Abstract

Virtual microscopy has begun to change conventional pathology practice. We tested the reliability of this new technology in transplantation pathology. We studied 40 kidney transplant biopsies for cause and compared reproducibility of Banff scores using virtual slides versus glass slides. Three glass slides per biopsy were scanned as high-resolution digital slides using Aperio ScanScope. Three pathologists independently reviewed the biopsies: twice by glass slides and twice by virtual slides. Eleven histopathological lesions were scored and used to construct diagnosis according to Banff criteria. The intra-observer reproducibility of Banff scores was substantially good using either virtual slides or glass slides (mean κ: 0.69 vs. 0.64, p>0.05). The inter-observer reproducibility of Banff scores was better in virtual slides than in glass slides (mean κ: 0.42 vs. 0.28, p<0.001). Among the lesions, transplant glomerulopathy scoring by virtual slides showed the highest inter-observer reproducibility, with a similar accuracy to glass slides. The agreement for acute rejection between virtual and glass slides was not different from the agreement between two readings of glass slides. Thus, virtual microscopy is a reliable and more reproducible technology and has several advantages over glass slides, e.g., accessibility via internet, no fading. We recommend virtual microscopy for transplant diagnostics, including utilization for clinical trials.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2011        PMID: 21955102     DOI: 10.1111/j.1399-0012.2011.01506.x

Source DB:  PubMed          Journal:  Clin Transplant        ISSN: 0902-0063            Impact factor:   2.863


  24 in total

Review 1.  Morphology in the Digital Age: Integrating High-Resolution Description of Structural Alterations With Phenotypes and Genotypes.

Authors:  Cynthia C Nast; Kevin V Lemley; Jeffrey B Hodgin; Serena Bagnasco; Carmen Avila-Casado; Stephen M Hewitt; Laura Barisoni
Journal:  Semin Nephrol       Date:  2015-05       Impact factor: 5.299

2.  Using computer-assisted morphometrics of 5-year biopsies to identify biomarkers of late renal allograft loss.

Authors:  Aleksandar Denic; Martha C Morales; Walter D Park; Byron H Smith; Walter K Kremers; Mariam P Alexander; Fernando G Cosio; Andrew D Rule; Mark D Stegall
Journal:  Am J Transplant       Date:  2019-05-06       Impact factor: 8.086

Review 3.  Enhancing the Value of Histopathological Assessment of Allograft Biopsy Monitoring.

Authors:  Michelle A Wood-Trageser; Andrew J Lesniak; Anthony J Demetris
Journal:  Transplantation       Date:  2019-07       Impact factor: 4.939

4.  Digital pathology evaluation in the multicenter Nephrotic Syndrome Study Network (NEPTUNE).

Authors:  Laura Barisoni; Cynthia C Nast; J Charles Jennette; Jeffrey B Hodgin; Andrew M Herzenberg; Kevin V Lemley; Catherine M Conway; Jeffrey B Kopp; Matthias Kretzler; Christa Lienczewski; Carmen Avila-Casado; Serena Bagnasco; Sanjeev Sethi; John Tomaszewski; Adil H Gasim; Stephen M Hewitt
Journal:  Clin J Am Soc Nephrol       Date:  2013-02-07       Impact factor: 8.237

5.  Reproducibility of the NEPTUNE descriptor-based scoring system on whole-slide images and histologic and ultrastructural digital images.

Authors:  Laura Barisoni; Jonathan P Troost; Cynthia Nast; Serena Bagnasco; Carmen Avila-Casado; Jeffrey Hodgin; Matthew Palmer; Avi Rosenberg; Adil Gasim; Chrysta Liensziewski; Lino Merlino; Hui-Ping Chien; Anthony Chang; Shane M Meehan; Joseph Gaut; Peter Song; Lawrence Holzman; Debbie Gibson; Matthias Kretzler; Brenda W Gillespie; Stephen M Hewitt
Journal:  Mod Pathol       Date:  2016-04-22       Impact factor: 7.842

6.  A method to reduce variability in scoring antibody-mediated rejection in renal allografts: implications for clinical trials - a retrospective study.

Authors:  Byron Smith; Lynn D Cornell; Maxwell Smith; Cherise Cortese; Xochiquetzal Geiger; Mariam P Alexander; Margaret Ryan; Walter Park; Martha Catalina Morales Alvarez; Carrie Schinstock; Walter Kremers; Mark Stegall
Journal:  Transpl Int       Date:  2018-10-02       Impact factor: 3.782

7.  Quantitative CT analysis of pulmonary ground-glass opacity nodules for distinguishing invasive adenocarcinoma from non-invasive or minimally invasive adenocarcinoma: the added value of using iodine mapping.

Authors:  Ji Ye Son; Ho Yun Lee; Jae-Hun Kim; Joungho Han; Ji Yun Jeong; Kyung Soo Lee; O Jung Kwon; Young Mog Shim
Journal:  Eur Radiol       Date:  2015-05-17       Impact factor: 5.315

Review 8.  Digital pathology in nephrology clinical trials, research, and pathology practice.

Authors:  Laura Barisoni; Jeffrey B Hodgin
Journal:  Curr Opin Nephrol Hypertens       Date:  2017-11       Impact factor: 2.894

9.  Mobile digital fluorescence microscopy for diagnosis of tuberculosis.

Authors:  Asa Tapley; Neil Switz; Clay Reber; J Lucian Davis; Cecily Miller; John Baptist Matovu; William Worodria; Laurence Huang; Daniel A Fletcher; Adithya Cattamanchi
Journal:  J Clin Microbiol       Date:  2013-04-03       Impact factor: 5.948

10.  Reproducibility and Feasibility of Strategies for Morphologic Assessment of Renal Biopsies Using the Nephrotic Syndrome Study Network Digital Pathology Scoring System.

Authors:  Jarcy Zee; Jeffrey B Hodgin; Laura H Mariani; Joseph P Gaut; Matthew B Palmer; Serena M Bagnasco; Avi Z Rosenberg; Stephen M Hewitt; Lawrence B Holzman; Brenda W Gillespie; Laura Barisoni
Journal:  Arch Pathol Lab Med       Date:  2018-02-19       Impact factor: 5.534

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.