A novel reconstruction algorithm to extend the CT scan field-of-view.

J Hsieh1, E Chao, J Thibault, B Grekowicz, A Horst, S McOlash, T J Myers.   

Abstract

For various reasons, a projection dataset acquired on a computed tomography (CT) scanner can be truncated. That is, a portion of the scanned object is positioned outside the scan field-of-view (SFOV) and the line integrals corresponding to those regions are not measured. A projection truncation problem causes imaging artifacts that lead to suboptimal image quality. In this paper, we propose a reconstruction algorithm that enables an adequate estimation of the projection outside the SFOV. We make use of the fact that the total attenuation of each ideal projection in a parallel sampling geometry remains constant over views. We use the magnitudes and slopes of the projection samples at the location of truncation to estimate water cylinders that can best fit to the projection data outside the SFOV. To improve the robustness of the algorithm, continuity constraints are placed on the fitting parameters. Extensive phantom and patient experiments were conducted to test the robustness and accuracy of the proposed algorithm.

Entities:  

Mesh:

Year:  2004        PMID: 15487717     DOI: 10.1118/1.1776673

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  35 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  Optimization of an on-board imaging system for extremely rapid radiation therapy.

Authors:  Erica M Cherry Kemmerling; Meng Wu; He Yang; Peter G Maxim; Billy W Loo; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

3.  Truncation correction for oblique filtering lines.

Authors:  Stefan Hoppe; Joachim Hornegger; Günter Lauritsch; Frank Dennerlein; Frédéric Noo
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

Review 4.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

5.  Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT--a preliminary study.

Authors:  Lingyun Chen; Chris C Shaw; Mustafa C Altunbas; Chao-Jen Lai; Xinming Liu; Tao Han; Tianpeng Wang; Wei T Yang; Gary J Whitman
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

6.  Dual resolution cone beam breast CT: a feasibility study.

Authors:  Lingyun Chen; Youtao Shen; Chao-Jen Lai; Tao Han; Yuncheng Zhong; Shuaiping Ge; Xinming Liu; Tianpeng Wang; Wei T Yang; Gary J Whitman; Chris C Shaw
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

7.  Artifact reduction in truncated CT using Sinogram completion.

Authors:  R Chityala; K R Hoffmann; S Rudin; D R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005-02

8.  Optimization-based image reconstruction with artifact reduction in C-arm CBCT.

Authors:  Dan Xia; David A Langan; Stephen B Solomon; Zheng Zhang; Buxin Chen; Hao Lai; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

Review 9.  Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging.

Authors:  Tzu C Lee; Adam M Alessio; Robert M Miyaoka; Paul E Kinahan
Journal:  Q J Nucl Med Mol Imaging       Date:  2015-11-17       Impact factor: 2.346

10.  Multimodality rodent imaging chambers for use under barrier conditions with gas anesthesia.

Authors:  Chris Suckow; Claudia Kuntner; Patrick Chow; Robert Silverman; Arion Chatziioannou; David Stout
Journal:  Mol Imaging Biol       Date:  2008-08-05       Impact factor: 3.488

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.