INTRODUCTION: This study aimed to develop a simple and inexpensive ex vivo model to teach students the use of electronic apex locators in a preclinical setting.
METHODS: Using 27 extracted human teeth, the Raypex 5 (VDW, Munich, Germany) and Dentaport ZX (J. Morita Co, Kyoto, Japan) were tested in three different media (ie, alginate, sugar-free gelatin, and 0.9% sodium chloride solution). Working lengths determined by these models were compared with those obtained by digital radiography and direct visualization using a linear mixed modeling statistical approach.
RESULTS: Raypex 5 exhibited a higher percentage of measurements accurate to ± 0.5 mm and ± 1.0 mm of the control across all three media in all tooth types. In multirooted teeth, alginate showed the highest accuracy.
CONCLUSIONS: The most accurate EAL/embedding medium combination was Raypex 5/alginate to both ± 0.5 mm and ± 1.0 mm of the control. The model tested in this study was accurate, easy to assemble, and cost-effective, making it suitable for teaching purposes.
Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21763911     DOI: 10.1016/j.joen.2011.03.032

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  5 in total

1.  Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability.

Authors:  Franck Diemer; Emma Plews; Marie Georgelin-Gurgel; Lora Mishra; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2022-01-23       Impact factor: 3.623

2.  Effect of pre-flaring and file size on the accuracy of two electronic apex locators.

Authors:  Manoel Brito-Júnior; Carla Cristina Camilo; Gil Moreira-Júnior; Jesus Djalma Pecora; Manoel Damião Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

3.  Accuracy of electronic apex locators to detect root canal perforations with inserted metallic posts: an ex vivo study.

Authors:  Benjamín Briseño Marroquín; Claudia Cortazar Fernández; Irene Schmidtmann; Brita Willershausen; Fernando Goldberg
Journal:  Head Face Med       Date:  2014-12-23       Impact factor: 2.151

4.  Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study.

Authors:  Thomas Gerhard Wolf; Anna Krauß-Mironjuk; Richard Johannes Wierichs; Benjamín Briseño-Marroquín
Journal:  Sci Rep       Date:  2021-02-08       Impact factor: 4.379

5.  Effect of Orthodontic Brackets on the Accuracy of Apex Locators: A Pilot Study.

Authors:  Özgür Genç Şen; Özgür İlke Ulusoy; Yelda Nayır Paltun; Çağrı Ulusoy
Journal:  Biomed Res Int       Date:  2021-04-24       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.