Literature DB >> 17405158

Long-term follow-up of metal-on-metal total hip replacement.

Alexander Grübl1, Martina Marker, Wolfram Brodner, Alexander Giurea, Georg Heinze, Vanee Meisinger, Harald Zehetgruber, Rainer Kotz.   

Abstract

Metal-on-metal articulations were reintroduced to reduce polyethylene particle-induced osteolysis. Elevated serum metal levels have been detected at short- and intermediate-term follow-up. There is little knowledge about long-term effects of increased ionic metal generation. Our study was undertaken to provide information about long-term survival, clinical outcome, radiographic appearance, and serum metal concentrations after a minimum 10 years follow-up with a metal-on-metal hip prosthesis: 105 cementless primary total hip prostheses with metal-on-metal articulating surfaces were implanted in 98 patients with a mean age of 56 years. Clinical data, radiographs, and blood samples were obtained at a follow-up visit 10 years after implantation. Serum cobalt and chromium levels were determined with use of atomic absorption spectrometry. General laboratory analyses included a full blood count and kidney function parameters. The Harris score was 92 points and the UCLA score 6 points after 10 years. Small osteolytic lesions and radiolucent lines were found in Gruen's zones 1, 7, 8, and 14. The probability of survival was 98.6%. The median serum cobalt concentration of the 22 patients with their hip replacement as the only source of cobalt was 0.75 microg/L (range, 0.3-50.1 microg/L). No patient was diagnosed with renal insufficiency during the study period. Five patients were diagnosed with a malignancy between surgery and the follow-up. We do not have evidence of an increased rate of primary malignancies nor could we detect renal failure in our study group. Serum metal levels did not differ from short- and intermediate term follow-up values. Copyright (c) 2007 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17405158     DOI: 10.1002/jor.20381

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  41 in total

1.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Perioperative management of patients with connective tissue disease.

Authors:  Susan M Goodman; Mark P Figgie; C Ronald Mackenzie
Journal:  HSS J       Date:  2010-08-17

3.  Cup loosening after cemented Metasul® total hip replacement: a retrieval analysis.

Authors:  Christophe Nich; Moussa Hamadouche
Journal:  Int Orthop       Date:  2010-06-11       Impact factor: 3.075

Review 4.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

5.  Do "premium" joint implants add value?: analysis of high cost joint implants in a community registry.

Authors:  Terence J Gioe; Amit Sharma; Penny Tatman; Susan Mehle
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

6.  [MUW researcher of the month].

Authors:  Richard Lass
Journal:  Wien Klin Wochenschr       Date:  2015-11       Impact factor: 1.704

7.  CORR Insights(®): oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  Alexander Jaime Grübl
Journal:  Clin Orthop Relat Res       Date:  2015-09-10       Impact factor: 4.176

8.  Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis.

Authors:  Joerg Friesenbichler; Werner Maurer-Ertl; Patrick Sadoghi; Thomas Lovse; Reinhard Windhager; Andreas Leithner
Journal:  Int Orthop       Date:  2011-07-14       Impact factor: 3.075

9.  Changes in serum chromium levels over 12 years after Metasul metal-on-metal total hip arthroplasty.

Authors:  Katsuhiko Maezawa; Masahiko Nozawa; Takahito Yuasa; Munehiko Sugimoto; Kazuo Kaneko
Journal:  J Orthop       Date:  2018-02-28

10.  Adverse Reactions to Metal on Metal Are Not Exclusive to Large Heads in Total Hip Arthroplasty.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams; Keri L Satterwhite
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.