Literature DB >> 21755331

Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis.

Joerg Friesenbichler1, Werner Maurer-Ertl, Patrick Sadoghi, Thomas Lovse, Reinhard Windhager, Andreas Leithner.   

Abstract

PURPOSE: The effects of systemic metal ion exposure in patients with implants made of common prosthetic alloys continue to be a matter of concern. The aim of the study was to determine the measurement values of cobalt (Co), chromium (Cr) and molybdenum (Mo) in serum following rotating-hinge knee arthroplasty.
METHODS: Blood was taken from 25 patients [mean follow-up 35 (range nine to 67) months] treated with megaprostheses (n=17) or standard rotating-hinge devices (n=8) and analysed using electrothermal graphite furnace atomic absorption spectrometry (ET-ASS).
RESULTS: Determining the concentrations of metal ions following rotating-hinge knee arthroplasty revealed increments for Co and Cr but not Mo. Metal ion release was significantly higher in patients with megaprostheses compared to a standard rotating-hinge knee device (Co p=0,024; Cr p=0.025).
CONCLUSION: The authors believe there might be an additional metal ion release from the surface of the prosthesis and not only from the articulating surfaces because, in cases of rotating-hinge knee prosthesis, there is a metal-on-polyethylene articulation and not a direct metal-on-metal junction. Nevertheless, long-term studies are required to determine adverse effects of Co, Cr and Mo following total hip replacement and total knee arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21755331      PMCID: PMC3291763          DOI: 10.1007/s00264-011-1317-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  24 in total

1.  How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?

Authors:  Diane L Back; D A Young; A J Shimmin
Journal:  Clin Orthop Relat Res       Date:  2005-09       Impact factor: 4.176

2.  Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty: four-year results of a prospective longitudinal study.

Authors:  J Daniel; H Ziaee; C Pradhan; P B Pynsent; D J W McMinn
Journal:  J Bone Joint Surg Br       Date:  2007-02

3.  The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip.

Authors:  D J Langton; S S Jameson; T J Joyce; J Webb; A V F Nargol
Journal:  J Bone Joint Surg Br       Date:  2008-09

4.  Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.

Authors:  Wolf-Christoph Witzleb; Joerg Ziegler; Frank Krummenauer; Volker Neumeister; Klaus-Peter Guenther
Journal:  Acta Orthop       Date:  2006-10       Impact factor: 3.717

5.  Long-term follow-up of metal-on-metal total hip replacement.

Authors:  Alexander Grübl; Martina Marker; Wolfram Brodner; Alexander Giurea; Georg Heinze; Vanee Meisinger; Harald Zehetgruber; Rainer Kotz
Journal:  J Orthop Res       Date:  2007-07       Impact factor: 3.494

6.  Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study.

Authors:  Hans-Georg Willert; Gottfried H Buchhorn; Afshin Fayyazi; Renata Flury; Markus Windler; Georg Köster; Christoph H Lohmann
Journal:  J Bone Joint Surg Am       Date:  2005-01       Impact factor: 5.284

7.  Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty.

Authors:  Dariusz Ladon; Ann Doherty; Roger Newson; Justine Turner; Manjit Bhamra; C Patrick Case
Journal:  J Arthroplasty       Date:  2004-12       Impact factor: 4.757

8.  Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.

Authors:  John Antoniou; David J Zukor; Fackson Mwale; William Minarik; Alain Petit; Olga L Huk
Journal:  J Bone Joint Surg Am       Date:  2008-08       Impact factor: 5.284

9.  Metal ion levels after metal-on-metal Ring total hip replacement: a 30-year follow-up study.

Authors:  P Sauvé; J Mountney; T Khan; J De Beer; B Higgins; M Grover
Journal:  J Bone Joint Surg Br       Date:  2007-05

10.  The association between metal ions from hip resurfacing and reduced T-cell counts.

Authors:  A J Hart; T Hester; K Sinclair; J J Powell; A E Goodship; L Pele; N L Fersht; J Skinner
Journal:  J Bone Joint Surg Br       Date:  2006-04
View more
  7 in total

1.  Metallic ion release after knee prosthesis implantation: a prospective study.

Authors:  Adrien Lons; Sophie Putman; Gilles Pasquier; Henri Migaud; Elodie Drumez; Julien Girard
Journal:  Int Orthop       Date:  2017-06-14       Impact factor: 3.075

2.  Are Serum Metal Ion Levels a Concern at Mid-term Followup of Revision Knee Arthroplasty With a Metal-on-metal Hinge Design?

Authors:  Antonio Klasan; Esko Meine; Susanne Fuchs-Winkelmann; Turgay Efe; Friedrich Boettner; Thomas Jan Heyse
Journal:  Clin Orthop Relat Res       Date:  2019-09       Impact factor: 4.176

3.  Metal hypersensitivity and metal ion levels in patients with coated or uncoated total knee arthroplasty: a randomised controlled study.

Authors:  Jörg Lützner; Albrecht Hartmann; Gerd Dinnebier; Petra Spornraft-Ragaller; Christine Hamann; Stephan Kirschner
Journal:  Int Orthop       Date:  2013-07-17       Impact factor: 3.075

4.  [In vitro analysis of the impact of metal ions on human lymphocyte cultures].

Authors:  S Hagmann; J Kirsch; J P Kretzer; B Moradi
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

5.  Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: a randomized controlled study.

Authors:  Anne Postler; Franziska Beyer; Cornelia Lützner; Eric Tille; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-03       Impact factor: 4.342

6.  Serum metal ion concentrations in paediatric patients following total knee arthroplasty using megaprostheses.

Authors:  Jörg Friesenbichler; Patrick Sadoghi; Werner Maurer-Ertl; Joanna Szkandera; Mathias Glehr; Kathrin Ogris; Matthias Wolf; Christian Weger; Andreas Leithner
Journal:  Biomed Res Int       Date:  2014-09-08       Impact factor: 3.411

7.  [The use of knee prostheses with a hypoallergenic coating is safe in the medium term : A randomized controlled study].

Authors:  Anne Postler; Franziska Beyer; Cornelia Lützner; Eric Tille; Jörg Lützner
Journal:  Orthopadie (Heidelb)       Date:  2021-11-03
  7 in total