The clinical impact of the couch top and rails on IMRT and arc therapy.

Kiley B Pulliam1, Rebecca M Howell, David Followill, Dershan Luo, R Allen White, Stephen F Kry.   

Abstract

The clinical impact of the Varian Exact Couch on dose, volume coverage to targets and critical structures, and tumor control probability (TCP) has not been described. Thus, we examined their effects on IMRT and arc therapy. Five clinical prostate patients were planned with both 6 MV eight-field IMRT and 6 MV two-arc RapidArc techniques using the Eclipse treatment planning system. These plans neglected treatment couch attenuation, as is a common clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the dose-volume histograms from each plan iteration. We used a TCP model to calculate losses in tumor control resulting from not accounting for the couch top and rails. We also verified dose measurements in a phantom. Failure to account for the treatment couch and rails resulted in clinically unacceptable dose and volume coverage losses to the targets for both IMRT and RapidArc. The couch caused average prescription dose losses (relative to plans that ignored the couch) to the prostate of 4.2% and 2.0% for IMRT with the rails out and in, respectively, and 3.2% and 2.9% for RapidArc with the rails out and in, respectively. On average, the percentage of the target covered by the prescribed dose dropped to 35% and 84% for IMRT (rails out and in, respectively) and to 18% and 17% for RapidArc (rails out and in, respectively). The TCP was also reduced by as much as 10.5% (6.3% on average). Dose and volume coverage losses for IMRT plans were primarily due to the rails, while the imaging couch top contributed most to losses for RapidArc. Both the couch top and rails contribute to dose and coverage losses that can render plans clinically unacceptable. A follow-up study we performed found that the less attenuating unipanel mesh couch top available with the Varian Exact couch does not cause a clinically impactful loss of dose or coverage for IMRT but still causes an unacceptable loss for RapidArc. Therefore, both the imaging or mesh couch top and the rails should be accounted for in arc therapy. The imaging couch top should be accounted for in IMRT treatment planning or the mesh top can be used, which would not need to be accounted for, and the rails should be moved to avoid the beams during treatment.

Entities:  

Mesh:

Year:  2011        PMID: 22056949      PMCID: PMC4292897          DOI: 10.1088/0031-9155/56/23/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert.

Authors:  Stephen McCormack; Jennifer Diffey; Andrew Morgan
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

2.  A free program for calculating EUD-based NTCP and TCP in external beam radiotherapy.

Authors:  Hiram A Gay; Andrzej Niemierko
Journal:  Phys Med       Date:  2007-09-07       Impact factor: 2.685

3.  Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system.

Authors:  I B Mihaylov; P Corry; Y Yan; V Ratanatharathorn; E G Moros
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

4.  The effect of carbon fibre inserts on the build-up and attenuation of high energy photon beams.

Authors:  B De Ost; J Vanregemorter; B Schaeken; D Van den Weyngaert
Journal:  Radiother Oncol       Date:  1997-12       Impact factor: 6.280

5.  Implementation of a model for estimating tumor control probability for an inhomogeneously irradiated tumor.

Authors:  A Niemierko; M Goitein
Journal:  Radiother Oncol       Date:  1993-11       Impact factor: 6.280

6.  Fitting tumor control probability models to biopsy outcome after three-dimensional conformal radiation therapy of prostate cancer: pitfalls in deducing radiobiologic parameters for tumors from clinical data.

Authors:  S Levegrün; A Jackson; M J Zelefsky; M W Skwarchuk; E S Venkatraman; W Schlegel; Z Fuks; S A Leibel; C C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-11-15       Impact factor: 7.038

7.  An investigation into the use of carbon fibre for megavoltage radiotherapy applications.

Authors:  S J Meara; K A Langmack
Journal:  Phys Med Biol       Date:  1998-05       Impact factor: 3.609

8.  Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device.

Authors:  Sandra C Vieira; Robert S J P Kaatee; Maarten L P Dirkx; Ben J M Heijmen
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

9.  Assessment and management of radiotherapy beam intersections with the treatment couch.

Authors:  Monique Van Prooijen; Thilakshan Kanesalingam; Mohammad K Islam; Robert K Heaton
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

10.  Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop.

Authors:  W Kenji Myint; Malgorzata Niedbala; David Wilkins; Lee H Gerig
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

View more
  17 in total

1.  The role of complexity metrics in a multi-institutional dosimetry audit of VMAT.

Authors:  Conor K McGarry; Christina E Agnew; Mohammad Hussein; Yatman Tsang; Alan McWilliam; Alan R Hounsell; Catharine H Clark
Journal:  Br J Radiol       Date:  2015-10-29       Impact factor: 3.039

2.  Patient-related quality assurance with different combinations of treatment planning systems, techniques, and machines : A multi-institutional survey.

Authors:  Beatrice Steiniger; René Berger; Sabine Eilzer; Christine Kornhuber; Kathleen Lorenz; Torsten Peil; Carsten Reiffenstuhl; Johannes Schilz; Dirk Schröder; Michael Schwedas; Stephanie Pensold; Mathias Walke; Kirsten Weibert; Ulrich Wolf; Tilo Wiezorek
Journal:  Strahlenther Onkol       Date:  2016-11-03       Impact factor: 3.621

3.  Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans.

Authors:  Elizabeth M McKenzie; Peter A Balter; Francesco C Stingo; Jimmy Jones; David S Followill; Stephen F Kry
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

4.  The effect of bladder contrast on dose calculation in volumetric modulated arc therapy planning in patients treated for postoperative prostate cancer.

Authors:  Tülay Ercan; Şefik İğdem; Gül Alço
Journal:  Jpn J Radiol       Date:  2016-02-02       Impact factor: 2.374

5.  A validation of carbon fiber imaging couch top modeling in two radiation therapy treatment planning systems: Philips Pinnacle3 and BrainLAB iPlan RT Dose.

Authors:  Christopher F Njeh; Jason Parker; Joseph Spurgin; Elizabeth Rhoe
Journal:  Radiat Oncol       Date:  2012-11-09       Impact factor: 3.481

6.  Quantification and comparison the dosimetric impact of two treatment couch model in VMAT.

Authors:  Ruohui Zhang; Yulan Gao; Wenwen Bai
Journal:  J Appl Clin Med Phys       Date:  2017-11-02       Impact factor: 2.102

7.  A comprehensive comparison study of three different planar IMRT QA techniques using MapCHECK 2.

Authors:  Vance P Keeling; Salahuddin Ahmad; Hosang Jin
Journal:  J Appl Clin Med Phys       Date:  2013-11-04       Impact factor: 2.102

8.  AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations - Megavoltage Photon and Electron Beams.

Authors:  Jennifer B Smilowitz; Indra J Das; Vladimir Feygelman; Benedick A Fraass; Stephen F Kry; Ingrid R Marshall; Dimitris N Mihailidis; Zoubir Ouhib; Timothy Ritter; Michael G Snyder; Lynne Fairobent
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

9.  Radiation dosimetry effect evaluation of a carbon fiber couch on novel uRT-linac 506c accelerator.

Authors:  Dazhen Jiang; Zhen Cao; Yongchang Wei; Tingting Cao; Jiuling Shen; Conghua Xie; Yunfeng Zhou; Hui Liu; Jun Zhang
Journal:  Sci Rep       Date:  2021-06-29       Impact factor: 4.379

Review 10.  A six-year review of more than 13,000 patient-specific IMRT QA results from 13 different treatment sites.

Authors:  Kiley B Pulliam; David Followill; Laurence Court; Lei Dong; Michael Gillin; Karl Prado; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.