Literature DB >> 18477277

The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases.

A Suzuki1, Y Toyama, N Katsumi, T Kunisawa, R Sasaki, K Hirota, J J Henderson, H Iwasaki.   

Abstract

The Pentax-AWS airway scope system is a rigid indirect video laryngoscope with integrated tube guidance. Laryngoscopy and intubation are visualised using a built in LCD monitor which displays the view obtained by a CCD camera mounted in the tip of the laryngoscope. We describe its clinical performance in 320 patients. The Pentax-AWS significantly improved the laryngeal view compared to the Macintosh laryngoscope. Forty-six patients (14%) who were classified as Cormack Lehane glottic view grade 3 or 4 using the Macintosh laryngoscope were classified as grade 1 (45 cases) or 2a (1 case) using the Pentax-AWS airway scope. Laryngeal views measured by percentage of glottic opening score were improved significantly using the Pentax-AWS. Intubation using the Pentax-AWS was successful in all cases, 96% at the first and 4% at the second attempt. The mean (SD) time required to place the tracheal tube was 20 (10) s. The Cormack Lehane grade obtained with the Macintosh blade did not affect the total time to correctly position the tube using the Pentax-AWS. Intubation difficulty scale (score = 0 in 305 patients, score = 1 in 14 and score = 2 in one patient) indicates that tracheal intubation was performed easily in most cases. The Pentax-AWS not only improves the laryngeal view, but its tube guide also facilitates rapid, easy and reliable tracheal intubation under vision. It can be useful in routine anesthesia care and may be advantageous in the situation of unanticipated difficult intubation.

Entities:  

Mesh:

Year:  2008        PMID: 18477277     DOI: 10.1111/j.1365-2044.2008.05452.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  31 in total

1.  Evaluation of tracheal intubation in several positions by the Pentax-AWS Airway Scope: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Motoi Itani; Hajime Nomura; Shin-ich Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-09-14       Impact factor: 2.078

2.  Validation of the Pentax-AWS Airwayscope utility as an intubation device during cardiopulmonary resuscitation on the ground.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Motoi Itani; Shin-ichi Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-05-19       Impact factor: 2.078

3.  Displacement of the epiglottis during intubation with the Pentax-AWS Airway Scope.

Authors:  Akihiro Suzuki; Norifumi Katsumi; Takashi Honda; Tomoki Sasakawa; Takayuki Kunisawa; John J Henderson; Hiroshi Iwasaki
Journal:  J Anesth       Date:  2009-12-29       Impact factor: 2.078

4.  Gastric tube insertion under visual control with the use of the Pentax-AWS®.

Authors:  Shigeo Ikeno; Miwako Nagano; Satoshi Tanaka; Chieko Nishimura; Tomoyuki Kawamata; Mikito Kawamata
Journal:  J Anesth       Date:  2011-04-13       Impact factor: 2.078

5.  Difficult airway management using the Pentax-AWS (Airway Scope) for a patient with bilateral giant thyroid tumors.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Tsuneo Tatara; Yoshiroh Kaminoh; Chikara Tashiro
Journal:  J Anesth       Date:  2010-03-06       Impact factor: 2.078

6.  Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Hajime Nomura; Motoi Itani; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-02-03       Impact factor: 2.078

7.  Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Hanako Kohama; Shin-ichi Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2011-09-07       Impact factor: 2.078

8.  Influence of clinical experience of the Macintosh laryngoscope on performance with the Pentax-AWS Airway Scope(®), a rigid video-laryngoscope, by paramedics in Japan.

Authors:  Kohei Ota; Takuma Sadamori; Shinji Kusunoki; Tadatsugu Otani; Tomoko Tamura; Kazunobu Une; Yoshiko Kida; Junji Itai; Yasumasa Iwasaki; Nobuyuki Hirohashi; Masakazu Nakao; Koichi Tanigawa
Journal:  J Anesth       Date:  2014-12-20       Impact factor: 2.078

9.  Parker Flex-Tip Tube® provides higher intubation success with the Pentax-AWS Airwayscope® despite the AWS tip being inserted into the vallecula.

Authors:  Akihiro Suzuki; Tadahisa Ohmura; Akihito Tampo; Yuya Goto; Ou Oikawa; Takayuki Kunisawa; Hiroshi Iwasaki
Journal:  J Anesth       Date:  2012-03-04       Impact factor: 2.078

10.  Pentax-AWS video laryngoscope for tracheal intubation in a patient with Klippel-Feil syndrome.

Authors:  Young Hyun Jo; Mi Kyeong Kim; Keon-Sik Kim
Journal:  Korean J Anesthesiol       Date:  2013-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.