Literature DB >> 21962465

Assessment of the applicability of the Hertzian contact theory to edge-loaded prosthetic hip bearings.

Anthony P Sanders1, Rebecca M Brannon.   

Abstract

The components of prosthetic hip bearings may experience in-vivo subluxation and edge loading on the acetabular socket as a result of joint laxity, causing abnormally high, damaging contact stresses. In this research, edge-loaded contact of prosthetic hips is examined analytically and experimentally in the most commonly used categories of material pairs. In edge-loaded ceramic-on-ceramic hips, the Hertzian contact theory yields accurate (conservatively, <10% error) predictions of the contact dimensions. Moreover, the Hertzian theory successfully captures slope and curvature trends in the dependence of contact patch geometry on the applied load. In an edge-loaded ceramic-on-metal pair, a similar degree of accuracy is observed in the contact patch length; however, the contact width is less accurately predicted due to the onset of subsurface plasticity, which is predicted for loads >400N. The Hertzian contact theory is shown to be ill-suited to edge-loaded ceramic-on-polyethylene pairs due to polyethylene's nonlinear material behavior. This work elucidates the methods and the accuracy of applying classical contact theory to edge-loaded hip bearings. The results help to define the applicability of the Hertzian theory to the design of new components and materials to better resist severe edge loading contact stresses. Copyright Â
© 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21962465      PMCID: PMC3208794          DOI: 10.1016/j.jbiomech.2011.08.007

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  22 in total

1.  Experimental and computational simulation of total hip arthroplasty dislocation.

Authors:  C F Scifert; P C Noble; T D Brown; R L Bartz; N Kadakia; N Sugano; R C Johnston; D R Pedersen; J J Callaghan
Journal:  Orthop Clin North Am       Date:  2001-10       Impact factor: 2.472

2.  Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements.

Authors:  M M Mak; A A Besong; Z M Jin; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  2002       Impact factor: 1.617

3.  Hard-on-hard total hip impingement causes extreme contact stress concentrations.

Authors:  Jacob M Elkins; Megan K O'Brien; Nicholas J Stroud; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  Biomechanics of large femoral heads: what they do and don't do.

Authors:  Roy D Crowninshield; William J Maloney; Douglas H Wentz; Steve M Humphrey; Cheryl R Blanchard
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

5.  The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants.

Authors:  D L Bartel; A H Burstein; M D Toda; D L Edwards
Journal:  J Biomech Eng       Date:  1985-08       Impact factor: 2.097

6.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

7.  Effects of acetabular component orientation on dislocation propensity for small-head-size total hip arthroplasty.

Authors:  Mark E Nadzadi; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-01       Impact factor: 2.063

8.  Stripe wear rates in alumina THR--comparison of microseparation simulator study with retrieved implants.

Authors:  Masakazu Manaka; Ian C Clarke; Kengo Yamamoto; Takaaki Shishido; Allen Gustafson; Atsuhiro Imakiire
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-05-15       Impact factor: 3.368

9.  Three-dimensional modeling of in vitro hip kinematics under micro-separation regime for ceramic on ceramic total hip prosthesis: an analysis of vibration and noise.

Authors:  Elhadi Sariali; Todd Stewart; Zongmin Jin; John Fisher
Journal:  J Biomech       Date:  2009-11-04       Impact factor: 2.712

10.  Determining a Surrogate Contact Pair in a Hertzian Contact Problem.

Authors:  Anthony P Sanders; Rebecca M Brannon
Journal:  J Tribol       Date:  2011-04-01       Impact factor: 2.045

View more
  6 in total

1.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

2.  Concomitant evolution of wear and squeaking in dual-severity, lubricated wear testing of ceramic-on-ceramic hip prostheses.

Authors:  Anthony Sanders; Ira Tibbitts; Rebecca Brannon
Journal:  J Orthop Res       Date:  2012-02-21       Impact factor: 3.494

3.  Do obesity and/or stripe wear increase ceramic liner fracture risk? An XFEM analysis.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

4.  Contact-coupled impact of slender rods: analysis and experimental validation.

Authors:  Ira B Tibbitts; Deepika Kakarla; Stephanie Siskey; Jorge A Ochoa; Kevin L Ong; Rebecca M Brannon
Journal:  Exp Mech       Date:  2014-02-01       Impact factor: 2.808

5.  Effect of microseparation on contact mechanics in metal-on-metal hip replacements-A finite element analysis.

Authors:  Feng Liu; Sophie Williams; John Fisher
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-11-05       Impact factor: 3.368

6.  Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints.

Authors:  Feng Liu; John Fisher
Journal:  Tribol Int       Date:  2017-09       Impact factor: 4.872

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.