Literature DB >> 20118834

Study of the anatomical variations of vertebral artery in C2 vertebra with magnetic resonance imaging and its application in the C1-C2 transarticular screw fixation.

Sun Wing Lau1, Lun Kit Sun, Raymond Lai, Man Sze Karen Luk, Yuet Sun Ng, Nang Man Raymond Wong, Pui Yau Lau.   

Abstract

STUDY
DESIGN: Use of magnetic resonance imaging (MRI) with Constructive Interference in Steady State (CISS) sequence and isometric voxels to demonstrate the anatomic variations of vertebral artery in C2 vertebra.
OBJECTIVES: To determine the transarticular screw trajectory on CISS MRI and to identify patients with anatomic variations of vertebral artery in C2 vertebra. SUMMARY OF BACKGROUND DATA: Atlantoaxial transarticular screw fixation has been reported to be biomechanically superior to other posterior techniques for atlantoaxial arthrodesis. Vertebral artery injury can be associated with catastrophic sequelae. Anatomic variation of vertebral artery is well recognized and computed tomography scan is the traditional preoperative assessment. However, no report has evaluated the use of MRI in preoperative assessment for the screw trajectories and the anatomic variation of vertebral artery.
METHODS: The 3-dimensional (3D) CISS MRI with isometric voxels was performed in 30 local Chinese patients. The 3D reconstruction images were created to determine the proposed screw trajectories and their relationship with the vertebral arteries.
RESULTS: In 12 patients (40%), the vertebral arteries were lying within the screw trajectories prohibiting transarticular screw fixation on at least one side. Bilateral variations with high risk of vertebral artery injuries were found in 6 patients. The remaining 6 patients had unilateral variations prohibiting the insertion of transarticular screws on one side.
CONCLUSION: The 3D CISS MRI with isometric voxels is a safe and simple imaging technique to outline the vertebral arteries in C2. Reconstruction images are easily created and undistorted. It is one of the useful imaging in preoperative planning of transarticular screw fixation and determination of anatomy of vertebral artery.

Entities:  

Mesh:

Year:  2010        PMID: 20118834     DOI: 10.1097/BRS.0b013e3181bb4f21

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  10 in total

1.  Tomographic analysis of anatomical parameters of the axis in children.

Authors:  Alessandro Gonzalez Torelli; Rafael Bellucci Kohlmann; Olavo Letaif Biraghi; Alexandre Sadao Lutaka; Alexandre Fogaça Cristante; Raphael Martus Marcon
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

2.  Translaminar screws of the axis--an alternative technique for rigid screw fixation in upper cervical spine instability.

Authors:  D Meyer; F Meyer; Th Kretschmer; W Börm
Journal:  Neurosurg Rev       Date:  2011-11-17       Impact factor: 3.042

3.  Percutaneous atlantoaxial anterior transarticular screw fixation combined with mini-open posterior C1/2 wire fusion for patients with a high-riding vertebral artery.

Authors:  Ai-Min Wu; Xiang-Yang Wang; Feng Zhou; Xiao-Lei Zhang; Hua-Zi Xu; Yong-Long Chi
Journal:  J Spinal Cord Med       Date:  2016-02-11       Impact factor: 1.985

4.  [The effect of axis pedicle and intra-axial vertebral artery on C 2 pedicle screw placement].

Authors:  Fan Wu; Hong Li; Shengyu Wan; Tao Gao; Haigang Hu; Xu Lin; Zeli Zhong; Jun Zeng; Chao Wu; Lun Tan
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-07-15

5.  A novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation.

Authors:  Ai-Min Wu; Wenhai Wang; Hui Xu; Zhong-Ke Lin; Xin-Dong Yang; Xiang-Yang Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  PeerJ       Date:  2016-02-23       Impact factor: 2.984

6.  C2 anatomy for translaminar screw placement based on computerized tomographic measurements.

Authors:  Kriangsak Saetia; Anuchit Phankhongsab
Journal:  Asian Spine J       Date:  2015-04-15

7.  Morphometric Analysis and Classification of the Cross-Sectional Shape of the C2 Lamina.

Authors:  Soyeon Kim; Dai-Soon Kwak; In-Beom Kim
Journal:  Biomed Res Int       Date:  2017-09-25       Impact factor: 3.411

Review 8.  Biomechanics and Clinical Application of Translaminar Screws Fixation in Spine: A Review of the Literature.

Authors:  Jimmy J Chan; Nicholas Shepard; Woojin Cho
Journal:  Global Spine J       Date:  2018-04-19

9.  Outcomes of C1-2 joint injections.

Authors:  Christopher M Aiudi; W Michael Hooten; Rebecca A Sanders; James C Watson; Susan M Moeschler; Halena M Gazelka; Bryan C Hoelzer; Jason S Eldrige; Wenchun Qu; Tim J Lamer
Journal:  J Pain Res       Date:  2017-09-18       Impact factor: 3.133

10.  Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture.

Authors:  Ai-Min Wu; Hai-Ming Jin; Zhong-Ke Lin; Yong-Long Chi; Xiang-Yang Wang
Journal:  J Orthop Surg Res       Date:  2017-09-29       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.