Literature DB >> 19265207

Retrospective data-driven respiratory gating for PET/CT.

Paul J Schleyer1, Michael J O'Doherty, Sally F Barrington, Paul K Marsden.   

Abstract

Respiratory motion can adversely affect both PET and CT acquisitions. Respiratory gating allows an acquisition to be divided into a series of motion-reduced bins according to the respiratory signal, which is typically hardware acquired. In order that the effects of motion can potentially be corrected for, we have developed a novel, automatic, data-driven gating method which retrospectively derives the respiratory signal from the acquired PET and CT data. PET data are acquired in listmode and analysed in sinogram space, and CT data are acquired in cine mode and analysed in image space. Spectral analysis is used to identify regions within the CT and PET data which are subject to respiratory motion, and the variation of counts within these regions is used to estimate the respiratory signal. Amplitude binning is then used to create motion-reduced PET and CT frames. The method was demonstrated with four patient datasets acquired on a 4-slice PET/CT system. To assess the accuracy of the data-derived respiratory signal, a hardware-based signal was acquired for comparison. Data-driven gating was successfully performed on PET and CT datasets for all four patients. Gated images demonstrated respiratory motion throughout the bin sequences for all PET and CT series, and image analysis and direct comparison of the traces derived from the data-driven method with the hardware-acquired traces indicated accurate recovery of the respiratory signal.

Entities:  

Mesh:

Year:  2009        PMID: 19265207     DOI: 10.1088/0031-9155/54/7/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Byungchul Cho; Youngho Seo; Paul J Keall
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Respiratory motion correction for quantitative PET/CT using all detected events with internal-external motion correlation.

Authors:  Chi Liu; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

Review 3.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

4.  Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211.

Authors:  Mathieu Hatt; John A Lee; Charles R Schmidtlein; Issam El Naqa; Curtis Caldwell; Elisabetta De Bernardi; Wei Lu; Shiva Das; Xavier Geets; Vincent Gregoire; Robert Jeraj; Michael P MacManus; Osama R Mawlawi; Ursula Nestle; Andrei B Pugachev; Heiko Schöder; Tony Shepherd; Emiliano Spezi; Dimitris Visvikis; Habib Zaidi; Assen S Kirov
Journal:  Med Phys       Date:  2017-05-18       Impact factor: 4.071

5.  Comparison of the clinical performance of upper abdominal PET/DCE-MRI with and without concurrent respiratory motion correction (MoCo).

Authors:  Onofrio A Catalano; Lale Umutlu; Niccolo Fuin; Matthew Louis Hibert; Michele Scipioni; Stefano Pedemonte; Mark Vangel; Andreea Maria Catana; Ken Herrmann; Felix Nensa; David Groshar; Umar Mahmood; Bruce R Rosen; Ciprian Catana
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-07-11       Impact factor: 9.236

6.  Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging.

Authors:  Matthew J Nyflot; Tzu-Cheng Lee; Adam M Alessio; Scott D Wollenweber; Charles W Stearns; Stephen R Bowen; Paul E Kinahan
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

7.  Data-driven respiratory motion tracking and compensation in CZT cameras: a comprehensive analysis of phantom and human images.

Authors:  Chi-Lun Ko; Yen-Wen Wu; Mei-Fang Cheng; Ruoh-Fang Yen; Wen-Chau Wu; Kai-Yuan Tzen
Journal:  J Nucl Cardiol       Date:  2014-08-14       Impact factor: 5.952

8.  The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Samuel R Mazin; Edward E Graves; Paul J Keall
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

9.  The impact of data-driven respiratory gating in clinical F-18 FDG PET/CT: comparison of free breathing and deep-expiration breath-hold CT protocol.

Authors:  Seo Young Kang; Byung Seok Moon; Hye Ok Kim; Hai-Jeon Yoon; Bom Sahn Kim
Journal:  Ann Nucl Med       Date:  2021-01-15       Impact factor: 2.668

10.  Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions.

Authors:  Abdel K Tahari; Martin A Lodge; Richard L Wahl
Journal:  J Med Imaging Radiat Oncol       Date:  2014-01-20       Impact factor: 1.735

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.