UNLABELLED: Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures. INTRODUCTION: Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach. METHODS: We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions. RESULTS: Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]). CONCLUSIONS: This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.
UNLABELLED: Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures. INTRODUCTION: Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach. METHODS: We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions. RESULTS: Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]). CONCLUSIONS: This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.
Authors: Annie W C Kung; Chih-Hsing Wu; Akira Itabashi; Joon Kiong Lee; Hyoung Moo Park; Yanling Zhao; Wing P Chan; David L Kendler; Edward S Leib; E Michael Lewiecki; John P Bilezikian; Sanford Baim Journal: J Clin Densitom Date: 2010-07-21 Impact factor: 2.617
Authors: Marc-Antoine Krieg; Jacques Cornuz; Christiane Ruffieux; Guy Van Melle; Daniel Büche; Maximilian A Dambacher; Didier Hans; Florian Hartl; Hansjorg J Häuselmann; Marius Kraenzlin; Kurt Lippuner; Maurus Neff; Pierro Pancaldi; Rene Rizzoli; Franco Tanzi; Robert Theiler; Alan Tyndall; Claus Wimpfheimer; Peter Burckhardt Journal: J Bone Miner Res Date: 2006-09 Impact factor: 6.741
Authors: Klaus Engelke; Judith E Adams; Gabriele Armbrecht; Peter Augat; Cesar E Bogado; Mary L Bouxsein; Dieter Felsenberg; Masako Ito; Sven Prevrhal; Didier B Hans; E Michael Lewiecki Journal: J Clin Densitom Date: 2008 Jan-Mar Impact factor: 2.617
Authors: Alireza Moayyeri; Stephen Kaptoge; Nichola Dalzell; Robert N Luben; Nicholas J Wareham; Sheila Bingham; Jonathan Reeve; Kay Tee Khaw Journal: Bone Date: 2009-05-07 Impact factor: 4.398
Authors: Claus C Glüer; Richard Eastell; David M Reid; Dieter Felsenberg; Christian Roux; Reinhard Barkmann; Wolfram Timm; Tilo Blenk; Gabi Armbrecht; Alison Stewart; Jackie Clowes; Friederike E Thomasius; Sami Kolta Journal: J Bone Miner Res Date: 2004-03-01 Impact factor: 6.741
Authors: Keith A Wear; Srinidhi Nagaraja; Maureen L Dreher; Saghi Sadoughi; Shan Zhu; Tony M Keaveny Journal: Bone Date: 2017-06-27 Impact factor: 4.398