Literature DB >> 30460462

Minimal under-correction gives better outcomes following total knee arthroplasty in severe varus knees-myth or reality?-analysis of one hundred sixty two knees with varus greater than fifteen degrees.

Raja Bhaskara Rajasekaran1, Dhanasekara Raja Palanisami2, Rajkumar Natesan2, Shanmuganathan Rajasekaran2.   

Abstract

PURPOSE OF THE STUDY: To document and compare the functional outcome of neutral alignment and under-correction after total knee arthroplasty (TKA) in severe varus knees of more than 15° at three and 12 months post-surgery.
MATERIALS AND METHODS: One hundred twenty-four consecutive patients (163 TKAs) of an average age of 61.9 years (52-79) with a pre-operative varus more than 15° were managed with jig-based TKA. Based on the post-operative mechanical femorotibial alignment (FTMA), they were categorised into three groups, namely neutral (180 + 3°), mild varus (173° to 176°) and severe varus (172° and below). The outcomes of these three groups were assessed at three and 12 months by the Oxford knee score and the WOMAC score were calculated and co-related to the extent of correction.
RESULTS: At three months, knees in the mild varus group (n = 88) had the best results with an Oxford knee score of 41.76 + 1.44 and a WOMAC score of 19.29 + 2.93 compared to the severe varus group and the neutral alignment group which had Oxford knee scores (OKS) of 37.43 + 2.51 and 31.91 + 3.51 and WOMAC scores of 22.57 + 1.51 and 24.46 + 4.15 respectively. However at 12 months, knees in all the groups (neutral, mild varus, severe varus) had similar good functional outcomes with OKS of 39.08 + 1.68, 39.24 + 1.88, 39.29 + 1.11 and WOMAC scores of 17.42 + 2.15, 16.48 + 2.11, 16.14 + 1.21 respectively. A scatter plot done for post-operative FTMA and the functional outcome score for both scores showed a bell curve with the best outcome corresponding to a FTMA of 175° at 3 months and equal distribution for both scores at 12 months.
CONCLUSION: The results of our study showed that minimal under-correction gave superior functional outcomes at three months. But this advantage was temporary and both, under-correction and neutral alignment achieved equally good outcomes at one year. Considering the increased prosthesis longevity associated with neutral alignment, we propose that neutral alignment must be aimed for during TKA for knees with severe varus. STUDY
DESIGN: Prospective study.

Entities:  

Keywords:  Neutral alignment; Oxford knee score; Total knee arthroplasty; Under-correction; WOMAC

Year:  2018        PMID: 30460462     DOI: 10.1007/s00264-018-4240-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  Polyethylene contact stresses, articular congruity, and knee alignment.

Authors:  D D D'Lima; P C Chen; C W Colwell
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

2.  Alignment in total knee replacement.

Authors:  D S Hungerford
Journal:  Instr Course Lect       Date:  1995

3.  Polycentric total knee arthroplasty. A ten-year follow-up study.

Authors:  D G Lewallen; R S Bryan; L F Peterson
Journal:  J Bone Joint Surg Am       Date:  1984-10       Impact factor: 5.284

4.  Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category?

Authors:  Stephen M Howell; Stacey J Howell; Kyle T Kuznik; Joe Cohen; Maury L Hull
Journal:  Clin Orthop Relat Res       Date:  2012-09-21       Impact factor: 4.176

5.  Health related quality of life outcomes after total hip and knee arthroplasties in a community based population.

Authors:  C A Jones; D C Voaklander; D W Johnston; M E Suarez-Almazor
Journal:  J Rheumatol       Date:  2000-07       Impact factor: 4.666

6.  Differences in limb alignment and femoral mechanical-anatomical angles using two dimension versus three dimension radiographic imaging.

Authors:  Frédéric Sailhan; Louis Jacob; Moussa Hamadouche
Journal:  Int Orthop       Date:  2017-02-24       Impact factor: 3.075

Review 7.  Total knee arthroplasty in the varus knee: tips and tricks.

Authors:  Roberto Rossi; Umberto Cottino; Matteo Bruzzone; Federico Dettoni; Davide Edoardo Bonasia; Federica Rosso
Journal:  Int Orthop       Date:  2018-08-23       Impact factor: 3.075

8.  Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty.

Authors:  Peter F Choong; Michelle M Dowsey; James D Stoney
Journal:  J Arthroplasty       Date:  2008-05-19       Impact factor: 4.757

9.  Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees.

Authors:  Luc Vanlommel; Jan Vanlommel; Steven Claes; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-04       Impact factor: 4.342

10.  Influence of the post-operative axis on the clinical results of total knee replacement for severe varus deformities: does a slight residual varus improve the results?

Authors:  Dominique Saragaglia; Loïc Sigwalt; Ramsay Refaie; Brice Rubens-Duval; Gabriel Lateur; Régis Pailhé
Journal:  Int Orthop       Date:  2018-08-14       Impact factor: 3.075

View more
  5 in total

1.  The forgotten joint score in total and unicompartmental knee arthroplasty: a prospective cohort study.

Authors:  Geert Peersman; Jeroen Verhaegen; Barbara Favier
Journal:  Int Orthop       Date:  2019-05-21       Impact factor: 3.075

2.  Indian orthopaedics: the past, present, and future.

Authors:  Ashok S Gavaskar; C Mauffrey; S Babhulkar
Journal:  Int Orthop       Date:  2020-01-23       Impact factor: 3.075

3.  When to Use a Condylar Constrained Insert in Non-Stemmed Posterior-Stabilized Total Knee Arthroplasty.

Authors:  Satit Thiengwittayaporn; Natthapong Hongku; Umaporn Uawisetwathana; Pichai Sansawat
Journal:  Clin Orthop Surg       Date:  2020-07-03

Review 4.  Comparison of Outcomes After Total Knee Arthroplasty Involving Postoperative Neutral or Residual Mild Varus Alignment: A Systematic Review and Meta-analysis.

Authors:  Xu-Feng Wan; Yang Yang; Duan Wang; Hong Xu; Chao Huang; Zong-Ke Zhou; Jin Xu
Journal:  Orthop Surg       Date:  2021-12-13       Impact factor: 2.071

5.  Slight femoral under-correction versus neutral alignment in total knee arthroplasty with preoperative varus knees: a comparative study.

Authors:  Kai Lei; Li-Ming Liu; Peng-Fei Yang; Ran Xiong; De-Jie Fu; Liu Yang; Lin Guo
Journal:  Arthroplasty       Date:  2022-01-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.