| Literature DB >> 24605202 |
Wan-Sun Lee1, Woong-Chul Kim2, Hae-Young Kim3, Wook-Tae Kim4, Ji-Hwan Kim2.
Abstract
PURPOSE: This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner.Entities:
Keywords: Dental CAD/CAM system; Digitization of impression bodies; Internal gap; Marginal gap; Zirconia three-unit FPDs
Year: 2014 PMID: 24605202 PMCID: PMC3942523 DOI: 10.4047/jap.2014.6.1.22
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
Fig. 1Image magnified of a quarter silicone replica at the margin area.
Fig. 2Cross-sectional view of locations for gap width measurements on silicone replicas: P1, marginal gap; P2, cervical gap (400 µm above P1); P3, 1/3 of axial from marginal gap; P4, 2/3 of axial from marginal gap; P5, axio-occlusal transition gap; P6, occlusal gap (1/2 of P5and P7); P7, central gap.
Relative mean (SD) of the discrepancies according to the 2 3D virtual model types based on frameworks and 2 teeth types (unit: µm, N=10)
*Model: Framework manufactured using the data which scanned from the model.
*Impression: Framework manufactured using the data which scanned from the impression.
*MG, marginal gap; CG, cervical gap; AWG, axial wall gap; AOTG, axio-occlusal transition gap; OG, occlusal gap; Avg, average.
Estimated mean gaps at 5 different positions (unit: µm, N=10)
*Standard error, Estimated using a repeated measures ANOVA considering 5 different position in a tooth and two model fabrication methods and two teeth types.
#Different alphabets mean significant differences by the post-hoc Bonferroni method (P<.05).
Estimated difference of gaps in two framework fabrication methods and two teeth types (unit: µm, N=10)
*Standard error, Estimated using a repeated measures ANOVA considering 5 different position in a tooth.
Comparative mean marginal gap according to two framework fabrication methods and two teeth types analyzed using the two-way ANOVA (unit: µm, N=10)
*Standard error.
Summary of previous studies on the marginal and internal gap (SD) of the zirconia 3-unit fixed dental prostheses (unit: µm)
*NA, not available.