Literature DB >> 21784988

The impact of baseline artery diameter on flow-mediated vasodilation: a comparison of brachial and radial artery responses to matched levels of shear stress.

F Jazuli1, K E Pyke.   

Abstract

An inverse relationship between baseline artery diameter (BAD) and flow-mediated vasodilation (FMD) has been identified using reactive hyperemia (RH) to create a shear stress (SS) stimulus in human conduit arteries. However, RH creates a SS stimulus that is inversely related to BAD. The purpose of this study was to compare FMD in response to matched levels of SS in two differently sized upper limb arteries [brachial (BA) and radial (RA) artery]. With the use of exercise, three distinct, shear rate (SR) stimuli were created (SR = blood velocity/vessel diameter; estimate of SS) in the RA and BA. Artery diameter and mean blood velocity were assessed with echo and Doppler ultrasound in 15 healthy male subjects (19-25 yr). Data are means ± SE. Subjects performed 6 min of adductor pollicis and handgrip exercise to increase SR in the RA and BA, respectively. Exercise intensity was modulated to achieve uniformity in SR between arteries. The three distinct SR levels were as follows: steady-state exercise 39.8 ± 0.6, 57.3 ± 0.7, and 72.4 ± 1.2 s(-1) (P < 0.001). %FMD and AbsFMD (mm) at the end of exercise were greater in the RA vs. the BA at each shear level [at the highest level: RA = 15.7 ± 1.5%, BA = 5.4 ± 0.8% (P < 0.001)]. The mean slope of the within-subject SR-%FMD regression line was greater in the RA (RA = 0.33 ± 0.04, BA = 0.13 ± 0.02, P < 0.001), and a strong within-subjects relationship between %FMD and SR was observed in both arteries (RA: r(2) = 0.92 ± 0.02; BA: r(2) = 0.90 ± 0.03). Within the RA, there was a significant relationship between baseline diameter and %FMD; however, this relationship was not present in the BA (RA: r(2) = 0.76, P < 0.001; BA: r(2) = 0.03, P = 0.541). These findings suggest that the response to SS is not uniform across differently sized vessels, which is in agreement with previous studies.

Entities:  

Mesh:

Year:  2011        PMID: 21784988     DOI: 10.1152/ajpheart.00487.2011

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  14 in total

1.  Effects of dynamic shear and transmural pressure on wall shear stress sensitivity in collecting lymphatic vessels.

Authors:  Jeffrey A Kornuta; Zhanna Nepiyushchikh; Olga Y Gasheva; Anish Mukherjee; David C Zawieja; J Brandon Dixon
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2015-09-02       Impact factor: 3.619

2.  Impaired brachial artery endothelial function in young healthy women following an acute painful stimulus.

Authors:  T J King; H Lemke; A D Green; D A Tripp; V J Poitras; B J Gurd; K E Pyke
Journal:  Eur J Appl Physiol       Date:  2015-03-01       Impact factor: 3.078

3.  The influence of vitamin C on the interaction between acute mental stress and endothelial function.

Authors:  Meghan D Plotnick; Katrina A D'Urzo; Brendon J Gurd; Kyra E Pyke
Journal:  Eur J Appl Physiol       Date:  2017-06-13       Impact factor: 3.078

4.  The impact of handgrip exercise duty cycle on brachial artery flow-mediated dilation.

Authors:  Trevor J King; David J Slattery; Kyra E Pyke
Journal:  Eur J Appl Physiol       Date:  2013-02-24       Impact factor: 3.078

5.  Reproducible improvement in endothelial function following two separate periods of high-intensity interval training in young men.

Authors:  J S Williams; M Del Giudice; B J Gurd; K E Pyke
Journal:  J Appl Physiol (1985)       Date:  2020-08-13

Review 6.  Flow-mediated dilation stimulated by sustained increases in shear stress: a useful tool for assessing endothelial function in humans?

Authors:  Joshua C Tremblay; Kyra E Pyke
Journal:  Am J Physiol Heart Circ Physiol       Date:  2017-11-22       Impact factor: 4.733

7.  Examining the acute effects of retrograde versus low mean shear rate on flow-mediated dilation.

Authors:  Joshua C Tremblay; Arman S Grewal; Kyra E Pyke
Journal:  J Appl Physiol (1985)       Date:  2019-03-07

8.  Ramp and step increases in shear stress result in a similar magnitude of brachial artery flow-mediated dilation.

Authors:  Joshua C Tremblay; Jennifer S Williams; Kyra E Pyke
Journal:  Eur J Appl Physiol       Date:  2019-01-02       Impact factor: 3.078

9.  Can a combination of handgrip exercise and prolonged forearm occlusion elicit a maximal brachial artery FMD response?

Authors:  Jennifer Ku; Alana McEvoy; Kyra E Pyke
Journal:  Eur J Appl Physiol       Date:  2014-03-13       Impact factor: 3.078

10.  Evidence of sex differences in the acute impact of oscillatory shear stress on endothelial function.

Authors:  Joshua C Tremblay; Taylor V Stimpson; Kyra E Pyke
Journal:  J Appl Physiol (1985)       Date:  2018-11-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.