Abstract

In 3-D ultrasound imaging where 2-D transducer arrays with more than hundreds of elements are used, sparse arrays can be used to reduce the number of active ultrasound channels. Under a restriction of desired number of active channels, we can maximize the image quality by optimally choosing the positions of active elements. Here we use the method of simulated annealing to find the optimal configuration of a 2-D sparse array. This algorithm tries to minimize the value of an objective function defined as the energy ratio between the nonfocal and focal regions in the point spread function (PSF). Optimal configurations were found for the cases of choosing 16, 20, 24, 28, and 32 transmit and receive elements from a 16×16-element rectangular transducer array. With only 32 transmit and 32 receive elements, we could achieve an energy ratio of 16%, compared to 6% of the full array, which is the gold standard utilizing all the 256 elements for both transmit and receive. Using Field II, we simulated imaging with the optimal sparse arrays, for off-axis targets as well as on-axis targets, and the resulting images were compared with those from some other configurations, such as full-transmit full-receive, full-transmit x-receive, x-transmit boundary-receive, and so on.

Entities:  

Year:  2010        PMID: 21822365      PMCID: PMC3150118          DOI: 10.1109/ULTSYM.2010.5935854

Source DB:  PubMed          Journal:  Proc IEEE Ultrason Symp        ISSN: 1051-0117


  10 in total

1.  Space-time encoding for high frame rate ultrasound imaging.

Authors:  Thanassis X Misaridis; Jørgen A Jensen
Journal:  Ultrasonics       Date:  2002-05       Impact factor: 2.890

2.  Volumetric ultrasound imaging using 2-D CMUT arrays.

Authors:  Omer Oralkan; A Sanli Ergun; Ching-Hsiang Cheng; Jeremy A Johnson; Mustafa Karaman; Thomas H Lee; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

3.  Sparse 2-D arrays for 3-D phased array imaging--design methods.

Authors:  Andreas Austeng; Sverre Holm
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-08       Impact factor: 2.725

4.  Beam steering with pulsed two-dimensional transducer arrays.

Authors:  D H Turnbull; F S Foster
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

5.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

6.  Thinning and weighting of large planar arrays by simulated annealing.

Authors:  A Trucco
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

7.  Minimally redundant 2-D array designs for 3-D medical ultrasound imaging.

Authors:  Mustafa Karaman; Ira O Wygant; Omer Oralkan; Butrus T Khuri-Yakub
Journal:  IEEE Trans Med Imaging       Date:  2009-01-06       Impact factor: 10.048

8.  Optimization by simulated annealing.

Authors:  S Kirkpatrick; C D Gelatt; M P Vecchi
Journal:  Science       Date:  1983-05-13       Impact factor: 47.728

9.  Simulation of B-scan images from two-dimensional transducer arrays: Part I--Methods and quantitative contrast measurements.

Authors:  D H Turnbull; P K Lum; A T Kerr; F S Foster
Journal:  Ultrason Imaging       Date:  1992-10       Impact factor: 1.578

10.  Two-dimensional random arrays for real time volumetric imaging.

Authors:  R E Davidsen; J A Jensen; S W Smith
Journal:  Ultrason Imaging       Date:  1994-07       Impact factor: 1.578

  10 in total
  3 in total

1.  Design of a Volumetric Imaging Sequence Using a Vantage-256 Ultrasound Research Platform Multiplexed With a 1024-Element Fully Sampled Matrix Array.

Authors:  Jaesok Yu; Heechul Yoon; Yousuf M Khalifa; Stanislav Y Emelianov
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-19       Impact factor: 2.725

2.  Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves.

Authors:  Emmanuel Roux; François Varray; Lorena Petrusca; Christian Cachard; Piero Tortoli; Hervé Liebgott
Journal:  Sci Rep       Date:  2018-06-14       Impact factor: 4.379

3.  Sparse Rectangular and Spiral Array Designs for 3D Medical Ultrasound Imaging.

Authors:  Hansol Yoon; Tai-Kyong Song
Journal:  Sensors (Basel)       Date:  2019-12-27       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.