Development and evaluation of a model-based downscatter compensation method for quantitative I-131 SPECT.

Na Song1, Yong Du, Bin He, Eric C Frey.   

Abstract

PURPOSE: The radionuclide 131I has found widespread use in targeted radionuclide therapy (TRT), partly due to the fact that it emits photons that can be imaged to perform treatment planning or posttherapy dose verification as well as beta rays that are suitable for therapy. In both the treatment planning and dose verification applications, it is necessary to estimate the activity distribution in organs or tumors at several time points. In vivo estimates of the 131I activity distribution at each time point can be obtained from quantitative single-photon emission computed tomography (QSPECT) images and organ activity estimates can be obtained either from QSPECT images or quantification of planar projection data. However, in addition to the photon used for imaging, 131I decay results in emission of a number of other higher-energy photons with significant abundances. These higher-energy photons can scatter in the body, collimator, or detector and be counted in the 364 keV photopeak energy window, resulting in reduced image contrast and degraded quantitative accuracy; these photons are referred to as downscatter. The goal of this study was to develop and evaluate a model-based downscatter compensation method specifically designed for the compensation of high-energy photons emitted by 131I and detected in the imaging energy window.
METHODS: In the evaluation study, we used a Monte Carlo simulation (MCS) code that had previously been validated for other radionuclides. Thus, in preparation for the evaluation study, we first validated the code for 131I imaging simulation by comparison with experimental data. Next, we assessed the accuracy of the downscatter model by comparing downscatter estimates with MCS results. Finally, we combined the downscatter model with iterative reconstruction-based compensation for attenuation (A) and scatter (S) and the full (D) collimator-detector response of the 364 keV photons to form a comprehensive compensation method. We evaluated this combined method in terms of quantitative accuracy using the realistic 3D NCAT phantom and an activity distribution obtained from patient studies. We compared the accuracy of organ activity estimates in images reconstructed with and without addition of downscatter compensation from projections with and without downscatter contamination.
RESULTS: We observed that the proposed method provided substantial improvements in accuracy compared to no downscatter compensation and had accuracies comparable to reconstructions from projections without downscatter contamination.
CONCLUSIONS: The results demonstrate that the proposed model-based downscatter compensation method is effective and may have a role in quantitative 131I imaging.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21815394      PMCID: PMC3125085          DOI: 10.1118/1.3590382

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  27 in total

1.  Procedure guideline for therapy of thyroid disease with (131)iodine.

Authors:  Donald A Meier; David R Brill; David V Becker; Susan E M Clarke; Edward B Silberstein; Henry D Royal; Helena R Balon
Journal:  J Nucl Med       Date:  2002-06       Impact factor: 10.057

Review 2.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

3.  Effects of shortened acquisition time on accuracy and precision of quantitative estimates of organ activity.

Authors:  Bin He; Eric C Frey
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

4.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

5.  Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents.

Authors:  Bin He; Eric C Frey
Journal:  Phys Med Biol       Date:  2006-08-02       Impact factor: 3.609

6.  3-D Monte Carlo-Based Scatter Compensation in Quantitative I-131 SPECT Reconstruction.

Authors:  Yuni K Dewaraja; Michael Ljungberg; Jeffrey A Fessler
Journal:  IEEE Trans Nucl Sci       Date:  2006       Impact factor: 1.679

7.  In vivo quantitation of lesion radioactivity using external counting methods.

Authors:  S R Thomas; H R Maxon; J G Kereiakes
Journal:  Med Phys       Date:  1976 Jul-Aug       Impact factor: 4.071

8.  Correction of nonuniform attenuation in cardiac SPECT imaging.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; J G Ballard; J R Perry; W H McCartney; J Berg
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

Review 9.  Quantitative SPECT imaging: a review and recommendations by the Focus Committee of the Society of Nuclear Medicine Computer and Instrumentation Council.

Authors:  M S Rosenthal; J Cullom; W Hawkins; S C Moore; B M Tsui; M Yester
Journal:  J Nucl Med       Date:  1995-08       Impact factor: 10.057

10.  Phase II trial of 131I-B1 (anti-CD20) antibody therapy with autologous stem cell transplantation for relapsed B cell lymphomas.

Authors:  O W Press; J F Eary; F R Appelbaum; P J Martin; W B Nelp; S Glenn; D R Fisher; B Porter; D C Matthews; T Gooley
Journal:  Lancet       Date:  1995-08-05       Impact factor: 79.321

View more
  15 in total

1.  Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.

Authors:  Xing Rong; Yong Du; Michael Ljungberg; Erwann Rault; Stefaan Vandenberghe; Eric C Frey
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

2.  No-gold-standard evaluation of image-acquisition methods using patient data.

Authors:  Abhinav K Jha; Eric Frey
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-10

Review 3.  Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.

Authors:  W Paul Segars; B M W Tsui; George S K Fung; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2017-08-10       Impact factor: 10.048

4.  Design of a digital phantom population for myocardial perfusion SPECT imaging research.

Authors:  Michael Ghaly; Yong Du; George S K Fung; Benjamin M W Tsui; Jonathan M Links; Eric Frey
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

5.  Current pediatric administered activity guidelines for 99m Tc-DMSA SPECT based on patient weight do not provide the same task-based image quality.

Authors:  Ye Li; Shannon O'Reilly; Donika Plyku; S Ted Treves; Frederic Fahey; Yong Du; Xinhua Cao; Briana Sexton-Stallone; Justin Brown; George Sgouros; Wesley E Bolch; Eric C Frey
Journal:  Med Phys       Date:  2019-09-20       Impact factor: 4.071

6.  A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

Authors:  Abhinav K Jha; Brian Caffo; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-03-16       Impact factor: 3.609

7.  Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth.

Authors:  Abhinav K Jha; Na Song; Brian Caffo; Eric C Frey
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-04-13

8.  Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

9.  Factors affecting the repeatability of gamma camera calibration for quantitative imaging applications using a sealed source.

Authors:  N Anizan; H Wang; X C Zhou; R L Wahl; E C Frey
Journal:  Phys Med Biol       Date:  2015-01-16       Impact factor: 3.609

10.  Development of a 4D Digital Phantom for Tracer Kinetic Modeling and Analysis of Dynamic Perfusion PET and SPECT Simulation Studies.

Authors:  George S K Fung; Takahiro Higuchi; Min Jae Park; W Paul Segars; Benjamin M W Tsui
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2011-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.