Literature DB >> 21769442

Role of 'low cost Indian implants' in our practice: our experience with 1,572 pedicle screws.

Saurabh Rawall1, Kapil Mohan, Premick Nagad, Ashutosh Sabnis, Uday Pawar, Abhay Nene.   

Abstract

PURPOSE: As Indian spine surgeons, we have to choose between 'foreign implants' and 'Indian implants'. An Indian four pedicle screw rod construct costs 330 US dollars (one-third that of a similar foreign construct). About 60% of patients cannot afford expensive foreign implants. There is little written data evaluating how these Indian implants fare. The purpose of our study was to evaluate implant failure rate with Indian implants and compare it to foreign implants.
METHODS: We analysed results of 1,572 titanium pedicle screws used in 239 patients with a minimum 1-year follow-up. Patients were divided into Indian and foreign implant groups. Radiological failures were classified as (1) surgery and disease failure, (2) bone failure and (3) implant failure. The null hypothesis was that there is no difference between implant failure rate for Indian and foreign implants.
RESULTS: A total of 128 (53.56%) of patients could not afford foreign implants. We used 679 foreign and 893 Indian pedicle screws. In foreign implant group, there was a single incident of implant failure (0.15%). In Indian implant group, there were five such incidents (0.56%).
CONCLUSIONS: (1) Rate of failure for 'low cost' Indian implants is very low (approximately 1 implant complication for every 200 screws). (2) There is no statistically significant difference in failure rates for Indian implants and foreign implants (P-value = 0.2438). We recommend that Indian implants are a safe and viable option to make spine surgery cost effective in the Indian scenario.

Entities:  

Mesh:

Year:  2011        PMID: 21769442      PMCID: PMC3175863          DOI: 10.1007/s00586-011-1914-3

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  11 in total

Review 1.  The use of pedicle-screw internal fixation for the operative treatment of spinal disorders.

Authors:  R W Gaines
Journal:  J Bone Joint Surg Am       Date:  2000-10       Impact factor: 5.284

2.  The effect of bone quality on pedicle screw loading in axial instability. A synthetic model.

Authors:  R F McLain; T O McKinley; S A Yerby; T S Smith; N Sarigul-Klijn
Journal:  Spine (Phila Pa 1976)       Date:  1997-07-01       Impact factor: 3.468

Review 3.  Lumbar spinal stenosis.

Authors:  W H Kirkaldy-Willis; K W Paine; J Cauchoix; G McIvor
Journal:  Clin Orthop Relat Res       Date:  1974 Mar-Apr       Impact factor: 4.176

4.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members.

Authors:  S I Esses; B L Sachs; V Dreyzin
Journal:  Spine (Phila Pa 1976)       Date:  1993-11       Impact factor: 3.468

5.  An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine.

Authors:  K Hasegawa; H E Takahashi; S Uchiyama; T Hirano; T Hara; T Washio; T Sugiura; M Youkaichiya; M Ikeda
Journal:  Spine (Phila Pa 1976)       Date:  1997-05-01       Impact factor: 3.468

6.  Survivorship analysis of pedicle spinal instrumentation.

Authors:  P C McAfee; D J Weiland; J J Carlow
Journal:  Spine (Phila Pa 1976)       Date:  1991-08       Impact factor: 3.468

7.  Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique.

Authors:  Ming-Chau Chang; Chien-Lin Liu; Tain-Hsiung Chen
Journal:  Spine (Phila Pa 1976)       Date:  2008-05-01       Impact factor: 3.468

8.  Revision strategies for complications and failure of vertebroplasties.

Authors:  Shih-Chieh Yang; Wen-Jer Chen; Shang-Won Yu; Yuan-Kun Tu; Yu-Hsien Kao; Kao-Chi Chung
Journal:  Eur Spine J       Date:  2008-04-30       Impact factor: 3.134

9.  Effects of bone mineral density on pedicle screw fixation.

Authors:  T L Halvorson; L A Kelley; K A Thomas; T S Whitecloud; S D Cook
Journal:  Spine (Phila Pa 1976)       Date:  1994-11-01       Impact factor: 3.468

10.  Long-term functional outcome of pedicle screw instrumentation as a support for posterolateral spinal fusion: randomized clinical study with a 5-year follow-up.

Authors:  Finn Bjarke Christensen; Ebbe Stender Hansen; Malene Laursen; Karsten Thomsen; Cody E Bünger
Journal:  Spine (Phila Pa 1976)       Date:  2002-06-15       Impact factor: 3.468

View more
  1 in total

1.  Methylmethacrylate Inter-Facetal and Inter-Vertebral Body Spacers for Cranio-Vertebral Junction and Various Spine Surgeries: Technical Note.

Authors:  Deepak Kumar Jha; Mayank Garg; Suryanarayanan Bhaskar; Jaskaran Singh Gosal; Kartikeya Shukla; Vinay Kumar Chugh; Pushpinder Khera; Pradeep Kumar Bhatia
Journal:  Asian J Neurosurg       Date:  2021-09-14
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.