Literature DB >> 21769981

Resolving arterial phase and temporal enhancement characteristics in DCE MRM at high spatial resolution with TWIST acquisition.

Karl-Heinz Herrmann1, Pascal A Baltzer, Matthias Dietzel, Ines Krumbein, Christian Geppert, Werner A Kaiser, Jürgen R Reichenbach.   

Abstract

PURPOSE: To investigate the potential of a view-sharing 3D fast gradient-echo sequence using pseudo random trajectories (TWIST) to achieve very short acquisition times with high in-plane resolution and good volume coverage and its application to dynamic contrast-enhanced (DCE) breast magnetic resonance imaging (MRI).
MATERIALS AND METHODS: Two versions of a 3D fast gradient echo TWIST sequence were implemented and applied to patients: First, an ultrafast TWIST acquisition (TA = 5.7 sec) in combination with a routine DCE MRM protocol to allow the extraction of arterial input functions and to resolve the first pass of the contrast agent. Second, a dynamic full coverage TWIST DCE acquisition (TA = 10.6 sec) in a repeat examination, replacing the routine DCE MRM sequence.
RESULTS: The ultrafast acquisition enabled extraction of arterial input functions and the monitoring of the contrast agent's first pass through vessels and lesions. The dynamic full coverage TWIST acquisition captured the initial dynamic slope of the signal time curve of lesions accurately, in contrast to the routine protocol.
CONCLUSION: TWIST acquisitions proved very robust and offer high flexibility in protocol timing. The ultrafast protocol achieved 5.7 seconds time resolution with good image quality and can be combined with any established routine protocol. The full dynamics TWIST DCE protocol offers improved time resolution of the CE dynamic time-course and closely matches the image quality of the routine protocol.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21769981     DOI: 10.1002/jmri.22689

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  17 in total

Review 1.  Review of key concepts in magnetic resonance physics.

Authors:  Michael M Moore; Taylor Chung
Journal:  Pediatr Radiol       Date:  2017-04-13

2.  Influence of scan duration on the estimation of pharmacokinetic parameters for breast lesions: a study based on CAIPIRINHA-Dixon-TWIST-VIBE technique.

Authors:  Wen Hao; Bin Zhao; Guangbin Wang; Cuiyan Wang; Hui Liu
Journal:  Eur Radiol       Date:  2014-10-17       Impact factor: 5.315

3.  Intrahepatic dynamic contrast MR lymphangiography: initial experience with a new technique for the assessment of liver lymphatics.

Authors:  David M Biko; Christopher L Smith; Hansel J Otero; David Saul; Ammie M White; Aaron DeWitt; Andrew C Glatz; David A Piccoli; Petar Mamula; Jonathan J Rome; Yoav Dori
Journal:  Eur Radiol       Date:  2019-03-18       Impact factor: 5.315

Review 4.  Body MR angiography in children: how we do it.

Authors:  Rajesh Krishnamurthy; LaDonna Malone; Karen Lyons; Pamela Ketwaroo; Nicholas Dodd; Daniel Ashton
Journal:  Pediatr Radiol       Date:  2016-05-26

5.  Novel High Spatiotemporal Resolution Versus Standard-of-Care Dynamic Contrast-Enhanced Breast MRI: Comparison of Image Quality.

Authors:  Courtney K Morrison; Leah C Henze Bancroft; Wendy B DeMartini; James H Holmes; Kang Wang; Ryan J Bosca; Frank R Korosec; Roberta M Strigel
Journal:  Invest Radiol       Date:  2017-04       Impact factor: 6.016

6.  A novel framework for evaluating the image accuracy of dynamic MRI and the application on accelerated breast DCE MRI.

Authors:  Yuan Le; Marcel Dominik Nickel; Stephan Kannengiesser; Berthold Kiefer; Bruce Spottiswoode; Brian Dale; Victor Soon; Chen Lin
Journal:  MAGMA       Date:  2017-09-11       Impact factor: 2.310

7.  DIfferential Subsampling with Cartesian Ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging.

Authors:  Manojkumar Saranathan; Dan W Rettmann; Brian A Hargreaves; Sharon E Clarke; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2012-02-14       Impact factor: 4.813

8.  Differentiation between subcentimeter carcinomas and benign lesions using kinetic parameters derived from ultrafast dynamic contrast-enhanced breast MRI.

Authors:  Natsuko Onishi; Meredith Sadinski; Peter Gibbs; Katherine M Gallagher; Mary C Hughes; Eun Sook Ko; Brittany Z Dashevsky; Dattesh D Shanbhag; Maggie M Fung; Theodore M Hunt; Danny F Martinez; Amita Shukla-Dave; Elizabeth A Morris; Elizabeth J Sutton
Journal:  Eur Radiol       Date:  2019-08-29       Impact factor: 5.315

9.  3D Cartesian MRI with compressed sensing and variable view sharing using complementary poisson-disc sampling.

Authors:  Evan Levine; Bruce Daniel; Shreyas Vasanawala; Brian Hargreaves; Manojkumar Saranathan
Journal:  Magn Reson Med       Date:  2016-04-21       Impact factor: 4.668

10.  Dynamic contrast-enhanced magnetic resonance imaging measurement of renal function in patients undergoing partial nephrectomy: preliminary experience.

Authors:  Stella K Kang; William C Huang; Samson Wong; Jeff L Zhang; Michael D Stifelman; Mary T Bruno; James S Babb; Vivian S Lee; Hersh Chandarana
Journal:  Invest Radiol       Date:  2013-10       Impact factor: 6.016

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.