Poplack; Tor D Tosteson; Christine A Kogel; Helene M Nagy
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

  5 in total
  37 in total

1.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

2.  Image toggling saves time in mammography.

Authors:  Trafton Drew; Avi M Aizenman; Matthew B Thompson; Mark D Kovacs; Michael Trambert; Murray A Reicher; Jeremy M Wolfe
Journal:  J Med Imaging (Bellingham)       Date:  2015-10-12

Review 3.  Digital Breast Tomosynthesis: Concepts and Clinical Practice.

Authors:  Alice Chong; Susan P Weinstein; Elizabeth S McDonald; Emily F Conant
Journal:  Radiology       Date:  2019-05-14       Impact factor: 11.105

4.  Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications.

Authors:  Ji Soo Choi; Boo-Kyung Han; Eun Young Ko; Ga Ram Kim; Eun Sook Ko; Ko Woon Park
Journal:  Eur Radiol       Date:  2018-06-21       Impact factor: 5.315

5.  Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions.

Authors:  Margarita L Zuley; Andriy I Bandos; Marie A Ganott; Jules H Sumkin; Amy E Kelly; Victor J Catullo; Grace Y Rathfon; Amy H Lu; David Gur
Journal:  Radiology       Date:  2012-11-09       Impact factor: 11.105

Review 6.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

Review 7.  Supplemental Screening for Breast Cancer in Women With Dense Breasts: A Systematic Review for the U.S. Preventive Services Task Force.

Authors:  Joy Melnikow; Joshua J Fenton; Evelyn P Whitlock; Diana L Miglioretti; Meghan S Weyrich; Jamie H Thompson; Kunal Shah
Journal:  Ann Intern Med       Date:  2016-01-12       Impact factor: 25.391

8.  Digital breast tomosynthesis: observer performance of clustered microcalcification detection on breast phantom images acquired with an experimental system using variable scan angles, angular increments, and number of projection views.

Authors:  Heang-Ping Chan; Mitchell M Goodsitt; Mark A Helvie; Scott Zelakiewicz; Andrea Schmitz; Mitra Noroozian; Chintana Paramagul; Marilyn A Roubidoux; Alexis V Nees; Colleen H Neal; Paul Carson; Yao Lu; Lubomir Hadjiiski; Jun Wei
Journal:  Radiology       Date:  2014-07-07       Impact factor: 11.105

9.  [Future of mammography-based imaging].

Authors:  R Schulz-Wendtland; T Wittenberg; T Michel; A Hartmann; M W Beckmann; C Rauh; S M Jud; B Brehm; M Meier-Meitinger; G Anton; M Uder; P A Fasching
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

10.  Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program.

Authors:  Samantha P Zuckerman; Emily F Conant; Brad M Keller; Andrew D A Maidment; Bruno Barufaldi; Susan P Weinstein; Marie Synnestvedt; Elizabeth S McDonald
Journal:  Radiology       Date:  2016-07-28       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.