Literature DB >> 22082648

Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours.

X J Juan-Senabre1, J López-Tarjuelo, A Conde-Moreno, A Santos-Serra, A L Sánchez-Iglesias, J D Quirós-Higueras, N de Marco Blancas, S Calzada-Feliu, C Ferrer-Albiach.   

Abstract

PURPOSE To evaluate the magnitude of systematic and random errors from a subset of 100 prostate and 26 head and neck (H&N) cancer patients treated with conventional conformal radiotherapy and using image-guided radiotherapy (IGRT). After treatment, the uncertainties involved and the CTV to PTV margin were evaluated. MATERIAL AND METHODS An Elekta Synergy® linear accelerator was used, taking advantage of 3D on-board computed tomography. IGRT with no-action level (NAL) protocol was applied, reporting the 3D translation and rotation corrections. A statistical study was performed to analyse systematic, random and interobserver uncertainties, and, finally, to obtain the CTV to PTV margins. RESULTS The H&N patients' uncertainties found were smaller than those of prostate patients. The CTV to PTV margins assessed, following the guidelines found in the literature, in the three dimensions of space (right-left, superior-inferior, anterior-posterior) were (5.3, 3.5, 3.2) mm for H&N and (7.3, 7.0, 9.0) mm for prostate cancer treatments. CONCLUSIONS It was found that assessing all the involved uncertainties within radiation treatments was very revealing; their quality improves using IGRT techniques and performing extensive data analysis.

Entities:  

Mesh:

Year:  2011        PMID: 22082648     DOI: 10.1007/s12094-011-0740-8

Source DB:  PubMed          Journal:  Clin Transl Oncol        ISSN: 1699-048X            Impact factor:   3.405


  28 in total

1.  Setup error in radiotherapy: on-line correction using electronic kilovoltage and megavoltage radiographs.

Authors:  L Pisani; D Lockman; D Jaffray; D Yan; A Martinez; J Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-06-01       Impact factor: 7.038

2.  Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report.

Authors:  Joep C Stroom; Ben J M Heijmen
Journal:  Radiother Oncol       Date:  2002-07       Impact factor: 6.280

3.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

Authors:  Martin J Murphy; James Balter; Stephen Balter; Jose A BenComo; Indra J Das; Steve B Jiang; C M Ma; Gustavo H Olivera; Raymond F Rodebaugh; Kenneth J Ruchala; Hiroki Shirato; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

4.  A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system.

Authors:  J Gildersleve; D P Dearnaley; P M Evans; M Law; C Rawlings; W Swindell
Journal:  Radiother Oncol       Date:  1994-05       Impact factor: 6.280

5.  Routine clinical on-line portal imaging followed by immediate field adjustment using a tele-controlled patient couch.

Authors:  W De Neve; F Van den Heuvel; M De Beukeleer; M Coghe; L Thon; P De Roover; M Van Lancker; G Storme
Journal:  Radiother Oncol       Date:  1992-05       Impact factor: 6.280

6.  Retroperitoneal tumour radiotherapy: clinical improvements using kilovoltage cone beam computed tomography.

Authors:  Xavier J Juan-Senabre; Carlos Ferrer-Albiach; Marta Rodríguez-Cordón; Agustín Santos-Serra; Juan López-Tarjuelo; Salvador Calzada-Feliu
Journal:  Clin Transl Oncol       Date:  2009-04       Impact factor: 3.405

Review 7.  Set-up verification using portal imaging; review of current clinical practice.

Authors:  C W Hurkmans; P Remeijer; J V Lebesque; B J Mijnheer
Journal:  Radiother Oncol       Date:  2001-02       Impact factor: 6.280

8.  What CTV-to-PTV margins should be applied for prostate irradiation? Four-dimensional quantitative assessment using model-based deformable image registration techniques.

Authors:  Gert J Meijer; Jeroen de Klerk; Karl Bzdusek; Hetty A van den Berg; Rogier Janssen; Michael R Kaus; Patrick Rodrigus; Peter-Paul van der Toorn
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-04-24       Impact factor: 7.038

9.  Effect of the first day correction on systematic setup error reduction.

Authors:  Qiuwen Wu; David Lockman; John Wong; Di Yan
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

10.  Residual set-up errors and margins in on-line image-guided prostate localization in radiotherapy.

Authors:  Per Rugaard Poulsen; Ludvig Paul Muren; Morten Høyer
Journal:  Radiother Oncol       Date:  2007-09-29       Impact factor: 6.280

View more
  4 in total

1.  Assessment and evaluation of MV image guidance system performance in radiotherapy.

Authors:  Nithya Kanakavelu; E James Jebaseelan Samuel
Journal:  Rep Pract Oncol Radiother       Date:  2015-02-07

2.  The contribution of the cone beam Kv CT (CBKvCT) to the reduction in toxicity of prostate cancer treatment with external 3D radiotherapy.

Authors:  Antonio José Conde-Moreno; Carlos Ferrer-Albiach; Mercedes Zabaleta-Meri; Xavi J Juan-Senabre; Agustín Santos-Serra
Journal:  Clin Transl Oncol       Date:  2012-10-02       Impact factor: 3.405

Review 3.  Target margins in radiotherapy of prostate cancer.

Authors:  Slav Yartsev; Glenn Bauman
Journal:  Br J Radiol       Date:  2016-07-20       Impact factor: 3.039

4.  Determination of optimal PTV margin for patients receiving CBCT-guided prostate IMRT: comparative analysis based on CBCT dose calculation with four different margins.

Authors:  Sukhdeep K Gill; Krishna Reddy; Nina Campbell; Changhu Chen; David Pearson
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.