Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy--a manikin study.

C H Maharaj1, B D Higgins, B H Harte, J G Laffey.   

Abstract

The Airtraq Laryngoscope is a novel intubation device which allows visualisation of the vocal cords without alignment of the oral, pharyngeal and tracheal axes. We compared the Airtraq with the Macintosh laryngoscope in simulated easy and difficult laryngoscopy. Twenty-five anaesthetists were allowed up to three attempts to intubate the trachea in each of three laryngoscopy scenarios using a Laerdal Intubation Trainer followed by five scenarios using a Laerdal SimMan Manikin. Each anaesthetist then performed tracheal intubation of the normal airway a second time to characterise the learning curve. In the simulated easy laryngoscopy scenarios, there was no difference between the Airtraq and the Macintosh in success of tracheal intubation. The time taken to intubate at the end of the protocol was significantly lower using the Airtraq (9.5 (6.7) vs. 14.2 (7.4) s), demonstrating a rapid acquisition of skills. In the simulated difficult laryngoscopy scenarios, the Airtraq was more successful in achieving tracheal intubation, required less time to intubate successfully, caused less dental trauma, and was considered by the anaesthetists to be easier to use.

Entities:  

Mesh:

Year:  2006        PMID: 16674623     DOI: 10.1111/j.1365-2044.2006.04547.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  40 in total

1.  Efficacy of the Airtraq(®) laryngoscope with a fiberoptic bronchoscope compared with that of Airtraq(®) alone for tracheal intubation: a manikin study.

Authors:  Kohki Nishikawa; Eiko Hukuoka; Toshiya Kawagishi; Yuki Shimodate; Michiaki Yamakage
Journal:  J Anesth       Date:  2010-11-04       Impact factor: 2.078

2.  Emergency use of the Airtraq laryngoscope in traumatic asphyxia: case report.

Authors:  John J M Black
Journal:  Emerg Med J       Date:  2007-07       Impact factor: 2.740

3.  Airway Scope: early clinical experience in 405 patients.

Authors:  Yoshihiro Hirabayashi; Norimasa Seo
Journal:  J Anesth       Date:  2008-02-27       Impact factor: 2.078

Review 4.  Optical and video laryngoscopes for emergency airway management.

Authors:  John C Sakles; Ross Rodgers; Samuel M Keim
Journal:  Intern Emerg Med       Date:  2008-02-15       Impact factor: 3.397

5.  Comparison of intubation performance between the King Vision and Macintosh laryngoscopes in novice personnel: a randomized, crossover manikin study.

Authors:  Yuki Akihisa; Koichi Maruyama; Yukihide Koyama; Rieko Yamada; Akira Ogura; Tomio Andoh
Journal:  J Anesth       Date:  2013-06-30       Impact factor: 2.078

6.  Nasotracheal intubation using the Airtraq versus Macintosh laryngoscope: a manikin study.

Authors:  Yoshihiro Hirabayashi; Norimasa Seo
Journal:  Anesth Prog       Date:  2008

7.  In-line head and neck position is preferable for tracheal intubation with the Airtraq laryngoscope compared to the sniffing position.

Authors:  Yoshihiro Hirabayashi; Norimasa Seo
Journal:  J Anesth       Date:  2008-05-25       Impact factor: 2.078

8.  Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Hanako Kohama; Shin-ichi Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2011-09-07       Impact factor: 2.078

9.  Influence of clinical experience of the Macintosh laryngoscope on performance with the Pentax-AWS Airway Scope(®), a rigid video-laryngoscope, by paramedics in Japan.

Authors:  Kohei Ota; Takuma Sadamori; Shinji Kusunoki; Tadatsugu Otani; Tomoko Tamura; Kazunobu Une; Yoshiko Kida; Junji Itai; Yasumasa Iwasaki; Nobuyuki Hirohashi; Masakazu Nakao; Koichi Tanigawa
Journal:  J Anesth       Date:  2014-12-20       Impact factor: 2.078

10.  Advances in laryngoscopy: rigid indirect laryngoscopy.

Authors:  Deanne R Cheyne; Patrick Doyle
Journal:  F1000 Med Rep       Date:  2010-08-19