FTRAC--a robust fluoroscope tracking fiducial.

Ameet Kumar Jain1, Tabish Mustafa, Yu Zhou, Clif Burdette, Gregory S Chirikjian, Gabor Fichtinger.   

Abstract

C-arm fluoroscopy is ubiquitous in contemporary surgery, but it lacks the ability to accurately reconstruct three-dimensional (3D) information. A major obstacle in fluoroscopic reconstruction is discerning the pose of the x-ray image, in 3D space. Optical/magnetic trackers tend to be prohibitively expensive, intrusive and cumbersome in many applications. We present single-image-based fluoroscope tracking (FTRAC) with the use of an external radiographic fiducial consisting of a mathematically optimized set of ellipses, lines, and points. This is an improvement over contemporary fiducials, which use only points. The fiducial encodes six degrees of freedom in a single image by creating a unique view from any direction. A nonlinear optimizer can rapidly compute the pose of the fiducial using this image. The current embodiment has salient attributes: small dimensions (3 x 3 x 5 cm); need not be close to the anatomy of interest; and accurately segmentable. We tested the fiducial and the pose recovery method on synthetic data and also experimentally on a precisely machined mechanical phantom. Pose recovery in phantom experiments had an accuracy of 0.56 mm in translation and 0.33 degrees in orientation. Object reconstruction had a mean error of 0.53 mm with 0.16 mm STD. The method offers accuracies similar to commercial tracking systems, and appears to be sufficiently robust for intraoperative quantitative C-arm fluoroscopy. Simulation experiments indicate that the size can be further reduced to 1 x 1 X 2 cm, with only a marginal drop in accuracy.

Entities:  

Mesh:

Year:  2005        PMID: 16279072     DOI: 10.1118/1.2047782

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  C-arm rotation encoding with accelerometers.

Authors:  Victor Grzeda; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-04-10       Impact factor: 2.924

3.  INTENSITY-BASED REGISTRATION OF PROSTATE BRACHYTHERAPY IMPLANTS AND ULTRASOUND.

Authors:  Z Karimaghaloo; G Fichtinger; D G Gobbi; E C Burdette; R N Rohling; P Abolmaesumi
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008-06-13

4.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

5.  CTREC: C-arm Tracking and Reconstruction using Elliptic Curves.

Authors:  Gouthami Chintalapani; Ameet K Jain; David H Burkhardt; Jerry L Prince; Gabor Fichtinger
Journal:  Conf Comput Vis Pattern Recognit Workshops       Date:  2008-06

6.  Prostate brachytherapy seed localization with Gaussian blurring and camera self-calibration.

Authors:  Junghoon Lee; Xiaofeng Liu; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

7.  C-arm angle measurement with accelerometer for brachytherapy: an accuracy study.

Authors:  Thomas Wolff; Andras Lasso; Markus Eblenkamp; Erich Wintermantel; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-03       Impact factor: 2.924

8.  Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy.

Authors:  Nikolas Leßmann; Daniel Drömann; Alexander Schlaefer
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-26       Impact factor: 2.924

9.  Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Danny Y Song; Everette C Burdette; Jerry L Prince; Gabor Fichtinger
Journal:  IEEE Trans Med Imaging       Date:  2009-07-14       Impact factor: 10.048

10.  Prostate brachytherapy seed localization using a mobile c-arm without tracking.

Authors:  Maria S Ayad; Junghoon Lee; Jerry L Prince; Gabor Fichtinger
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-03-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.