Literature DB >> 21744246

Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition.

Jelena R Ghadri1, Silke M Küest, Robert Goetti, Michael Fiechter, Aju P Pazhenkottil, Rene N Nkoulou, Felix P Kuhn, Carsten Pietsch, Patrick von Schulthess, Oliver Gaemperli, Christian Templin, Philipp A Kaufmann.   

Abstract

Currently 64-multislice computed tomography (MSCT) scanners are the most widely used devices allowing low radiation dose coronary CT angiography (CCTA) with prospective ECG triggering. Latest 128-slice dual-source CT (DSCT) scanners offer prospective high-pitch spiral acquisition covering the heart during one single beat. We compared radiation dose and image quality from prospective 64-MSCT versus high-pitch spiral 128-slice DSCT scanning, as such data is lacking. CCTA of 50 consecutive patients undergoing 128-DSCT (2 × 64 × 0.6 mm collimation, 0.28 s rotation time, 3.4 pitch, 100-120 kV tube voltage and 320 mAs tube current-time product) were compared to CCTA of 50 heart rate (HR) and BMI matched patients undergoing 64-MSCT (64 × 0.625 mm collimation, 0.35 s rotation time, 100-120 kV tube voltage and 400-650 mA tube current). Image quality was rated on a 4-point scale by two independent cardiac imaging physicians (1 = excellent to 4 = non-diagnostic). Of 710 coronary segments assessed on 128-DSCT, 216 (30.4%) achieved an image quality score 1 excellent, 400 (56.3%) score 2, 76 (10.7%) score 3 and 18 (2.6%) score 4 (non-diagnostic). Of 737 coronary segments evaluated on 64-MSCT 271 (36.8%) had an image quality score of 1, 327 (44.4%) 2, 110 (14.9%) score 3, and 29 (3.9%) segments score 4. Average image quality score for both scanners was similar (P = 0.641). The mean heart rate during scanning was 58.7 ± 5.6 bpm on 128-DSCT and 59.0 ± 5.6 bpm on 64-MSCT, respectively. Mean effective radiation dose was 1.0 ± 0.2 mSv for 128-DSCT and 1.7 ± 0.6 mSv for 64-MSCT (P < 0.001). 128-DSCT with high-pitch spiral mode allows CCTA acquisition with reduced radiation dose at maintained image quality compared to 64-MSCT.

Entities:  

Mesh:

Year:  2011        PMID: 21744246     DOI: 10.1007/s10554-011-9921-3

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  25 in total

1.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

2.  Low-dose CT coronary angiography using prospective ECG-triggering: impact of mean heart rate and heart rate variability on image quality.

Authors:  Bernhard A Herzog; Lars Husmann; Nina Burkhard; Ines Valenta; Oliver Gaemperli; Fuminari Tatsugami; Christophe A Wyss; Uif Landmesser; Philipp A Kaufmann
Journal:  Acad Radiol       Date:  2009-01       Impact factor: 3.173

3.  Low-dose computed tomography coronary angiography with prospective triggering: a promise for the future.

Authors:  Philipp A Kaufmann
Journal:  J Am Coll Cardiol       Date:  2008-10-28       Impact factor: 24.094

4.  First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography.

Authors:  B A Herzog; C A Wyss; L Husmann; O Gaemperli; I Valenta; V Treyer; U Landmesser; P A Kaufmann
Journal:  Heart       Date:  2009-07-05       Impact factor: 5.994

5.  Low-dose coronary CT angiography with prospective ECG triggering: validation of a contrast material protocol adapted to body mass index.

Authors:  Lars Husmann; Bernhard A Herzog; Nina Burkhard; Ines Valenta; Irene A Burger; Oliver Gaemperli; Philipp A Kaufmann
Journal:  AJR Am J Roentgenol       Date:  2009-09       Impact factor: 3.959

Review 6.  Radiation dose to patients from cardiac diagnostic imaging.

Authors:  Andrew J Einstein; Kevin W Moser; Randall C Thompson; Manuel D Cerqueira; Milena J Henzlova
Journal:  Circulation       Date:  2007-09-11       Impact factor: 29.690

7.  High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates.

Authors:  Robert Goetti; Gudrun Feuchtner; Paul Stolzmann; Lotus Desbiolles; Michael Alexander Fischer; Christoph Karlo; Stephan Baumueller; Hans Scheffel; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-06-29       Impact factor: 5.315

8.  Low dose high-pitch spiral acquisition 128-slice dual-source computed tomography for the evaluation of coronary artery bypass graft patency.

Authors:  Robert Goetti; Sebastian Leschka; Stephan Baumüller; André Plass; Monika Wieser; Lotus Desbiolles; Paul Stolzmann; Volkmar Falk; Borut Marincek; Hatem Alkadhi; Gudrun Feuchtner
Journal:  Invest Radiol       Date:  2010-06       Impact factor: 6.016

9.  Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering.

Authors:  Lars Husmann; Bernhard A Herzog; Nina Burkhard; Fuminari Tatsugami; Ines Valenta; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

10.  Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience.

Authors:  Sebastian Leschka; Paul Stolzmann; Lotus Desbiolles; Stephan Baumueller; Robert Goetti; Thomas Schertler; Hans Scheffel; Andre Plass; Volkmar Falk; Gudrun Feuchtner; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

View more
  23 in total

Review 1.  Important advances in technology and unique applications to cardiovascular computed tomography.

Authors:  Kongkiat Chaikriangkrai; Su Yeon Choi; Faisal Nabi; Su Min Chang
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

2.  Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm.

Authors:  Takeshi Nakaura; Masafumi Kidoh; Naritsugu Sakaino; Daisuke Utsunomiya; Seitaro Oda; Tetsuya Kawahara; Kazunori Harada; Yasuyuki Yamashita
Journal:  Int J Cardiovasc Imaging       Date:  2012-11-17       Impact factor: 2.357

3.  CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis.

Authors:  Tobias A Fuchs; Michael Fiechter; Cathérine Gebhard; Julia Stehli; Jelena R Ghadri; Egle Kazakauskaite; Bernhard A Herzog; Lars Husmann; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2012-10-02       Impact factor: 2.357

4.  Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine.

Authors:  Jean-François Paul; Aude Amato; Adela Rohnean
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-24       Impact factor: 2.357

5.  First in vivo head-to-head comparison of high-definition versus standard-definition stent imaging with 64-slice computed tomography.

Authors:  Tobias A Fuchs; Julia Stehli; Michael Fiechter; Svetlana Dougoud; Bert-Ram Sah; Cathérine Gebhard; Sacha Bull; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-01       Impact factor: 2.357

6.  Coronary artery calcium quantification from contrast enhanced CT using gemstone spectral imaging and material decomposition.

Authors:  Tobias A Fuchs; Julia Stehli; Svetlana Dougoud; Bert-Ram Sah; Sacha Bull; Olivier F Clerc; Mathias Possner; Ronny R Buechel; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-04       Impact factor: 2.357

7.  Image Quality of 256-Slice Computed Tomography for Coronary Angiography.

Authors:  Shu-Ping Chao; Jyh-Gang Leu; Wai-Yip Law; Chu-Jen Kuo; Kou-Gi Shyu
Journal:  Acta Cardiol Sin       Date:  2013-09       Impact factor: 2.672

8.  Rationale and design of the worldwide prospective multicenter registry on radiation dose estimates of cardiac CT angiography in daily practice in 2017 (PROTECTION VI).

Authors:  Thomas J Stocker; Simon Deseive; Marcus Chen; Jonathon Leipsic; Martin Hadamitzky; Ronen Rubinshtein; Erik L Grove; Xiang-Ming Fang; John Lesser; Pál Maurovich-Horvat; Hugo Marques; Daniele Andreini; Ramzi Tabbalat; Joon-Won Kang; Joachim Eckert; Patricia Dickson; Signe H Forsdahl; Jess Lambrechtsen; Roberto C Cury; Jörg Hausleiter
Journal:  J Cardiovasc Comput Tomogr       Date:  2017-12-05

9.  Image quality of low-dose CCTA in obese patients: impact of high-definition computed tomography and adaptive statistical iterative reconstruction.

Authors:  Cathérine Gebhard; Tobias A Fuchs; Michael Fiechter; Julia Stehli; Barbara E Stähli; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-28       Impact factor: 2.357

10.  Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation.

Authors:  Daniele Andreini; Gianluca Pontone; Saima Mushtaq; Maria Elisabetta Mancini; Edoardo Conte; Marco Guglielmo; Valentina Volpato; Andrea Annoni; Andrea Baggiano; Alberto Formenti; Valentina Ditali; Marco Perchinunno; Cesare Fiorentini; Antonio L Bartorelli; Mauro Pepi
Journal:  Eur Radiol       Date:  2017-11-21       Impact factor: 5.315

View more