Abstract

PURPOSE: We present a method to correct respiratory motion blurring in PET/CT imaging using internal-external (INTEX) motion correlation. The internal motion of a known tumor is derived from respiratory-gated PET images; this internal motion is then correlated with external respiratory signals to determine the complete information of tumor motion during the scan.
METHODS: For each PET/CT data, PET listmode data were phase-gated into five bins and reconstructed. The centroid of a targeted tumor in each bin was determined and correlated with the corresponding mean displacement of externally monitored respiratory motion signal. Based on this correlation, the external motion signal was converted into internal tumor motion information in the superior-inferior direction. Then, the PET listmode data were binned sequentially to multiple 1-s sinograms. According to the converted internal tumor motion signal, each 1-s sinogram was registered to a reference frame, which best matched the helical CT attenuation map based on consistency conditions. The registered sinograms were summed and reconstructed to form an image, corrected for the motion of the specific tumor. In this study, the proposed INTEX method was evaluated with phantom and patient studies in terms of tracer concentration and volume.
RESULTS: The INTEX method effectively recovered the tracer concentration to the level of the stationary scan data in the phantom experiment. In the patient study, the INTEX method yielded a (17 +/- 22)% tumor volume decrease and a (10 +/- 10)% tumor SUVmax increase compared to non-gated images.
CONCLUSIONS: The proposed INTEX method reduces respiratory motion degradation of PET tumor quantification and delineation in an effective manner. This can be used to improve the assessment of response to therapy for a known tumor by minimizing residual motion and matching the attenuation correction, without increasing image noise.

Entities:  

Mesh:

Year:  2011        PMID: 21776808      PMCID: PMC3107832          DOI: 10.1118/1.3582692

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  43 in total

1.  An analytic study of the effects of attenuation on tumor detection in whole-body PET oncology imaging.

Authors:  Chuanyong Bai; Paul E Kinahan; David Brasse; Claude Comtat; David W Townsend; Carolyn C Meltzer; Victor Villemagne; Martin Charron; Michel Defrise
Journal:  J Nucl Med       Date:  2003-11       Impact factor: 10.057

2.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

3.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

4.  Reducing respiratory motion artifacts in positron emission tomography through retrospective stacking.

Authors:  Brian Thorndyke; Eduard Schreibmann; Albert Koong; Lei Xing
Journal:  Med Phys       Date:  2006-07       Impact factor: 4.071

5.  Postacquisition detection of tumor motion in the lung and upper abdomen using list-mode PET data: a feasibility study.

Authors:  Ralph A Bundschuh; Axel Martínez-Moeller; Markus Essler; María-José Martínez; Stephan G Nekolla; Sibylle I Ziegler; Markus Schwaiger
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

Review 6.  Literature-based recommendations for treatment planning and execution in high-dose radiotherapy for lung cancer.

Authors:  Suresh Senan; Dirk De Ruysscher; Philippe Giraud; René Mirimanoff; Volker Budach
Journal:  Radiother Oncol       Date:  2004-05       Impact factor: 6.280

7.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

8.  Retrospective data-driven respiratory gating for PET/CT.

Authors:  Paul J Schleyer; Michael J O'Doherty; Sally F Barrington; Paul K Marsden
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

9.  Single 20-second acquisition of deep-inspiration breath-hold PET/CT: clinical feasibility for lung cancer.

Authors:  Tatsuo Torizuka; Yasuo Tanizaki; Toshihiko Kanno; Masami Futatsubashi; Etsuji Yoshikawa; Hiroyuki Okada; Yasuomi Ouchi
Journal:  J Nucl Med       Date:  2009-09-16       Impact factor: 10.057

10.  Phase versus amplitude sorting of 4D-CT data.

Authors:  Nicole Wink; Christoph Panknin; Timothy D Solberg
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

View more
  17 in total

1.  Assessment of patient selection criteria for quantitative imaging with respiratory-gated positron emission tomography.

Authors:  Stephen R Bowen; Larry A Pierce; Adam M Alessio; Chi Liu; Scott D Wollenweber; Charles W Stearns; Paul E Kinahan
Journal:  J Med Imaging (Bellingham)       Date:  2014-09-24

2.  Higher-order singular value decomposition-based lung parcellation for breathing motion management.

Authors:  Samadrita Roy Chowdhury; Joyita Dutta
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-03

3.  Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction.

Authors:  Mary Germino; Richard E Carson
Journal:  Med Phys       Date:  2017-12-30       Impact factor: 4.071

Review 4.  Motion Correction and Its Impact on Absolute Myocardial Blood Flow Measures with PET.

Authors:  Marina Piccinelli; John R Votaw; Ernest V Garcia
Journal:  Curr Cardiol Rep       Date:  2018-03-24       Impact factor: 2.931

5.  Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study.

Authors:  S R Bowen; M J Nyflot; C Herrmann; C M Groh; J Meyer; S D Wollenweber; C W Stearns; P E Kinahan; G A Sandison
Journal:  Phys Med Biol       Date:  2015-04-17       Impact factor: 3.609

Review 6.  Improved Detection of Small Pulmonary Nodules Through Simultaneous MR/PET Imaging.

Authors:  Fernando E Boada; Thomas Koesters; Kai Tobias Block; Hersh Chandarana
Journal:  Magn Reson Imaging Clin N Am       Date:  2017-02-22       Impact factor: 2.266

7.  MRI Investigation of the Linkage Between Respiratory Motion of the Heart and Markers on Patient's Abdomen and Chest: Implications for Respiratory Amplitude Binning List-Mode PET and SPECT Studies.

Authors:  Paul Dasari; Karen Johnson; Joyoni Dey; Clifford Lindsay; Mohammed S Shazeeb; Joyeeta Mitra Mukherjee; Shaokuan Zheng; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2014-02-06       Impact factor: 1.679

Review 8.  Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging.

Authors:  Tzu C Lee; Adam M Alessio; Robert M Miyaoka; Paul E Kinahan
Journal:  Q J Nucl Med Mol Imaging       Date:  2015-11-17       Impact factor: 2.346

9.  List-mode reconstruction for the Biograph mCT with physics modeling and event-by-event motion correction.

Authors:  Xiao Jin; Chung Chan; Tim Mulnix; Vladimir Panin; Michael E Casey; Chi Liu; Richard E Carson
Journal:  Phys Med Biol       Date:  2013-07-29       Impact factor: 3.609

10.  Non-Rigid Event-by-Event Continuous Respiratory Motion Compensated List-Mode Reconstruction for PET.

Authors:  Chung Chan; John Onofrey; Yiqiang Jian; Mary Germino; Xenophon Papademetris; Richard E Carson; Chi Liu
Journal:  IEEE Trans Med Imaging       Date:  2017-10-10       Impact factor: 10.048

View more