Literature DB >> 11166861

Set-up verification using portal imaging; review of current clinical practice.

C W Hurkmans1, P Remeijer, J V Lebesque, B J Mijnheer.   

Abstract

In this review of current clinical practice of set-up error verification by means of portal imaging, we firstly define the various types of set-up errors using a consistent nomenclature. The different causes of set-up errors are then summarized. Next, the results of a large number of studies regarding patient set-up verification are presented for treatments of patients with head and neck, prostate, pelvis, lung and breast cancer, as well as for mantle field/total body treatments. This review focuses on the more recent studies in order to assess the criteria for good clinical practice in patient positioning. The reported set-up accuracy varies widely, depending on the treatment site, method of immobilization and institution. The standard deviation (1 SD, mm) of the systematic and random errors for currently applied treatment techniques, separately measured along the three principle axes, ranges from 1.6-4.6 and 1.1-2.5 (head and neck), 1.0-3.8 and 1.2-3.5 (prostate), 1.1-4.7 and 1.1-4.9 (pelvis), 1.8-5.1 and 2.2-5.4 (lung), and 1.0-4.7 and 1.7-14.4 (breast), respectively. Recommendations for procedures to quantify, report and reduce patient set-up errors are given based on the studies described in this review. Using these recommendations, the systematic and random set-up errors that can be achieved in routine clinical practice can be less than 2.0 mm (1 SD) for head and neck, 2.5 mm (1 SD) for prostate, 3.0 mm (1 SD) for general pelvic and 3.5 mm (1 SD) for lung cancer treatment techniques.

Entities:  

Mesh:

Year:  2001        PMID: 11166861     DOI: 10.1016/s0167-8140(00)00260-7

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  63 in total

1.  Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours.

Authors:  X J Juan-Senabre; J López-Tarjuelo; A Conde-Moreno; A Santos-Serra; A L Sánchez-Iglesias; J D Quirós-Higueras; N de Marco Blancas; S Calzada-Feliu; C Ferrer-Albiach
Journal:  Clin Transl Oncol       Date:  2011-11       Impact factor: 3.405

2.  Comparisons of the impact of systematic uncertainties in patient setup and prostate motion on doses to the target among different plans for definitive external-beam radiotherapy for prostate cancer.

Authors:  Su Yu Zhu; Takashi Mizowaki; Yoshiki Norihisa; Kenji Takayama; Yasushi Nagata; Masahiro Hiraoka
Journal:  Int J Clin Oncol       Date:  2008-02-29       Impact factor: 3.402

3.  Evaluation of dosimetric margins in prostate IMRT treatment plans.

Authors:  J J Gordon; J V Siebers
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

4.  Influence of interfraction motion on margins for radiotherapy of gastric cancer.

Authors:  A Namysł-Kaletka; J Wydmanski; A Tukiendorf; D Bodusz; W Leszczynski; R Kawczynski; K Grabinska; P Polanowski
Journal:  Br J Radiol       Date:  2015-02-10       Impact factor: 3.039

5.  Comparison between manual and automatic image registration in image-guided radiation therapy using megavoltage cone-beam computed tomography with an imaging beam line for prostate cancer.

Authors:  Takashi Hashido; Shinya Nakasone; Mari Fukao; Seiichi Ota; Shinichi Inoue
Journal:  Radiol Phys Technol       Date:  2018-09-21

6.  Comparison of set-up errors by breast size on wing board by portal imaging.

Authors:  Waseem Raza; Sushma Agarwal; Koilpillai Joseph Maria Das; Sellepolyam Kaliyaperumal Senthil Kumar; Punita Lal
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-06

7.  Correction of systematic set-up error in breast and head and neck irradiation through a no-action level (NAL) protocol.

Authors:  Eva M Lozano; Luis A Pérez; Javier Torres; Carmen Carrascosa; Miguel Sanz; Fermín Mendicote; Antonio Gil
Journal:  Clin Transl Oncol       Date:  2011-01       Impact factor: 3.405

8.  Setup margins and geometric uncertainties in intensity-modulated radiation therapy in treating pituitary adenomas: the experience of Lyon Sud Hospital.

Authors:  B De Bari; I Shakir Shakir; T Chekrine; L Lestrade; V Favrel
Journal:  Radiol Med       Date:  2012-10-22       Impact factor: 3.469

9.  Accurate positioning for head and neck cancer patients using 2D and 3D image guidance.

Authors:  Hyejoo Kang; Dale M Lovelock; Ellen D Yorke; Sergey Kriminski; Nancy Lee; Howard I Amols
Journal:  J Appl Clin Med Phys       Date:  2010-10-27       Impact factor: 2.102

10.  Verification of setup errors in external beam radiation therapy using electronic portal imaging.

Authors:  K Krishna Murthy; Zakiya Al-Rahbi; S S Sivakumar; C A Davis; R Ravichandran; Kamal El Ghamrawy
Journal:  J Med Phys       Date:  2008-04
View more