Literature DB >> 21968546

Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography.

Xiaomei Zhu1, Wenping Chen, Mei Li, Yi Xu, Hai Xu, Yinsu Zhu, Dehang Wang, Lijun Tang.   

Abstract

To investigate the effect on coronary arterial attenuations of contrast material flow rate adjusted to a patient's heart rate during dual source CT coronary angiography (DSCT-CCTA). A total of 296 consecutive patients (mean age: 58.7 years) undergoing DSCT-CCTA without previous coronary stent placement, bypass surgery, congenital or valvular heart disease were included. The image acquisition protocol was standardized (120 kV, 380 mAs) and retrospective electrocardiograph (ECG) gating was used. Patients were randomly assigned to one of three groups [flow rate: G1: dosage/16, G2: dosage/(scan time +8), G3: fixed flow rate]. The groups were compared with respect to the attenuations of the ascending aorta (AA) above coronary ostia, the left main coronary artery (LM), the proximal right coronary artery (RCA), the left anterior descending artery (LAD), the left circumflex artery (LCX), and the contrast to noise ratio of the LM (LM(CNR)) and the proximal RCA (RCA(CNR)). Correlations between heart rate and attenuation of the coronary arteries were evaluated in three groups with linear regression. There was no significant difference in the three groups among the mean attenuations of AA (P = 0.141), LM (P = 0.068), RCA (P = 0.284), LM(CNR) (P = 0.598) and RCA(CNR) (P = 0.546). The attenuations of the LAD and the LCX in group 1 were slightly higher than those in group 2 and 3 (P < 0.05). In group 1, the attenuations of the AA (P < 0.01), LM (P < 0.01), RCA (P < 0.01), LAD (P = 0.02) and LCX (P < 0.01) decreased, respectively, with an increasing heart rate. A similar finding was detected in group 3 (AA: P < 0.01, LM: P < 0.01, RCA: P < 0.01, LAD: P < 0.01 and LCX: P < 0.01). In contrast, the attenuations of the AA (P = 0.55), LM (P = 0.27), RCA (P = 0.77), LAD (P = 0.22) and LCX (P = 0.74) had no significant correlation with heart rate in group 2. In all three groups, LM(CNR) (P = 0.77, 0.69 and 0.73 respectively) and RCA(CNR) (P = 0.75, 0.39 and 0.61 respectively) had no significant correlation with heart rate. Contrast material flow rate adjusted to heart rate can diminish the influence of heart rate on attenuations of the coronary arteries in DSCT-CCTA.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21968546     DOI: 10.1007/s10554-011-9950-y

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  36 in total

1.  Optimal contrast application for cardiac 4-detector-row computed tomography.

Authors:  Christoph R Becker; Cheng Hong; Andreas Knez; Alexander Leber; Roland Bruening; U Joseph Schoepf; Maximilian F Reiser
Journal:  Invest Radiol       Date:  2003-11       Impact factor: 6.016

Review 2.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  Individual modulation of the tube current-seconds to achieve similar levels of image noise in contrast-enhanced abdominal CT.

Authors:  Toshiyuki Irie; Hiroaki Inoue
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

4.  Effect of rate of contrast medium injection on hepatic enhancement at CT.

Authors:  P A Garcia; V M Bonaldi; P M Bret; L Liang; C Reinhold; M Atri
Journal:  Radiology       Date:  1996-04       Impact factor: 11.105

5.  Optimal systolic and diastolic reconstruction windows for coronary CT angiography using 320-detector rows dynamic volume CT.

Authors:  G Sun; M Li; L Li; G-y Li; H Zhang; Z-h Peng
Journal:  Clin Radiol       Date:  2011-04-21       Impact factor: 2.350

6.  Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography.

Authors:  Filippo Cademartiri; Nico R Mollet; Pedro A Lemos; Fransesco Saia; Massimo Midiri; Pim J de Feyter; Gabriel P Krestin
Journal:  AJR Am J Roentgenol       Date:  2006-10       Impact factor: 3.959

7.  Noninvasive coronary angiography with multislice computed tomography.

Authors:  Martin H K Hoffmann; Heshui Shi; Bernd L Schmitz; Florian T Schmid; Michael Lieberknecht; Ralph Schulze; Bernd Ludwig; Ulf Kroschel; Norbert Jahnke; Winfried Haerer; Hans-Juergen Brambs; Andrik J Aschoff
Journal:  JAMA       Date:  2005-05-25       Impact factor: 56.272

8.  Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT.

Authors:  Kazuo Awai; Koichi Takada; Hiromitsu Onishi; Shinichi Hori
Journal:  Radiology       Date:  2002-09       Impact factor: 11.105

9.  Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight.

Authors:  S M Erturk; T Ichikawa; H Sou; T Tsukamoto; U Motosugi; T Araki
Journal:  Clin Radiol       Date:  2007-11-19       Impact factor: 2.350

10.  Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight.

Authors:  Kazuo Awai; Kumiko Hiraishi; Shinichi Hori
Journal:  Radiology       Date:  2004-01       Impact factor: 11.105

View more
  5 in total

1.  Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine.

Authors:  Jean-François Paul; Aude Amato; Adela Rohnean
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-24       Impact factor: 2.357

2.  Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography.

Authors:  Fabian Stenzel; Matthias Rief; Elke Zimmermann; Johannes Greupner; Felicitas Richter; Marc Dewey
Journal:  Eur Radiol       Date:  2014-03-26       Impact factor: 5.315

3.  Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol-A CONSORT compliant article.

Authors:  Xiaomei Zhu; Yusheng Yu; Dinghu Xu; Hong Zhang; Lijun Tang
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

4.  Low dose contrast media in step-and-shoot coronary angiography with third-generation dual-source computed tomography: feasibility of using 30 mL of contrast media in patients with body surface area <1.7 m2.

Authors:  Liang Jin; Bing Jie; Yiyi Gao; An'qi Jiang; Tingwen Weng; Ming Li
Journal:  Quant Imaging Med Surg       Date:  2021-06

5.  Contrast medium administration with a body surface area protocol in step-and-shoot coronary computed tomography angiography with dual-source scanners.

Authors:  Liang Jin; Yiyi Gao; Yingli Sun; Cheng Li; Pan Gao; Wei Zhao; Ming Li
Journal:  Sci Rep       Date:  2020-10-07       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.