Abstract

Accuracies of a point-based and an intensity-based fluoroscopic methods of assessing patella tracking were determined by comparing the pattern of patellar motion with respect to orientation (flexion, internal rotation, and lateral tilt) and translation (lateral, proximal, and anterior) with the pattern of patellar motion measured using Roentgen stereophotogrammetric analysis in three cadaver knee specimens. Each pose in the patellar motion could be obtained from single as well as multiple calibrated fluoroscopic images. The errors using the intensity-based method were slightly higher than those of the point-based method, but they appear to be sufficiently low to detect clinically significant differences in patellar kinematics.

Entities:  

Mesh:

Year:  2004        PMID: 15450227     DOI: 10.1016/j.media.2004.06.011

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  8 in total

1.  Physiological sagittal plane patellar kinematics during dynamic deep knee flexion.

Authors:  Satoshi Hamai; Nicholas J Dunbar; Taka-aki Moro-oka; Hiromasa Miura; Yukihide Iwamoto; Scott A Banks
Journal:  Int Orthop       Date:  2013-06-19       Impact factor: 3.075

2.  Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing.

Authors:  C Belvedere; A Ensini; A Leardini; V Dedda; A Feliciangeli; F Cenni; A Timoncini; P Barbadoro; S Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-10       Impact factor: 4.342

Review 3.  MRI of weight bearing and movement.

Authors:  L M Shapiro; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2011-11-17       Impact factor: 6.576

4.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

5.  Augmented reality and artificial intelligence-assisted surgical navigation: Technique and cadaveric feasibility study.

Authors:  Kris B Siemionow; Karina M Katchko; Paul Lewicki; Cristian J Luciano
Journal:  J Craniovertebr Junction Spine       Date:  2020-06-05

6.  Feasibility of using real-time MRI to measure joint kinematics in 1.5T and open-bore 0.5T systems.

Authors:  Christine E Draper; Juan M Santos; Lampros C Kourtis; Thor F Besier; Michael Fredericson; Gary S Beaupre; Garry E Gold; Scott L Delp
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

7.  Patellar tracking during total knee arthroplasty: an in vitro feasibility study.

Authors:  C Belvedere; F Catani; A Ensini; J L Moctezuma de la Barrera; A Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-04-13       Impact factor: 4.114

8.  A new 2D-3D registration gold-standard dataset for the hip joint based on uncertainty modeling.

Authors:  Fabio D'Isidoro; Christophe Chênes; Stephen J Ferguson; Jérôme Schmid
Journal:  Med Phys       Date:  2021-08-17       Impact factor: 4.506

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.