Literature DB >> 9623664

An investigation into the use of carbon fibre for megavoltage radiotherapy applications.

S J Meara1, K A Langmack.   

Abstract

Properties of carbon fibre of relevance to its use for megavoltage radiotherapy applications have been investigated. Measurements have been made of the percentage transmission and percentage build-up of carbon fibre at energies of 5, 6 and 8 MV. The results are presented in comparison with those obtained for other materials commonly used in radiotherapy: polymethylmethacrylate (PMMA), PETG copolyester and expanded polystyrene foam. It was found that carbon fibre has a higher percentage transmission and a lower percentage build-up than either PMMA or PETG copolyester. It was also found that the build-up due to a combination of carbon fibre and 5 cm of polystyrene foam was less than 65% over the energy range for which measurements were made, and much lower than that due to PETG copolyester. It is thus proposed that carbon fibre is a suitable material from which to make devices for use in megavoltage radiotherapy.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9623664     DOI: 10.1088/0031-9155/43/5/025

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Effect of a carbon fiber tabletop on the surface dose and attenuation for high-energy photon beams.

Authors:  Tülay P Meydanci; Gönül Kemikler
Journal:  Radiat Med       Date:  2008-11-22

2.  Effects of Siemens TT-D carbon fiber table top on beam attenuation, and build up region of 6 MV photon beam.

Authors:  Asma Sheykhoo; Sara Abdollahi; Mohammad Hadi Hadizadeh Yazdi; Mahdi Ghorbani; Mohammad Mohammadi
Journal:  Rep Pract Oncol Radiother       Date:  2016-10-17

3.  The clinical impact of the couch top and rails on IMRT and arc therapy.

Authors:  Kiley B Pulliam; Rebecca M Howell; David Followill; Dershan Luo; R Allen White; Stephen F Kry
Journal:  Phys Med Biol       Date:  2011-11-04       Impact factor: 3.609

4.  Absorption ratio of treatment couch and effect on surface and build-up region doses.

Authors:  Taylan Tuğrul
Journal:  Rep Pract Oncol Radiother       Date:  2017-11-20

5.  A validation of carbon fiber imaging couch top modeling in two radiation therapy treatment planning systems: Philips Pinnacle3 and BrainLAB iPlan RT Dose.

Authors:  Christopher F Njeh; Jason Parker; Joseph Spurgin; Elizabeth Rhoe
Journal:  Radiat Oncol       Date:  2012-11-09       Impact factor: 3.481

6.  Impact of 6MV photon beam attenuation by carbon fiber couch and immobilization devices in IMRT planning and dose delivery.

Authors:  R K Munjal; P S Negi; A G Babu; S N Sinha; A K Anand; T Kataria
Journal:  J Med Phys       Date:  2006-04

7.  Increased beam attenuation and surface dose by different couch inserts of treatment tables used in megavoltage radiotherapy.

Authors:  Jan K H Seppälä; Jarmo A J Kulmala
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

8.  Assessment and management of radiotherapy beam intersections with the treatment couch.

Authors:  Monique Van Prooijen; Thilakshan Kanesalingam; Mohammad K Islam; Robert K Heaton
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

9.  Quantification and comparison the dosimetric impact of two treatment couch model in VMAT.

Authors:  Ruohui Zhang; Yulan Gao; Wenwen Bai
Journal:  J Appl Clin Med Phys       Date:  2017-11-02       Impact factor: 2.102

10.  Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop.

Authors:  W Kenji Myint; Malgorzata Niedbala; David Wilkins; Lee H Gerig
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.