Literature DB >> 21901329

Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin study.

Nobuyasu Komasawa1, Ryusuke Ueki, Hanako Kohama, Shin-ichi Nishi, Yoshiroh Kaminoh.   

Abstract

PURPOSE: The 2010 American Heart Association or European Resuscitation Council guidelines for cardiopulmonary resuscitation emphasize that rescuers should minimize interruption of chest compressions, even for endotracheal intubation. Cervical stabilization should also be maintained during traumatic cardiac arrest. The utility of the Pentax-AWS Airwayscope (AWS) video laryngoscope and Airtraq (ATQ) optic laryngoscope for airway management has been reported under cervical stabilization. We first evaluated ATQ utility during chest compression with or without cervical stabilization and then compared the AWS, ATQ, and Macintosh laryngoscope (McL) during chest compressions under cervical stabilization in a manikin.
METHODS: In the first trial, 19 novice doctors performed tracheal intubation with ATQ during chest compression with or without cervical stabilization. In the second trial, 21 novice doctors performed tracheal intubation on a manikin with cervical stabilization using AWS, ATQ, and McL with or without chest compression in a manikin. The rate of successful intubation, time to intubation, and subjective difficulty of use (visual analog scale) were recorded.
RESULTS: In the first trial, intubation time during chest compression was significantly shortened under cervical stabilization compared to without cervical stabilization (P < 0.05). In the second trial, using McL, 3 participants failed to perform tracheal intubation without chest compression and 11 failed during chest compression (P < 0.05). Using ATQ, all intubations were successful without chest compression, but 5 failed during chest compression (P < 0.05). Intubation time was significantly prolonged by chest compression using McL or ATQ (P < 0.05). All participants successfully secured the airway with AWS regardless of chest compression, and chest compression did not prolong intubation time. Chest compression worsened the score on the visual analog scale of laryngoscopy in the McL trial (P < 0.05), but not in ATQ or AWS trials. Difficulty of tube passage through the glottis increased with chest compression with the McL and ATQ (P < 0.05) but not with AWS.
CONCLUSION: The AWS was superior to McL and ATQ for endotracheal intubation during simulated cervical stabilization and chest compression.

Entities:  

Mesh:

Year:  2011        PMID: 21901329     DOI: 10.1007/s00540-011-1218-0

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  27 in total

1.  Cervical spine motion with direct laryngoscopy and orotracheal intubation. An in vivo cinefluoroscopic study of subjects without cervical abnormality.

Authors:  P D Sawin; M M Todd; V C Traynelis; S B Farrell; A Nader; Y Sato; J D Clausen; V K Goel
Journal:  Anesthesiology       Date:  1996-07       Impact factor: 7.892

Review 2.  Part 8: adult advanced cardiovascular life support: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

Authors:  Robert W Neumar; Charles W Otto; Mark S Link; Steven L Kronick; Michael Shuster; Clifton W Callaway; Peter J Kudenchuk; Joseph P Ornato; Bryan McNally; Scott M Silvers; Rod S Passman; Roger D White; Erik P Hess; Wanchun Tang; Daniel Davis; Elizabeth Sinz; Laurie J Morrison
Journal:  Circulation       Date:  2010-11-02       Impact factor: 29.690

3.  Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy--a manikin study.

Authors:  C H Maharaj; B D Higgins; B H Harte; J G Laffey
Journal:  Anaesthesia       Date:  2006-05       Impact factor: 6.955

4.  Video laryngoscopy for emergency tracheal intubation during chest compression.

Authors:  Takuma Sadamori; Shinji Kusunoki; Makoto Ishida; Tadatsugu Otani; Koichi Tanigawa
Journal:  Resuscitation       Date:  2008-01-18       Impact factor: 5.262

5.  Tracheal intubation using an AirWay Scope in a patient with Halo-Vest Fixation for upper cervical spine injury.

Authors:  K Maruyama; T Yamada; K Hara; H Nakagawa; A Kitamura
Journal:  Br J Anaesth       Date:  2009-04       Impact factor: 9.166

Review 6.  Management of the airway in multitrauma.

Authors:  Mirsad Dupanovic; Heather Fox; Anthony Kovac
Journal:  Curr Opin Anaesthesiol       Date:  2010-04       Impact factor: 2.706

7.  Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Hajime Nomura; Motoi Itani; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-02-03       Impact factor: 2.078

8.  Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study.

Authors:  Y Enomoto; T Asai; T Arai; K Kamishima; Y Okuda
Journal:  Br J Anaesth       Date:  2008-01-31       Impact factor: 9.166

9.  The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases.

Authors:  A Suzuki; Y Toyama; N Katsumi; T Kunisawa; R Sasaki; K Hirota; J J Henderson; H Iwasaki
Journal:  Anaesthesia       Date:  2008-06       Impact factor: 6.955

10.  Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope.

Authors:  Yoshihiro Hirabayashi; Norimasa Seo
Journal:  J Clin Anesth       Date:  2009-06-06       Impact factor: 9.452

View more
  8 in total

1.  Comparison of tube-guided and guideless videolaryngoscope for tracheal intubation during chest compression in a manikin: a randomized crossover trial.

Authors:  Daisuke Okada; Nobuyasu Komasawa; Shunsuke Fujiwara; Toshiaki Minami
Journal:  J Anesth       Date:  2014-10-28       Impact factor: 2.078

2.  Utility of the Pentax-AWS Airwayscope and Macintosh laryngoscope for airway management during chest compressions in 27° left-lateral tilt: a manikin simulation study of maternal cardiopulmonary resuscitation.

Authors:  Hanako Kohama; Nobuyasu Komasawa; Ryusuke Ueki; Noriyasu Yamamoto; Chikara Tashiro; Yoshiroh Kaminoh; Shin-ichi Nishi
Journal:  J Anesth       Date:  2013-04-26       Impact factor: 2.078

3.  Comparison of the conventional Macintosh laryngoscope, the Pentax Airwayscope, and the McGrath MAC video laryngoscope under restricted cervical motion: a manikin study.

Authors:  Atsushi Kotera; Hiroki Irie; Shinsuke Iwashita; Junichi Taniguchi; Shunji Kasaoka; Yoshihiro Kinoshita
Journal:  Acute Med Surg       Date:  2014-10-20

4.  Airtraq, LMA CTrach and Macintosh Laryngoscopes in Tracheal Intubation Training: A Randomized Comparative Manikin Study.

Authors:  Ayten Saraçoğlu; Didem Dal; Ömer Baygın; Fevzi Yılmaz Göğüş
Journal:  Turk J Anaesthesiol Reanim       Date:  2016-04-01

5.  Benefits of using an endotracheal tube introducer as an adjunct to a Macintosh laryngoscope for endotracheal intubation performed by inexperienced doctors during mechanical CPR: A randomized prospective crossover study.

Authors:  Hüseyin Cahit Halhalli; Asım Enes Özbek; Emrah Çelİk; Yavuz Yİğİt; Serkan Yilmaz; Müge Çardak
Journal:  World J Emerg Med       Date:  2019

6.  Cardiac arrest is a predictor of difficult tracheal intubation independent of operator experience in hospitalized patients.

Authors:  Nita Khandelwal; Richard E Galgon; Marwan Ali; Aaron M Joffe
Journal:  BMC Anesthesiol       Date:  2014-05-22       Impact factor: 2.217

7.  Comparison of the utility of the Pentax Airway Scope (AWS) with that of the conventional Macintosh laryngoscope during chest compression: is the AWS an easy-to-use device for a novice?

Authors:  Atsushi Kotera; Hiroki Irie; Shinsuke Iwashita; Junichi Taniguchi; Shunji Kasaoka; Yoshihiro Kinoshita
Journal:  Acute Med Surg       Date:  2014-04-23

8.  Effect of rigid cervical collar on tracheal intubation using Airtraq(®).

Authors:  Padmaja Durga; Chiranjeevi Yendrapati; Geeta Kaniti; Narmada Padhy; Kiran Kumar Anne; Gopinath Ramachandran
Journal:  Indian J Anaesth       Date:  2014-07
  8 in total