| Literature DB >> 34660389 |
Deepak Kumar Jha1, Mayank Garg1, Suryanarayanan Bhaskar1, Jaskaran Singh Gosal1, Kartikeya Shukla1, Vinay Kumar Chugh2, Pushpinder Khera3, Pradeep Kumar Bhatia4.
Abstract
STUDYEntities:
Keywords: Bone cement; cranio-vertebral junction; intervertebral spacer; methylmethacrylate; spacer
Year: 2021 PMID: 34660389 PMCID: PMC8477841 DOI: 10.4103/ajns.AJNS_443_20
Source DB: PubMed Journal: Asian J Neurosurg
Figure 1Shows plastic designs/models of spacers for craniovertebral junction (black arrow), Cervical Spine (red arrow) and Lumbar and Lumbo-sacral Spine (yellow arrow)
Figure 2Show Silicon (a) with embedded plastic designs/models of spacers (black arrow). Moulds prepared of Silicon (b) showing cavities in silicone mould (black arrow in b)
Figure 3Shows silicone mould (red arrows) filled up with bone cement (a). Bone cement spacers removed from the moulds (b) and after removal of spilled over bone cement (c) by instruments like nibbler
Figure 4Shows bone cement spacers (yellow arrow) inserted in bilateral C1-2 facet joints (a) and C3-4 disc space after Discectomy (b). Postoperative day 1 computed tomography scans, bone windows of craniovertebral junction, midline sagittal (c) and coronal (d) and cervical spine, midline sagittal pre-operative (e) and postoperative (f) images show spacers (yellow arrow). Preoperative (g), postoperative day 1 (h) and 3-months follow up (i) midline sagittal bone window computed tomography scan images show spacer (yellow arrow) with maintained distraction of L4-5 in an operated patient of L4-5 Spondylolisthesis
Figure 5Shows bone cement spacers with filled up pieces of harvested auto-graft bone in the central hole of the spacers (a), Operative photo of bone cement spacers (arrows) inserted between bilateral C1-2 lateral masses (Facets) for distraction along with Occiptal plate and C2 Laminar screws inserted (b), Postoperative day-1 noncontrast computed tomography scan, right (c) and left (d) para-sagital views showing C1-2 lateral mass spacers (arrows) with bone graft and midline sagital view (e) showing normal alignment of craniovertebral junction
Clinical characteristics, diagnosis, relevant signs/symptoms, surgeries done and dimensions of bone cement spacers used.
| Age (years) | Sex | Diagnosis | Clinical symptoms | Surgery | Spacer dimensions (L×B × H mm) |
|---|---|---|---|---|---|
| 22 | Female | BI | Quadriparesis | DCER | 12×10×7 |
| 27 | Male | BI | Quadriparesis | DCER | 12×10×7 |
| 14 | Female | BI | Quadriparesis with RI | DCER | 12×10×7 |
| 30 | Male | C3-4 PIVD | Quadriparesis | ACDF | 15×12×7 |
| 56 | Male | L4-5 listhesis | LBA | L4-5 PLIF | 18×12×9 |
| 34 | Male | C5-6 PIVD | Radicular pain with numbness | ACDF | 15×12×7 |
| 67 | Male | L4-5 listhesis | Radicular pain with numbness | L4-5 PLIF | 18×12×8 |
| 45 | Female | BI | Quadriparesis | DCER | 12×10×8 |
| 17 | Male | BI | Radicular pain with numbness | DCER | 12×10×8 |
| 14 | Male | BI | Quadriparesis with RI and LCN | DCER+TOO | 12×10×9 |
| 60 | Female | BI | Quadriparesis | DCER | 12×10×7 |
| 14 | Male | BI | Quadriparesis | DCER | 12×10×6 |
| 14 | Male | BI | Quadriparesis with RI and LCN | DCER | 12×10×7 |
| 12* | Male | D2 potts spine | Paraplegia with BB | D2 Left TPD with FF | 26×15×12 |
| 17 | Male | L5-S1 listhesis | LBA | L5-S1 Listhesis | 18×12×8 |
| 58 | Male | C3-4 PIVD | Quadriparesis | ACDF | 15×12×7 |
*Bone cement spacer was made manually. L - Length; B - Breadth; H - Height; BI - Basilar invagination; DCER - Occiput-C2 distraction, compression, extension and reduction by C1-2 facet joint spacers with fusion and fixation of occiput-C2 by autograft and titanium occipital plates and C2 laminar screws; PIVD - Prolapsed intervertebral disc; PLIF: Posterior lumbar inter-vertebral body fixation; TOO - Trans-oral odontoidectomy; RI - Respiratory involvement; BB - Bladder/bowel involvement; LCN - Lower cranial nerve palsy; TPD - Trans-pedicular decompression; FF - Fusion and fixation by autograft and titanium screws and rods; LBA - Low backache; ACDF - Anterior Cervical Discectomy with Fusion