Literature DB >> 7846594

Effects of bone mineral density on pedicle screw fixation.

T L Halvorson1, L A Kelley, K A Thomas, T S Whitecloud, S D Cook.   

Abstract

STUDY
DESIGN: In an attempt to evaluate the effects of bone mineral density on the quality of fixation of pedicle screws in the lumbar spine, the axial pullout force was determined and compared in normal and osteoporotic human lumbar spines.
OBJECTIVES: Four techniques of screw hole preparation were evaluated. Two pedicle screw/offset laminar hook constructs also were evaluated to determine whether the adjunct fixation of the laminar hooks would improve quality of fixation to a level sufficient to allow their use in the osteoporotic lumbar spine.
METHODS: Pedicle screws were inserted by one of the listed techniques into fresh frozen cadaveric human spines. The fixation strength then was evaluated by pullout on a uniaxial testing frame.
RESULTS: Bone mineral density was a strong influence on axial pullout force. In normal bone, the method of screw hole preparation did not significantly affect the quality of fixation. However, in the osteoporotic spine, either an untapped screw hole or the tapping of a screw hole with a 5.5 mm tap improved the pullout force a statistically significant amount (P < 0.003). Also, a pedicle screw with offset hooks at two adjacent levels improved the fixation significantly, increasing the pullout force to twice the expected value.
CONCLUSION: Pedicle screw pullout strength was highly correlated with bone mineral density. A 5.5 mm tap or preparation with a ganglion knife improved pullout strength. Use of pedicle screws in conjunction with laminar hooks at two levels improved pullout strength.

Entities:  

Mesh:

Year:  1994        PMID: 7846594     DOI: 10.1097/00007632-199411000-00008

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  112 in total

1.  [Cement distribution in vertebroplasty pedicle screws with different designs].

Authors:  K Kafchitsas; F Geiger; M Rauschmann; S Schmidt
Journal:  Orthopade       Date:  2010-07       Impact factor: 1.087

2.  [Pedicle screw augmentation from a biomechanical perspective].

Authors:  V Bullmann; U R Liljenqvist; R Rödl; T L Schulte
Journal:  Orthopade       Date:  2010-07       Impact factor: 1.087

3.  Assessment of the morpho-densitometric parameters of the lumbar pedicles in osteoporotic and control women undergoing routine abdominal MDCT examinations.

Authors:  Antonios E Papadakis; Apostolos H Karantanas; Giorgos Papadokostakis; John Damilakis
Journal:  J Bone Miner Metab       Date:  2010-10-26       Impact factor: 2.626

4.  Advanced Multi-Axis Spine Testing: Clinical Relevance and Research Recommendations.

Authors:  Timothy P Holsgrove; Nikhil R Nayak; William C Welch; Beth A Winkelstein
Journal:  Int J Spine Surg       Date:  2015-07-17

5.  Accuracy of DXA scanning of the thoracic spine: cadaveric studies comparing BMC, areal BMD and geometric estimates of volumetric BMD against ash weight and CT measures of bone volume.

Authors:  Meena M Sran; Karim M Khan; Kathy Keiver; Jason B Chew; Heather A McKay; Thomas R Oxland
Journal:  Eur Spine J       Date:  2004-12-23       Impact factor: 3.134

6.  Biomechanical evaluation of an expansive pedicle screw in calf vertebrae.

Authors:  Wei Lei; Zixiang Wu
Journal:  Eur Spine J       Date:  2005-04-30       Impact factor: 3.134

7.  A biomechanical analysis of the self-retaining pedicle hook device in posterior spinal fixation.

Authors:  Wilbert van Laar; Rinse J Meester; Theo H Smit; Barend J van Royen
Journal:  Eur Spine J       Date:  2007-01-03       Impact factor: 3.134

8.  Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies.

Authors:  Konrad Seller; Dieter Wahl; Alexander Wild; Rüdiger Krauspe; Erich Schneider; Berend Linke
Journal:  Eur Spine J       Date:  2007-02-02       Impact factor: 3.134

9.  One-screw fixation provides similar stability to that of two-screw fixation for type II dens fractures.

Authors:  Gang Feng; Robert Wendlandt; Sebastian Spuck; Arndt P Schulz
Journal:  Clin Orthop Relat Res       Date:  2012-05-15       Impact factor: 4.176

10.  Alignment of pedicle screws with pilot holes: can tapping improve screw trajectory in thoracic spines?

Authors:  Serkan Erkan; Brian Hsu; Chunhui Wu; Amir A Mehbod; John Perl; Ensor E Transfeldt
Journal:  Eur Spine J       Date:  2009-06-14       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.