Fresh blood imaging of the peripheral vasculature: an emerging unenhanced MR technique.

Edward T D Hoey1, Arul Ganeshan, Rakesh Puni, John Henderson, Paul M Crowe.   

Abstract

OBJECTIVE: There is an increasing demand for MR angiography (MRA) techniques that do not require the administration of exogenous contrast material. Fresh blood imaging utilizes an ECG-gated fast spin-echo sequence to acquire images in both the systolic and diastolic phases of the cardiac cycle. Fast systolic arterial flow is differentiated from slower diastolic flow and a subtraction technique is used to produce angiographic images. We describe the technical aspects of performing lower extremity MRA and illustrate some sample cases.
CONCLUSION: Fresh blood imaging is an emerging unenhanced MRA technique that has recently become commercially available. Early clinical trials appear promising and it is anticipated that fresh blood imaging will become invaluable, particularly in patients with impaired renal function. Technical refinements are still required to perfect this novel MR application, particularly for the assessment of distal calf and pedal vessels and for the evaluation of patients with arrhythmias and those with impaired cardiac function.

Entities:  

Mesh:

Year:  2010        PMID: 21098208     DOI: 10.2214/AJR.09.4184

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

Review 1.  Gadolinium and nephrogenic systemic fibrosis: have the alarm bells been silenced?

Authors:  O Tamburrini; A Balducci
Journal:  Radiol Med       Date:  2011-10-21       Impact factor: 3.469

2.  Arterial flow characteristics in the presence of vascular disease and implications for fast spin echo-based noncontrast MR angiography.

Authors:  Pippa Storey; Ruth P Lim; Sooah Kim; David R Stoffel; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2011-09-29       Impact factor: 4.813

3.  Planning deep inferior epigastric perforator flaps for breast reconstruction: a comparison between multidetector computed tomography and magnetic resonance angiography.

Authors:  A Cina; L Barone-Adesi; P Rinaldi; A Cipriani; M Salgarello; R Masetti; L Bonomo
Journal:  Eur Radiol       Date:  2013-04-10       Impact factor: 5.315

4.  High-permittivity thin dielectric padding improves fresh blood imaging of femoral arteries at 3 T.

Authors:  Marc D Lindley; Daniel Kim; Glen Morrell; Marta E Heilbrun; Pippa Storey; Christopher J Hanrahan; Vivian S Lee
Journal:  Invest Radiol       Date:  2015-02       Impact factor: 6.016

Review 5.  Multimodality imaging assessment of bicuspid aortic valve disease, thoracic aortic ectasia, and thoracic aortic aneurysmal disease.

Authors:  Preethi Mani; Reza Reyaldeen; Bo Xu
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

6.  Magnetic resonance angiography using fresh blood imaging in oral and maxillofacial regions.

Authors:  Masafumi Oda; Tatsurou Tanaka; Shinji Kito; Manabu Habu; Masaaki Kodama; Shinya Kokuryo; Ikuya Miyamoto; Daigo Yoshiga; Kensuke Yamauchi; Shinnosuke Nogami; Nao Wakasugi-Sato; Shinobu Matsumoto-Takeda; Ayataka Ishikawa; Ikuko Nishida; Katsura Saeki; Kazumasa Morikawa; Kou Matsuo; Yuji Seta; Yoshihiro Yamashita; Kenshi Maki; Kazuhiro Tominaga; Yasuhiro Morimoto