Literature DB >> 16266119

Examination of dosimetry accuracy as a function of seed detection rate in permanent prostate brachytherapy.

Yi Su1, Brian J Davis, Michael G Herman, Armando Manduca, Richard A Robb.   

Abstract

The variation of permanent prostate brachytherapy dosimetry as a function of seed detection rates was investigated for I125 implants with seed activities commonly employed in contemporary practice. Post-implant imaging and radiation dosimetry data from nine patients who underwent PPB served as the basis of this simulation study. One-thousand random configurations of detected seeds were generated for each patient dataset using various seed detection levels from 30% to 99%. Dose parameters, including D90, were computed for each configuration and compared with the actual dosimetry data. A total of 108 000 complete sets of post-PPB dose volume statistics were computed. The results demonstrated that although the average D90 differed from the true value by less than 5% when 70% or more seeds were identified, the D90 of an individual case could deviate up to 13%. The 95% confidence interval (CI) of estimated D90 values differ by less than 5% from the actual value when 95% or more seeds are detected, or approximately a 7 Gy difference in the D90 value for a prescription dose of 144 Gy. Estimated target volume dose parameters tended to decrease with reduced seed detection rates. The most variable dose parameter was the prostate V100 in absolute scale while the urethral V100 was most variable in a relative sense. Based on this comprehensive simulation study, it is suggested that 95% or more seeds need to be localized in order to provide an accurate estimation of dose parameters for contemporary iodine 125 permanent prostate brachytherapy.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16266119     DOI: 10.1118/1.2012789

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  TOMOSYNTHESIS-BASED RADIOACTIVE SEED LOCALIZATION IN PROSTATE BRACHYTHERAPY USING MODIFIED DISTANCE MAP IMAGES.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Jerry L Prince; Gabor Fichtinger
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008-05-14

3.  Segmentation of iodine brachytherapy implants in fluoroscopy.

Authors:  Eric Moult; Gabor Fichtinger; W James Morris; Septimiu E Salcudean; Ehsan Dehghan; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-03-25       Impact factor: 2.924

4.  Intraoperative segmentation of iodine and palladium radioactive sources in C-arm images.

Authors:  Chiara Amat di San Filippo; Gabor Fichtinger; William James Morris; Septimiu E Salcudean; Ehsan Dehghan; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-07       Impact factor: 2.924

5.  Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: a pilot ex vivo study.

Authors:  Mohammad Mehrmohammadi; Azra Alizad; Randall R Kinnick; Brian J Davis; Mostafa Fatemi
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

6.  Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm.

Authors:  A Jain; A Deguet; I Iordachita; G Chintalapani; S Vikal; J Blevins; Y Le; E Armour; C Burdette; D Song; G Fichtinger
Journal:  Med Image Anal       Date:  2010-08-14       Impact factor: 8.545

7.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

8.  Investigating the dosimetric and tumor control consequences of prostate seed loss and migration.

Authors:  Courtney Knaup; Panayiotis Mavroidis; Carlos Esquivel; Sotirios Stathakis; Gregory Swanson; Dimos Baltas; Nikos Papanikolaou
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

9.  Vibro-acoustography imaging of permanent prostate brachytherapy seeds in an excised human prostate--preliminary results and technical feasibility.

Authors:  F G Mitri; B J Davis; M W Urban; A Alizad; J F Greenleaf; G H Lischer; T M Wilson; M Fatemi
Journal:  Ultrasonics       Date:  2008-10-30       Impact factor: 2.890