Literature DB >> 21820094

Deriving tissue density and elastic modulus from microCT bone scans.

David W Wagner1, Derek P Lindsey, Gary S Beaupre.   

Abstract

Tissue level density and elastic modulus are intrinsic properties that can be used to quantify bone material and analyses incorporating those quantities have been used to evaluate bone on a macroscopic scale. Micro-computed tomography (microCT) technology has been used to construct tissue level finite element models to simulate macroscopic fracture strength, however, a single method for assigning voxel-specific tissue density and elastic modulus based on those data has not been universally accepted. One method prevalent in the literature utilizes an empirical relationship that derives tissue stiffness as a function of bone calcium content weight fraction. To derive calcium content weight fraction from microCT scans, a measure of tissue density is required and a constant value is traditionally used. However, experimental data suggest a non-trivial amount of tissue heterogeneity suggesting a constant tissue density may not be appropriate. A theoretical derivation for determining the relationship between voxel-specific tissue density and microCT scan data (i.e., microCT derived tissue mineral density (TMD), mgHA/cm(3)) and bone constituent properties is proposed. Constant model parameters used in the derivation include the density of water, ash, and organics (i.e., bone constituents) and the volume fraction of the organics constituent. The effect of incorporating the theoretically derived tissue density (instead of a constant value) in determining voxel-specific elastic modulus resulted in a maximum observed increase of 12GPa (5.9GPa versus 17.9GPa, for the constant value and derived tissue density formulations, respectively) for a measured TMD of 1.02gHA/cm(3). Average and bounding quantities for the four constant model parameters were defined from the literature and the influence of those values on the derived tissue density and elastic modulus relationships were also evaluated. The theoretical relationships of tissue density and elastic modulus, with the average constant model parameters applied, were consistent with previously published empirical relationships derived from experimental data. Tissue density as a function of microCT TMD was formulated as a linear relationship and the density of water and ash was shown to solely influence the proportionality (i.e., slope) between those values. The density of water and organics (i.e., collagen) and the volume fraction of the organics constituent were shown to influence the constant offset (intercept) between tissue density and TMD with no influence from ash density. Incorporating tissue density heterogeneity into the derivation of elastic modulus resulted in a significant increase in predicted modulus (for microCT TMD ranges observed for healthy tissue) as compared to when a constant tissue density was used. The presented approach provides a novel method for deriving tissue-level bone material properties and quantifies the effect of assuming tissue homogeneity when calculating elastic modulus (when using a prevalent method in the literature) from microCT scan data. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21820094     DOI: 10.1016/j.bone.2011.07.021

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  14 in total

1.  Predicting mouse vertebra strength with micro-computed tomography-derived finite element analysis.

Authors:  Jeffry S Nyman; Sasidhar Uppuganti; Alexander J Makowski; Barbara J Rowland; Alyssa R Merkel; Julie A Sterling; Todd L Bredbenner; Daniel S Perrien
Journal:  Bonekey Rep       Date:  2015-04-22

2.  A novel technique with reduced computed tomography exposure to predict vertebral compression fracture: a finite element study based on rat vertebrae.

Authors:  Giovanni F Solitro; Florian Mainnemare; Farid Amirouche; Ankit Mehta
Journal:  Med Biol Eng Comput       Date:  2018-11-07       Impact factor: 2.602

Review 3.  Polymerization shrinkage assessment of dental resin composites: a literature review.

Authors:  Dalia Kaisarly; Moataz El Gezawi
Journal:  Odontology       Date:  2016-08-19       Impact factor: 2.634

4.  Dietary Advanced Glycation End Products Have Sex- and Age-Dependent Effects on Vertebral Bone Microstructure and Mechanical Function in Mice.

Authors:  Svenja Illien-Jünger; Paolo Palacio-Mancheno; William F Kindschuh; Xue Chen; Grazyna E Sroga; Deepak Vashishth; James C Iatridis
Journal:  J Bone Miner Res       Date:  2017-11-27       Impact factor: 6.741

Review 5.  On challenges in clinical assessment of hip fracture risk using image-based biomechanical modelling: a critical review.

Authors:  Yunhua Luo
Journal:  J Bone Miner Metab       Date:  2021-01-09       Impact factor: 2.626

6.  Biological evaluation and finite-element modeling of porous poly(para-phenylene) for orthopaedic implants.

Authors:  Hyunhee Ahn; Ravi R Patel; Anthony J Hoyt; Angela S P Lin; F Brennan Torstrick; Robert E Guldberg; Carl P Frick; R Dana Carpenter; Christopher M Yakacki; Nick J Willett
Journal:  Acta Biomater       Date:  2018-03-18       Impact factor: 8.947

7.  Microstructural changes associated with osteoporosis negatively affect loading-induced fluid flow around osteocytes in cortical bone.

Authors:  Vittorio Gatti; Evan M Azoulay; Susannah P Fritton
Journal:  J Biomech       Date:  2017-11-16       Impact factor: 2.712

Review 8.  Establishing biomechanical mechanisms in mouse models: practical guidelines for systematically evaluating phenotypic changes in the diaphyses of long bones.

Authors:  Karl J Jepsen; Matthew J Silva; Deepak Vashishth; X Edward Guo; Marjolein C H van der Meulen
Journal:  J Bone Miner Res       Date:  2015-06       Impact factor: 6.741

9.  Dynamic permeability of the lacunar-canalicular system in human cortical bone.

Authors:  M Benalla; P E Palacio-Mancheno; S P Fritton; L Cardoso; S C Cowin
Journal:  Biomech Model Mechanobiol       Date:  2013-10-22

10.  Monetite and brushite coated magnesium: in vivo and in vitro models for degradation analysis.

Authors:  Shaylin Shadanbaz; Jemimah Walker; Tim B F Woodfield; Mark P Staiger; George J Dias
Journal:  J Mater Sci Mater Med       Date:  2013-10-01       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.