David M Biko1, Christopher L Smith2, Hansel J Otero3, David Saul3, Ammie M White3, Aaron DeWitt2, Andrew C Glatz2, David A Piccoli4, Petar Mamula4, Jonathan J Rome2, Yoav Dori2. 1. Department of Radiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, 3401 Civic Center Blvd, Philadelphia, PA, 19104, USA. bikod@email.chop.edu. 2. Division of Cardiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, 3401 Civic Center Blvd, Philadelphia, PA, 19104, USA. 3. Department of Radiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, 3401 Civic Center Blvd, Philadelphia, PA, 19104, USA. 4. Division of Gastroenterology, Hepatology, and Nutrition, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, 3401 Civic Center Blvd, Philadelphia, PA, 19104, USA.
Abstract
OBJECTIVES: To describe the technique and report on our initial experience with the use of intrahepatic dynamic contrast magnetic resonance lymphangiography (IH-DCMRL) for evaluation of the lymphatics in patients with hepatic lymphatic flow disorders. METHODS: This is a retrospective review of the imaging and clinical findings in six consecutive patients undergoing IH-DCMRL. The technique involves injection of a gadolinium contrast agent into the intrahepatic lymphatic ducts followed by imaging of the abdomen and chest with both heavily T2-weighted imaging and dynamic time-resolved imaging. RESULTS: In six consecutive patients, IH-DCMRL was technically successful. There were four patients with protein-losing enteropathy (PLE) and two with ascites in this study. In the four patients with PLE, IH-DCMRL demonstrated hepatoduodenal connections with leak of contrast into the duodenal lumen not seen by conventional lymphangiography. In one patient with ascites, IH-DCMRL demonstrated lymphatic leakage into the peritoneal cavity not seen by intranodal lymphangiography. In the second patient with ascites, retrograde lymphatic perfusion of mesenteric lymphatic networks and nodes was seen. Venous contamination was seen in two patients. No biliary contamination was identified. There were no short-term complications. CONCLUSIONS: IH-DCMRL is a cross-sectional technique which successfully evaluated hepatic lymphatic flow disorders and warrants further investigation. KEY POINTS: • Intrahepatic dynamic contrast magnetic resonance lymphangiography (IH-DCMRL) is a new imaging technique to evaluate hepatic lymphatic flow disorders such as protein-losing enteropathy. • In comparison to conventional liver lymphangiography, IH-DCMRL offers a 3D imaging technique and better distal lymphatic contrast distribution and does not use ionizing radiation.
OBJECTIVES: To describe the technique and report on our initial experience with the use of intrahepatic dynamic contrast magnetic resonance lymphangiography (IH-DCMRL) for evaluation of the lymphatics in patients with hepatic lymphatic flow disorders. METHODS: This is a retrospective review of the imaging and clinical findings in six consecutive patients undergoing IH-DCMRL. The technique involves injection of a gadolinium contrast agent into the intrahepatic lymphatic ducts followed by imaging of the abdomen and chest with both heavily T2-weighted imaging and dynamic time-resolved imaging. RESULTS: In six consecutive patients, IH-DCMRL was technically successful. There were four patients with protein-losing enteropathy (PLE) and two with ascites in this study. In the four patients with PLE, IH-DCMRL demonstrated hepatoduodenal connections with leak of contrast into the duodenal lumen not seen by conventional lymphangiography. In one patient with ascites, IH-DCMRL demonstrated lymphatic leakage into the peritoneal cavity not seen by intranodal lymphangiography. In the second patient with ascites, retrograde lymphatic perfusion of mesenteric lymphatic networks and nodes was seen. Venous contamination was seen in two patients. No biliary contamination was identified. There were no short-term complications. CONCLUSIONS: IH-DCMRL is a cross-sectional technique which successfully evaluated hepatic lymphatic flow disorders and warrants further investigation. KEY POINTS: • Intrahepatic dynamic contrast magnetic resonance lymphangiography (IH-DCMRL) is a new imaging technique to evaluate hepatic lymphatic flow disorders such as protein-losing enteropathy. • In comparison to conventional liver lymphangiography, IH-DCMRL offers a 3D imaging technique and better distal lymphatic contrast distribution and does not use ionizing radiation.
Entities:
Keywords:
Lymphatic system; Magnetic resonance imaging; Protein-losing enteropathies
Authors: Maxim Itkin; David A Piccoli; Gregory Nadolski; Jack Rychik; Aaron DeWitt; Erin Pinto; Jonathan Rome; Yoav Dori Journal: J Am Coll Cardiol Date: 2017-06-20 Impact factor: 24.094
Authors: Karl-Heinz Herrmann; Pascal A Baltzer; Matthias Dietzel; Ines Krumbein; Christian Geppert; Werner A Kaiser; Jürgen R Reichenbach Journal: J Magn Reson Imaging Date: 2011-07-18 Impact factor: 4.813
Authors: Christian A Barrera; Teresa Victoria; Fernando A Escobar; Ganesh Krishnamurthy; Christopher L Smith; Julie S Moldenhauer; David M Biko Journal: Pediatr Radiol Date: 2020-11-30
Authors: Karen I Ramirez-Suarez; Luis Octavio Tierradentro-García; David M Biko; Hansel J Otero; Ammie M White; Yoav Dori; Christopher L Smith; Seth Vatsky; Jordan B Rapp Journal: Pediatr Radiol Date: 2022-07-16
Authors: Jefferson N Brownell; David M Biko; Petar Mamula; Ganesh Krishnamurthy; Fernando Escobar; Abhay Srinivasan; Pablo Laje; David A Piccoli; Erin Pinto; Christopher L Smith; Yoav Dori Journal: J Pediatr Gastroenterol Nutr Date: 2022-01-01 Impact factor: 3.288
Authors: Mandi Liu; Christopher L Smith; David M Biko; Dong Li; Erin Pinto; Nora O'Connor; Cara Skraban; Elaine H Zackai; Hakon Hakonarson; Yoav Dori; Sarah E Sheppard Journal: Eur J Hum Genet Date: 2022-05-24 Impact factor: 5.351
Authors: Bethan A Lemley; Dave M Biko; Aaron G Dewitt; Andrew C Glatz; David J Goldberg; Madhumitha Saravanan; Michael L O'Byrne; Erin Pinto; Chitra Ravishankar; Jonathan J Rome; Christopher L Smith; Yoav Dori Journal: J Am Heart Assoc Date: 2021-09-25 Impact factor: 5.501
Authors: Christopher L Smith; Mandi Liu; Madhumitha Saravanan; Aaron G Dewitt; David M Biko; Erin M Pinto; Fernando A Escobar; Ganesh Krishnamurthy; Jefferson N Brownell; Petar Mamula; Andrew C Glatz; Matthew J Gillespie; Michael L O'Byrne; Chitra Ravishankar; Jonathan J Rome; Yoav Dori Journal: Eur Radiol Date: 2021-06-24 Impact factor: 5.315