Literature DB >> 28167871

Clinical Results of Oxidized Zirconium Femoral Component in TKA. A Review of Long-Term Survival: Review Article.

Roberto Civinini1, Fabrizio Matassi1, Christian Carulli1, Luigi Sirleo1, Andrea Cozzi Lepri1, Massimo Innocenti1.   

Abstract

BACKGROUND: Oxidized zirconium (OxZr) femoral component for total knee arthroplasty (TKA) have been introduced in an attempt to reduce polyethylene wear and secondary osteolysis and improve longevity of implants. QUESTIONS/PURPOSES: We reviewed clinical studies in literature evaluating OxZr femoral component for TKA. The aim of this review was to evaluate the clinical outcome and survival rate of TKA with an OxZr femoral component.
METHODS: A review of the existing literature was undertaken to collect data on the OxZr femoral component in order to provide a better understanding of its performance. Of 34 studies published in the literature, 8 met the eligibility criteria and were included in the final analysis.
RESULTS: Findings indicated that the mean Knee Society knee score improved in all series from preoperative to postoperative evaluation. The postoperative Knee Society knee score reported range from 84 to 95 and mean postoperative Knee Society functional score range from 74 to 90. The revision rate with this implant is low with up to 12.6 years of follow-up, with three revisions in total. The survival rate ranged from 100-98.7% at 5-7 years to 97.8% at 10 years.
CONCLUSIONS: Excellent clinical outcome and high survival rate has been demonstrated for OxZr femoral component in TKA. No adverse reaction has been described for this new material.

Entities:  

Keywords:  TKA; knee; osteolysis; oxidized zirconium; polyethylene wear; tribology

Year:  2016        PMID: 28167871      PMCID: PMC5264569          DOI: 10.1007/s11420-016-9512-x

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  17 in total

1.  The 5-year results of an oxidized zirconium femoral component for TKA.

Authors:  Massimo Innocenti; Roberto Civinini; Christian Carulli; Fabrizio Matassi; Marco Villano
Journal:  Clin Orthop Relat Res       Date:  2009-10-02       Impact factor: 4.176

2.  Comparison of the Genesis II total knee replacement with oxidised zirconium and cobalt-chromium femoral components in the same patients: a prospective, double-blind, randomised controlled study.

Authors:  Y-H Kim; J-W Park; J-S Kim
Journal:  J Bone Joint Surg Br       Date:  2012-09

3.  Oxidized zirconium femoral component for TKA: a follow-up note of a previous report at a minimum of 10 years.

Authors:  Massimo Innocenti; Fabrizio Matassi; Christian Carulli; Lorenzo Nistri; Roberto Civinini
Journal:  Knee       Date:  2014-04-18       Impact factor: 2.199

4.  Total knee arthroplasty with an oxidised zirconium femoral component: a 5-year follow-up study.

Authors:  Derek H Park; Julian Leong; Stephen J Palmer
Journal:  J Orthop Surg (Hong Kong)       Date:  2014-04       Impact factor: 1.118

5.  Wear of polyethylene against oxidized zirconium femoral components effect of aggressive kinematic conditions and malalignment in total knee arthroplasty.

Authors:  Kace A Ezzet; Juan C Hermida; Nikolai Steklov; Darryl D D'Lima
Journal:  J Arthroplasty       Date:  2011-09-09       Impact factor: 4.757

6.  Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: a randomized controlled trial.

Authors:  Catherine Hui; Lucy Salmon; Shinichi Maeno; Justin Roe; William Walsh; Leo Pinczewski
Journal:  J Bone Joint Surg Am       Date:  2011-04-06       Impact factor: 5.284

Review 7.  Osteolysis after total knee arthroplasty.

Authors:  Sanjay K Gupta; Alice Chu; Amar S Ranawat; John Slamin; Chitranjan S Ranawat
Journal:  J Arthroplasty       Date:  2007-09       Impact factor: 4.757

8.  Five year survival analysis of an oxidised zirconium total knee arthroplasty.

Authors:  Philip Holland; Alasdair J A Santini; John S Davidson; Jill A Pope
Journal:  Knee       Date:  2012-11-16       Impact factor: 2.199

9.  Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components.

Authors:  S E White; L A Whiteside; D S McCarthy; M Anthony; R A Poggie
Journal:  Clin Orthop Relat Res       Date:  1994-12       Impact factor: 4.176

10.  A modular total knee arthroplasty in haemophilic arthropathy.

Authors:  M Innocenti; R Civinini; C Carulli; M Villano; S Linari; M Morfini
Journal:  Knee       Date:  2007-06-29       Impact factor: 2.199