Literature DB >> 1296337

Simulation of B-scan images from two-dimensional transducer arrays: Part I--Methods and quantitative contrast measurements.

D H Turnbull1, P K Lum, A T Kerr, F S Foster.   

Abstract

Recently, theoretical investigations of the beamforming capability of two-dimensional (2-D) transducer arrays have characterized the array parameters required to steer a symmetrically focused ultrasound beam up to 45 degrees off-axis. These investigations have also shown that the number of elements in a steered 2-D array can be dramatically reduced by using a sparse set of elements, randomly distributed throughout the aperture of the transducer. The penalty paid for the use of a sparse array is the development of a "pedestal" sidelobe in the beam profile, the amplitude of which increases as the number of elements in the array decreases. In this paper the potential of 2-D arrays for medical imaging is assessed by simulating B-scan images of spherical lesions, both cystic and scattering, embedded in a large random scattering volume. Similar contrast characteristics over a range of cyst sizes are demonstrated for a dense 2-D array and a sparse array with 1/8th the number of elements, both operating at 5 MHz. A 32nd order sparse array is shown to perform at a reduced level, producing unacceptable artifactual echoes within images of cysts. The 8th order sparse array pattern has been fabricated on a fixed-focus poly(vinylidene difluoride) transducer using photolithographic techniques. Experimental images from this transducer are used to verify some of the theoretical predictions made in this paper. Comparisons between simulated B-scan images from linear and 2-D phased arrays are presented in a companion paper.

Entities:  

Mesh:

Year:  1992        PMID: 1296337     DOI: 10.1177/016173469201400401

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  3 in total

1.  Fabrication and evaluation of fully-sampled, two-dimensional transducer array for "Sonic Window" imaging system.

Authors:  Matthew D C Eames; John A Hossack
Journal:  Ultrasonics       Date:  2008-03-05       Impact factor: 2.890

2.  Design Optimization for a 2-D Sparse Transducer Array for 3-D Ultrasound Imaging.

Authors:  Jung Woo Choe; Omer Oralkan; Pierre T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10-11

3.  Intravascular Ultrasound Imaging With Virtual Source Synthetic Aperture Focusing and Coherence Factor Weighting.

Authors:  Mingyue Yu; Yang Li; Teng Ma; K Kirk Shung; Qifa Zhou
Journal:  IEEE Trans Med Imaging       Date:  2017-07-04       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.