Literature DB >> 22086067

Translaminar screws of the axis--an alternative technique for rigid screw fixation in upper cervical spine instability.

D Meyer1, F Meyer, Th Kretschmer, W Börm.   

Abstract

C2 pedicle screws or transarticular atlantoaxial screws are technically demanding and carry an increased risk of vertebral artery injury. In up to 20% of cases, pedicle and transarticular screw placement is not possible due to a high-riding vertebral artery or very small C2 pedicles in addition to other anatomical variations. Translaminar screws have been reported to rigidly capture posterior elements of C2 and therefore appear to be a suitable alternative. We present our first experiences and clinical results with this new method in two neurosurgical spine centers. Twenty-seven adult patients were treated between 2007 and 2010 in two neurosurgical spine departments with C2 translaminar screw fixation for upper cervical spine instability of various origins (e.g., trauma, tumor, dens pseudarthrosis). Eight patients were men and 19 were women. Mean age was 68.9 years. In most cases, translaminar screws were used because of contraindications for pedicle or transarticular screws as a salvage technique. All patients were clinically assessed and had CT scans postoperatively to verify correct screw placement. Follow-up was performed with reexamination on an ambulatory basis. Mean follow-up was 7.6 months for all patients. In 27 patients, 52 translaminar screws were placed. There were no intraoperative complications. Postoperatively, we identified four screw malpositions using a new accuracy grading scale. One screw had to be revised because of violation of the spinal canal >4 mm. None of the patients had additional neurological deficits postoperatively, and all showed stable cervical conditions at follow-up. Two patients died due to causes not associated with the stabilization technique. The fusion rate for patients with C1/C2 fixation is 92.9%. Translaminar screws can be used at least as an additional technique for cases of upper cervical spine instability when pedicle screw placement is contraindicated or not possible. The current data suggest comparable biomechanical stability and fusion rates of translaminar screws to other well-known posterior fixation procedures. In addition, translaminar screw placement is technically less demanding and reduces the risk of vertebral artery injury.

Entities:  

Mesh:

Year:  2011        PMID: 22086067     DOI: 10.1007/s10143-011-0358-x

Source DB:  PubMed          Journal:  Neurosurg Rev        ISSN: 0344-5607            Impact factor:   3.042


  24 in total

1.  Anatomic study of the axis for surgical planning of transarticular screw fixation.

Authors:  Tamaki Igarashi; Shinichi Kikuchi; Katsuhiko Sato; Satoru Kayama; Koji Otani
Journal:  Clin Orthop Relat Res       Date:  2003-03       Impact factor: 4.176

2.  Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw.

Authors:  Makoto Yoshida; Masashi Neo; Shunsuke Fujibayashi; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2006-07-01       Impact factor: 3.468

3.  Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation.

Authors:  Roger Härtl; Robert H Chamberlain; Mary S Fifield; Dean Chou; Volker K H Sonntag; Neil R Crawford
Journal:  J Neurosurg Spine       Date:  2006-10

4.  Anatomic considerations for the placement of C2 laminar screws.

Authors:  Ezequiel H Cassinelli; Michael Lee; Anthony Skalak; Nicholas U Ahn; Neill M Wright
Journal:  Spine (Phila Pa 1976)       Date:  2006-11-15       Impact factor: 3.468

5.  Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques.

Authors:  Roderick Claybrooks; Mark Kayanja; Ryan Milks; Edward Benzel
Journal:  Spine J       Date:  2007-04-16       Impact factor: 4.166

6.  Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation.

Authors:  Joseph Gorek; Emre Acaroglu; Sigurd Berven; Ahad Yousef; Christian M Puttlitz
Journal:  Spine (Phila Pa 1976)       Date:  2005-07-01       Impact factor: 3.468

7.  Study of the anatomical variations of vertebral artery in C2 vertebra with magnetic resonance imaging and its application in the C1-C2 transarticular screw fixation.

Authors:  Sun Wing Lau; Lun Kit Sun; Raymond Lai; Man Sze Karen Luk; Yuet Sun Ng; Nang Man Raymond Wong; Pui Yau Lau
Journal:  Spine (Phila Pa 1976)       Date:  2010-05-15       Impact factor: 3.468

8.  Biomechanical comparison of transpedicular versus intralaminar C2 fixation in C2-C6 subaxial constructs.

Authors:  Michael T Benke; Joseph R O'Brien; Alexander W L Turner; Warren D Yu
Journal:  Spine (Phila Pa 1976)       Date:  2011-01-01       Impact factor: 3.468

Review 9.  Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons.

Authors:  N M Wright; C Lauryssen
Journal:  J Neurosurg       Date:  1998-04       Impact factor: 5.115

10.  Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws.

Authors:  Scott L Parker; Matthew J McGirt; Giannina L Garcés-Ambrossi; Vivek A Mehta; Daniel M Sciubba; Timothy F Witham; Ziya L Gokaslan; Jean-Paul Wolinksy
Journal:  Neurosurgery       Date:  2009-05       Impact factor: 4.654

View more
  8 in total

1.  Surgical treatment of an atlantoaxial fracture after a delayed diagnosis in a comatose patient.

Authors:  Takayuki Imura; Gen Inoue; Toshiyuki Nakazawa; Wataru Saito; Masashi Takaso
Journal:  Eur Spine J       Date:  2015-04-01       Impact factor: 3.134

Review 2.  Pathoanatomy, biomechanics, and treatment of upper cervical ligamentous instability: A literature review.

Authors:  Neeraj Vij; Hannah Tolson; Hayley Kiernan; Veena Agusala; Omar Viswanath; Ivan Urits
Journal:  Orthop Rev (Pavia)       Date:  2022-08-05

3.  Patient-rated outcome after atlantoaxial (C1-C2) fusion: more than a decade of evaluation of 2-year outcomes in 126 patients.

Authors:  F S Kleinstück; T F Fekete; M Loibl; D Jeszenszky; D Haschtmann; F Porchet; A F Mannion
Journal:  Eur Spine J       Date:  2021-09-03       Impact factor: 3.134

Review 4.  Biomechanics and Clinical Application of Translaminar Screws Fixation in Spine: A Review of the Literature.

Authors:  Jimmy J Chan; Nicholas Shepard; Woojin Cho
Journal:  Global Spine J       Date:  2018-04-19

5.  Bicortical Laminar Screws for Posterior Fixation of Subaxial Cervical Spine: A Radiologic Analysis With Computed Tomography Images.

Authors:  Eugene J Park; Woo-Kie Min; Seungbo Sim
Journal:  Global Spine J       Date:  2020-08-26

6.  Management of post-traumatic craniovertebral junction dislocation: A PRISMA-compliant systematic review and meta-analysis of casereports.

Authors:  Tomasz Klepinowski; Bartosz Limanówka; Leszek Sagan
Journal:  Neurosurg Rev       Date:  2020-08-14       Impact factor: 3.042

7.  Feasibility of C2 Vertebra Screws Placement in Patient With Occipitalization of Atlas: A Tomographic Study.

Authors:  Wei Ji; Xiang Liu; Wenhan Huang; Zucheng Huang; Xueshi Li; Jianting Chen; Zenghui Wu; Qingan Zhu
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

Review 8.  Risk of the high-riding variant of vertebral arteries at C2 is increased over twofold in rheumatoid arthritis: a meta-analysis.

Authors:  Tomasz Klepinowski; Jagoda Cembik; Leszek Sagan
Journal:  Neurosurg Rev       Date:  2020-10-26       Impact factor: 3.042

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.