OBJECTIVE: We sought to optimize the kilovoltage, tube current, and the radiation dose of computed tomographic arthrography of the hip joint using in vitro methods.
MATERIALS AND METHODS: A phantom was prepared using a left femoral head harvested from a patient undergoing total hip arthroplasty and packed in a condom filled with iodinated contrast. The right hip joint of a cadaver was also injected with iodinated contrast. The phantom and the cadaver were scanned using different values of peak kilovoltage (kVp) and tube current (milliamp seconds, mAs). Three different regions of interest (ROI) were drawn in the cartilage, subchondral bone plate, and intraarticular contrast. The attenuation values, contrast/noise ratio (CNR), and effective dose were calculated. Two independent observers classified the quality of the contrast-cartilage interface and the cartilage-subchondral bone plate interface as (1) diagnostic quality or (2) nondiagnostic quality.
RESULTS: Contrast, cartilage, and subchondral bone plate attenuation values decreased at higher kVp. CNR increased with both kVp and mAs. The qualitative analysis showed that in both phantom and cadaver, at 120 kVp and 50 mAs, the contrast-cartilage and cartilage-subchondral bone plate interfaces were of diagnostic quality, with an effective dose decreased to 0.5 MSv.
CONCLUSIONS: The absolute effective dose is not directly related to the quality of images but to the specific combination of kVp and mAs used for image acquisition. The combination of 120 kVp and 50 mAs can be suggested to decrease the dose without adversely affect the visibility of cartilage and subchondral bone plate.

Entities:  

Mesh:

Year:  2013        PMID: 24281772     DOI: 10.1007/s00256-013-1759-4

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  38 in total

1.  Radiation dose for routine clinical adult brain CT: Variability on different scanners at one institution.

Authors:  Tracy A Jaffe; Jenny K Hoang; Terry T Yoshizumi; Greta Toncheva; Carolyn Lowry; Carl Ravin
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

2.  The effect of angular and longitudinal tube current modulations on the estimation of organ and effective doses in x-ray computed tomography.

Authors:  Marcel van Straten; Paul Deak; Paul C Shrimpton; Willi A Kalender
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

Review 3.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

4.  CT arthrography of the human knee to measure cartilage quality with low radiation dose.

Authors:  J van Tiel; M Siebelt; J H Waarsing; T M Piscaer; M van Straten; R Booij; M L Dijkshoorn; G J Kleinrensink; J A N Verhaar; G P Krestin; H Weinans; E H G Oei
Journal:  Osteoarthritis Cartilage       Date:  2012-03-21       Impact factor: 6.576

5.  Cartilage lesions in the ankle joint: comparison of MR arthrography and CT arthrography.

Authors:  M R Schmid; C W A Pfirrmann; J Hodler; P Vienne; M Zanetti
Journal:  Skeletal Radiol       Date:  2003-04-08       Impact factor: 2.199

Review 6.  CT dose optimisation and reduction in osteoarticular disease.

Authors:  A Gervaise; P Teixeira; N Villani; S Lecocq; M Louis; A Blum
Journal:  Diagn Interv Imaging       Date:  2012-12-28       Impact factor: 4.026

7.  The diagnostic test accuracy of magnetic resonance imaging, magnetic resonance arthrography and computer tomography in the detection of chondral lesions of the hip.

Authors:  Toby O Smith; Michael Simpson; Vivian Ejindu; Caroline B Hing
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-03-30

8.  Comparison of patient doses in 256-slice CT and 16-slice CT scanners.

Authors:  S Mori; M Endo; K Nishizawa; K Murase; H Fujiwara; S Tanada
Journal:  Br J Radiol       Date:  2006-01       Impact factor: 3.039

9.  CT arthrography: in vitro evaluation of single and dual energy for optimization of technique.

Authors:  Naveen Subhas; Maxime Freire; Andrew N Primak; Joshua M Polster; Michael P Recht; William J Davros; Carl S Winalski
Journal:  Skeletal Radiol       Date:  2010-04-25       Impact factor: 2.199

10.  Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians.

Authors:  John D Mathews; Anna V Forsythe; Zoe Brady; Martin W Butler; Stacy K Goergen; Graham B Byrnes; Graham G Giles; Anthony B Wallace; Philip R Anderson; Tenniel A Guiver; Paul McGale; Timothy M Cain; James G Dowty; Adrian C Bickerstaffe; Sarah C Darby
Journal:  BMJ       Date:  2013-05-21
View more
  2 in total

1.  Optimizing radiation dose parameters in MDCT arthrography of the shoulder: illustration of basic concepts in a cadaveric study.

Authors:  Julien Aguet; Fabio Becce; Vincent Dunet; Alain Vlassenbroek; Emmanuel E Coche; Patrick Omoumi
Journal:  Skeletal Radiol       Date:  2019-02-06       Impact factor: 2.199

2.  Optimisation of X-Rays Imaging Techniques for the Assessment of Joint Space.

Authors:  Paolo Simoni
Journal:  J Belg Soc Radiol       Date:  2018-02-07       Impact factor: 1.894

  2 in total