Literature DB >> 21900621

MR arthrography of the hip: comparison of IDEAL-SPGR volume sequence to standard MR sequences in the detection and grading of cartilage lesions.

Donna G Blankenbaker1, Steven R Ullrick, Richard Kijowski, Kirkland W Davis, Arthur A De Smet, Kazuhiko Shinki, Alejandro Muñoz del Rio, James S Keene.   

Abstract

PURPOSE: To compare the diagnostic performance of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL)-spoiled gradient-recalled echo (SPGR) with that of standard magnetic resonance (MR) arthrography sequences for detecting and grading cartilage lesions within the hip joint during MR arthrography.
MATERIALS AND METHODS: Following institutional review board approval, 67 consecutive hip MR arthrograms were retrospectively reviewed independently by three musculoskeletal radiologists and one musculoskeletal fellow. IDEAL-SPGR images and the two-dimensional images, the latter from the routine MR arthrography protocol, were evaluated at separate sittings to grade each articular surface of the hip joint. By using arthroscopy as the reference standard, the sensitivity and specificity of the two techniques for detecting and grading cartilage lesions were determined. The McNemar test was used to compare diagnostic performance. Interreader agreement was calculated using Fleiss κ values.
RESULTS: For all readers and surfaces combined, the sensitivity and specificity for detecting cartilage lesions was 74% and 77%, respectively, for IDEAL-SPGR and 70% and 84%, respectively, for the routine MR arthrography protocol. IDEAL-SPGR had similar sensitivity (P = .12) to and significantly lower specificity (P < .001) than the routine MR arthrography protocol for depicting cartilage lesions. When analyzing the differences in sensitivity and specificity by reader, the two readers who had experience with IDEAL-SPGR had no significant difference in sensitivity and specificity for detecting cartilage lesions between the two sequences. For all readers and surfaces combined, IDEAL-SPGR had a higher accuracy in correctly grading cartilage lesion (P = .012-.013). Interobserver agreement for detecting cartilage lesions did not differ between the two techniques.
CONCLUSION: IDEAL-SPGR had similar sensitivity and significantly lower specificity for detecting cartilage lesions and higher accuracy for grading cartilage lesions than did a routine MR arthrography protocol; the lower specificity of IDEAL-SPGR for detecting cartilage lesions was not seen in experienced readers. © RSNA, 2011.

Entities:  

Mesh:

Year:  2011        PMID: 21900621     DOI: 10.1148/radiol.11110001

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

Review 1.  MRI of hip cartilage: joint morphology, structure, and composition.

Authors:  Stephanie L Gold; Alissa J Burge; Hollis G Potter
Journal:  Clin Orthop Relat Res       Date:  2012-12       Impact factor: 4.176

2.  Society of Skeletal Radiology 2015 annual meeting summary.

Authors:  Michael G Fox; Laura W Bancroft
Journal:  Skeletal Radiol       Date:  2015-09-04       Impact factor: 2.199

Review 3.  MR Imaging of the Musculoskeletal System Using Ultrahigh Field (7T) MR Imaging.

Authors:  Hamza Alizai; Gregory Chang; Ravinder R Regatte
Journal:  PET Clin       Date:  2018-10

4.  How Does the dGEMRIC Index Change After Surgical Treatment for FAI? A Prospective Controlled Study: Preliminary Results.

Authors:  Florian Schmaranzer; Pascal C Haefeli; Markus S Hanke; Emanuel F Liechti; Stefan F Werlen; Klaus A Siebenrock; Moritz Tannast
Journal:  Clin Orthop Relat Res       Date:  2017-04       Impact factor: 4.176

5.  Diagnostic performance of direct traction MR arthrography of the hip: detection of chondral and labral lesions with arthroscopic comparison.

Authors:  Florian Schmaranzer; Andrea Klauser; Michael Kogler; Benjamin Henninger; Thomas Forstner; Markus Reichkendler; Ehrenfried Schmaranzer
Journal:  Eur Radiol       Date:  2014-12-03       Impact factor: 5.315

6.  3D double-echo steady-state sequence assessment of hip joint cartilage and labrum at 3 Tesla: comparative analysis of magnetic resonance imaging and intraoperative data.

Authors:  Christoph Schleich; Tobias Hesper; Harish S Hosalkar; Fanni Rettegi; Christoph Zilkens; Rüdiger Krauspe; Gerald Antoch; Bernd Bittersohl
Journal:  Eur Radiol       Date:  2017-04-21       Impact factor: 5.315

Review 7.  Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system.

Authors:  Filippo Del Grande; Francesco Santini; Daniel A Herzka; Michael R Aro; Cooper W Dean; Garry E Gold; John A Carrino
Journal:  Radiographics       Date:  2014 Jan-Feb       Impact factor: 5.333

Review 8.  Femoroacetabular impingement.

Authors:  Stephanie Pun; Deepak Kumar; Nancy E Lane
Journal:  Arthritis Rheumatol       Date:  2015-01       Impact factor: 10.995

Review 9.  The role of hip arthroscopy in the management of osteonecrosis.

Authors:  A Papavasiliou; H S Yercan; N Koukoulias
Journal:  J Hip Preserv Surg       Date:  2014-10-08

10.  Best Practices: Hip Femoroacetabular Impingement.

Authors:  Florian Schmaranzer; Arvin B Kheterpal; Miriam A Bredella
Journal:  AJR Am J Roentgenol       Date:  2021-01-21       Impact factor: 3.959

View more