Literature DB >> 20127370

Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study.

Nobuyasu Komasawa1, Ryusuke Ueki, Hajime Nomura, Motoi Itani, Yoshiroh Kaminoh.   

Abstract

To compare tracheal intubation with the Pentax Airway Scope (AWS) and the Macintosh laryngoscope (McL) during chest compression, 25 anesthesiologists (including 12 specialists having >5 years of experience and 13 trainees having <2 years of experience) performed tracheal intubation using either the McL or the AWS, with or without chest compression, on a manikin. Using the McL, both specialists and trainees took a significantly longer time (P < 0.01) to secure the airway with chest compression (17.3 +/- 3.7 and 22.5 +/- 8.0, respectively) and than without chest compression (11.3 +/- 2.9 and 13.9 +/- 4.4 s, respectively). No significant difference was observed in time needed to secure the airway using the AWS with or without chest compression in both groups. From the standpoint of experience, time to complete intubation for specialists using the McL during chest compression was significantly shorter than that for trainees. In contrast, the difference in time to complete intubation with the AWS during chest compression was not significantly different between the two groups. Based on these results, we conclude that the use of the AWS may reduce the time needed to secure the airway during chest compression.

Entities:  

Mesh:

Year:  2010        PMID: 20127370     DOI: 10.1007/s00540-010-0874-9

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  13 in total

1.  Emergency physician-verified out-of-hospital intubation: miss rates by paramedics.

Authors:  James H Jones; Michael P Murphy; Robert L Dickson; Geoff G Somerville; Edward J Brizendine
Journal:  Acad Emerg Med       Date:  2004-06       Impact factor: 3.451

2.  Major changes in the 2005 AHA Guidelines for CPR and ECC: reaching the tipping point for change.

Authors:  Mary Fran Hazinski; Vinay M Nadkarni; Robert W Hickey; Robert O'Connor; Lance B Becker; Arno Zaritsky
Journal:  Circulation       Date:  2005-11-28       Impact factor: 29.690

3.  Airway Scope for difficult intubation.

Authors:  T Asai; Y Enomoto; Y Okuda
Journal:  Anaesthesia       Date:  2007-02       Impact factor: 6.955

4.  Airway Scope versus Macintosh laryngoscope: a manikin study.

Authors:  Yoshihiro Hirabayashi
Journal:  Emerg Med J       Date:  2007-05       Impact factor: 2.740

5.  Ease of use of the Airway Scope vs the Bullard laryngoscope: a manikin study.

Authors:  Yoshihiro Hirabayashi
Journal:  Can J Anaesth       Date:  2007-05       Impact factor: 5.063

6.  Effect of chest compressions on the time taken to insert airway devices in a manikin.

Authors:  J J Gatward; M J C Thomas; J P Nolan; T M Cook
Journal:  Br J Anaesth       Date:  2007-12-24       Impact factor: 9.166

7.  Misplaced endotracheal tubes by paramedics in an urban emergency medical services system.

Authors:  S H Katz; J L Falk
Journal:  Ann Emerg Med       Date:  2001-01       Impact factor: 5.721

8.  Use of the Pentax-AWS in 293 patients with difficult airways.

Authors:  Takashi Asai; Eugene H Liu; Sanae Matsumoto; Yoshihiro Hirabayashi; Norimasa Seo; Akihiro Suzuki; Takashi Toi; Kazumasa Yasumoto; Yasuhisa Okuda
Journal:  Anesthesiology       Date:  2009-04       Impact factor: 7.892

9.  The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases.

Authors:  A Suzuki; Y Toyama; N Katsumi; T Kunisawa; R Sasaki; K Hirota; J J Henderson; H Iwasaki
Journal:  Anaesthesia       Date:  2008-06       Impact factor: 6.955

10.  Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope.

Authors:  Yoshihiro Hirabayashi; Norimasa Seo
Journal:  J Clin Anesth       Date:  2009-06-06       Impact factor: 9.452

View more
  15 in total

1.  Evaluation of tracheal intubation in several positions by the Pentax-AWS Airway Scope: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Motoi Itani; Hajime Nomura; Shin-ich Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-09-14       Impact factor: 2.078

2.  Validation of the Pentax-AWS Airwayscope utility as an intubation device during cardiopulmonary resuscitation on the ground.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Motoi Itani; Shin-ichi Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-05-19       Impact factor: 2.078

3.  Comparison of Supreme(®) and Soft Seal(®) laryngeal masks for airway management during cardiopulmonary resuscitation in novice doctors: a manikin study.

Authors:  Hanako Kohama; Nobuyasu Komasawa; Ryusuke Ueki; Aoi Samma; Masashi Nakagawa; Shin-ichi Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-12-01       Impact factor: 2.078

4.  Comparison of Laryngeal Mask Supreme® and Soft Seal® for airway management in several positions.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Akari Fujii; Aoi Samma; Masashi Nakagawa; Shin-ich Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2011-04-12       Impact factor: 2.078

5.  Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Hanako Kohama; Shin-ichi Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2011-09-07       Impact factor: 2.078

6.  Comparison of tube-guided and guideless videolaryngoscope for tracheal intubation during chest compression in a manikin: a randomized crossover trial.

Authors:  Daisuke Okada; Nobuyasu Komasawa; Shunsuke Fujiwara; Toshiaki Minami
Journal:  J Anesth       Date:  2014-10-28       Impact factor: 2.078

7.  Evaluation of the efficacy of six supraglottic devices for airway management in dark conditions: a crossover randomized simulation trial.

Authors:  Fumihiro Ohchi; Nobuyasu Komasawa; Kentaro Imagawa; Kaori Okamoto; Toshiaki Minami
Journal:  J Anesth       Date:  2015-07-24       Impact factor: 2.078

8.  Utility of the Pentax-AWS Airwayscope and Macintosh laryngoscope for airway management during chest compressions in 27° left-lateral tilt: a manikin simulation study of maternal cardiopulmonary resuscitation.

Authors:  Hanako Kohama; Nobuyasu Komasawa; Ryusuke Ueki; Noriyasu Yamamoto; Chikara Tashiro; Yoshiroh Kaminoh; Shin-ichi Nishi
Journal:  J Anesth       Date:  2013-04-26       Impact factor: 2.078

9.  Evaluation of chest compression effect on airway management with air-Q, aura-i, i-gel, and Fastrack intubating supraglottic devices by novice physicians: a randomized crossover simulation study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Yoshiroh Kaminoh; Shin-Ichi Nishi
Journal:  J Anesth       Date:  2014-02-22       Impact factor: 2.078

10.  Comparison of positional shift of supraglottic devices resulting from chest compressions: simulation using a manikin and automated chest compression system.

Authors:  Manabu Kitano; Nobuyasu Komasawa; Shunsuke Fujiwara; Toshiaki Minami
Journal:  Acute Med Surg       Date:  2014-10-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.