Literature DB >> 17068698

Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.

Wolf-Christoph Witzleb1, Joerg Ziegler, Frank Krummenauer, Volker Neumeister, Klaus-Peter Guenther.   

Abstract

BACKGROUND: All metal implants--and metal-on-metal bearings in particular--corrode and cause a release of metal ions. Because cobalt and chromium have been shown to be carcinogenic and mutagenic in human and animal models, systemic toxicity and cancer risk are considered to be possible disadvantages of the metal-on-metal articulation. This study was designed to investigate the serum concentration profiles of chromium, cobalt and molybdenum after implantation of a Birmingham hip resurfacing arthroplasty (BHR) and a cementless total hip replacement with a 28-mm Metasul articulation (MTHR), over the first 2 years after implantation.
METHODS: We analyzed profiles of metal ion serum levels in 111 patients implanted with a BHR, in 74 patients implanted with an MTHR, and in 130 implant-free probands control subjects using atomic absorption spectrophotometry.
RESULTS: Chromium and cobalt concentrations (in microg/L) of all BHR and MTHR patients differed significantly from those of control subjects (chromium: < 0.25; cobalt: 0.25). The median chromium and cobalt concentrations in BHR patients had increased to 5.1 and 4.3 microg/L 2 years after surgery. Concentrations in BHR patient exceeded those in the unilateral MTHR patients. Molybdenum serum concentrations hardly changed over time in either group and were not significantly different from the concentrations seen in the control subjects.
INTERPRETATION: During the first 2 years after surgery, the Birmingham hip resurfacing arthroplasty leads to a significantly greater increase in serum chromium and cobalt levels than the 28-mm metal-on-metal MTHR. Observation of patients over a longer period will be necessary in order to evaluate any chronic adverse effects to the system due to elevated chromium and cobalt serum concentrations.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17068698     DOI: 10.1080/17453670610012863

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  28 in total

Review 1.  [Results for endoprosthetic care in patients younger than 50 years].

Authors:  J Ziegler; M Amlang; M Bottesi; S Kirschner; W-C Witzleb; K-P Günther
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

2.  Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis.

Authors:  Joerg Friesenbichler; Werner Maurer-Ertl; Patrick Sadoghi; Thomas Lovse; Reinhard Windhager; Andreas Leithner
Journal:  Int Orthop       Date:  2011-07-14       Impact factor: 3.075

3.  Serum ion level after metal-on-metal THA in patients with renal failure.

Authors:  Chang Ich Hur; Taek Rim Yoon; Sang Gwon Cho; Eun Kyoo Song; Jong Keun Seon
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

Review 4.  [Revision surgery of hip resurfacing].

Authors:  K-P Günther; W-C Witzleb; M Stiehler; S Kirschner
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

5.  Acetabular component thickness does not affect mid-term clinical results in hip resurfacing.

Authors:  Mariam Al-Hamad; Michel J Le Duff; Karren M Takamura; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2014-01-22       Impact factor: 4.176

6.  Biodegradable nanofiber-based piezoelectric transducer.

Authors:  Eli J Curry; Thinh T Le; Ritopa Das; Kai Ke; Elise M Santorella; Debayon Paul; Meysam T Chorsi; Khanh T M Tran; Jeffrey Baroody; Emily R Borges; Brian Ko; Asiyeh Golabchi; Xiaonan Xin; David Rowe; Lixia Yue; Jianlin Feng; M Daniela Morales-Acosta; Qian Wu; I-Ping Chen; X Tracy Cui; Joel Pachter; Thanh D Nguyen
Journal:  Proc Natl Acad Sci U S A       Date:  2019-12-23       Impact factor: 11.205

7.  Do ion levels in hip resurfacing differ from metal-on-metal THA at midterm?

Authors:  A Moroni; L Savarino; M Hoque; M Cadossi; N Baldini
Journal:  Clin Orthop Relat Res       Date:  2010-06-11       Impact factor: 4.176

8.  [Different symptoms in patients with prostheses with metal-metal bearings].

Authors:  M Thomsen; J P Kretzer; V Krenn; P Thomas
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

9.  Delayed sciatic nerve palsy following resurfacing hip arthroplasty caused by metal debris.

Authors:  Babar Kayani; Jeeshan Rahman; Sammy A Hanna; Stephen R Cannon; William J Aston; Jonathan Miles
Journal:  BMJ Case Rep       Date:  2012-11-14

Review 10.  [Biomechanical aspects of the implant fixation and kinematics of hip resurfacing systems].

Authors:  R Bader; D Klüss; L Gerdesmeyer; E Steinhauser
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.