Literature DB >> 29164383

Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation.

Daniele Andreini1,2, Gianluca Pontone3, Saima Mushtaq3, Maria Elisabetta Mancini3, Edoardo Conte3, Marco Guglielmo3, Valentina Volpato3, Andrea Annoni3, Andrea Baggiano3, Alberto Formenti3, Valentina Ditali3, Marco Perchinunno4, Cesare Fiorentini3,5, Antonio L Bartorelli3,6, Mauro Pepi3.   

Abstract

OBJECTIVES: To evaluate image quality, coronary evaluability and radiation exposure of coronary CT angiography (CCTA) performed with whole-heart coverage cardiac-CT in patients with atrial fibrillation (AF).
MATERIALS AND METHODS: We prospectively enrolled 164 patients with AF who underwent a clinically indicated CCTA with a 16-cm z-axis coverage scanner. In all patients CCTA was performed using prospective ECG-triggering with targeted RR interval. We evaluated image quality, coronary evaluability and effective dose (ED). Patients were divided in two subgroups based on heart rate (HR) during imaging. Group 1: 64 patients with low HR (<75 bpm), group 2: 100 patients with high HR (≥75 bpm). Written informed consent was obtained from all patients and the institutional ethics committee approved the study protocol.
RESULTS: In a segment-based analysis, coronary evaluability was 98.4 % (2,577/2,620 segments) in the whole population, without significant differences between groups (1,013/1,024 (98.9 %) and 1,565/1,596 (98.1 %), for groups 1 and 2, respectively, p=0.15). Mean ED was similar in both groups (3.8±1.9 mSv and 3.9±2.1 mSv in groups 1 and 2, respectively, p=0.75)
CONCLUSIONS: The whole-heart-coverage scanner could evaluate coronary arteries with high image quality and without increase in radiation exposure in AF patients, even in the high HR group. KEY POINTS: • Last-generation CT scanner improves coronary artery assessment in AF patients. • The new CT scanner enables low radiation exposure in AF patients. • Diagnostic ICA maybe avoided in AF patients with suspected CAD. • Whole-heart coverage CT scanner enables low radiation exposure in AF patients.

Entities:  

Keywords:  Atrial fibrillation; Coronary CT angiography; Coronary evaluability; Image quality; Radiation dose

Mesh:

Year:  2017        PMID: 29164383     DOI: 10.1007/s00330-017-5131-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3(rd) generation dual-source CT.

Authors:  Stefanie Mangold; Julian L Wichmann; U Joseph Schoepf; Zachary B Poole; Christian Canstein; Akos Varga-Szemes; Damiano Caruso; Fabian Bamberg; Konstantin Nikolaou; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2016-02-04       Impact factor: 5.315

Review 2.  Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology.

Authors:  Stephen Schroeder; Stephan Achenbach; Frank Bengel; Christof Burgstahler; Filippo Cademartiri; Pim de Feyter; Richard George; Philipp Kaufmann; Andreas F Kopp; Juhani Knuuti; Dieter Ropers; Joanne Schuijf; Laurens F Tops; Jeroen J Bax
Journal:  Eur Heart J       Date:  2007-12-15       Impact factor: 29.983

3.  2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology.

Authors:  Gilles Montalescot; Udo Sechtem; Stephan Achenbach; Felicita Andreotti; Chris Arden; Andrzej Budaj; Raffaele Bugiardini; Filippo Crea; Thomas Cuisset; Carlo Di Mario; J Rafael Ferreira; Bernard J Gersh; Anselm K Gitt; Jean-Sebastien Hulot; Nikolaus Marx; Lionel H Opie; Matthias Pfisterer; Eva Prescott; Frank Ruschitzka; Manel Sabaté; Roxy Senior; David Paul Taggart; Ernst E van der Wall; Christiaan J M Vrints; Jose Luis Zamorano; Stephan Achenbach; Helmut Baumgartner; Jeroen J Bax; Héctor Bueno; Veronica Dean; Christi Deaton; Cetin Erol; Robert Fagard; Roberto Ferrari; David Hasdai; Arno W Hoes; Paulus Kirchhof; Juhani Knuuti; Philippe Kolh; Patrizio Lancellotti; Ales Linhart; Petros Nihoyannopoulos; Massimo F Piepoli; Piotr Ponikowski; Per Anton Sirnes; Juan Luis Tamargo; Michal Tendera; Adam Torbicki; William Wijns; Stephan Windecker; Juhani Knuuti; Marco Valgimigli; Héctor Bueno; Marc J Claeys; Norbert Donner-Banzhoff; Cetin Erol; Herbert Frank; Christian Funck-Brentano; Oliver Gaemperli; José R Gonzalez-Juanatey; Michalis Hamilos; David Hasdai; Steen Husted; Stefan K James; Kari Kervinen; Philippe Kolh; Steen Dalby Kristensen; Patrizio Lancellotti; Aldo Pietro Maggioni; Massimo F Piepoli; Axel R Pries; Francesco Romeo; Lars Rydén; Maarten L Simoons; Per Anton Sirnes; Ph Gabriel Steg; Adam Timmis; William Wijns; Stephan Windecker; Aylin Yildirir; Jose Luis Zamorano
Journal:  Eur Heart J       Date:  2013-08-30       Impact factor: 29.983

4.  Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.

Authors:  Rihyeon Kim; Eun-Ah Park; Whal Lee; Jin Wook Chung
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

5.  Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: a comparison between patients with chronic atrial fibrillation and subjects in normal sinus rhythm by propensity analysis.

Authors:  Ernesto Di Cesare; Antonio Gennarelli; Alessandra Di Sibio; Valentina Felli; Alessandra Splendiani; Giovanni Luca Gravina; Carlo Masciocchi
Journal:  Eur J Radiol       Date:  2015-01-02       Impact factor: 3.528

6.  64-MDCT coronary angiography of patients with atrial fibrillation: influence of heart rate on image quality and efficacy in evaluation of coronary artery disease.

Authors:  Lin Yang; Zhaoqi Zhang; Zhanming Fan; Chao Xu; Lei Zhao; Wei Yu; Zixu Yan
Journal:  AJR Am J Roentgenol       Date:  2009-09       Impact factor: 3.959

7.  Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT.

Authors:  Hiroto Yunaga; Yasutoshi Ohta; Yasuhiro Kaetsu; Shinichiro Kitao; Tomomi Watanabe; Yoshiyuki Furuse; Kazuhiro Yamamoto; Toshihide Ogawa
Journal:  Eur Radiol       Date:  2016-12-13       Impact factor: 5.315

8.  Noninvasive coronary angiography using dual-source computed tomography in patients with atrial fibrillation.

Authors:  Carsten Rist; Thorsten R Johnson; Jens Müller-Starck; Elisabeth Arnoldi; Tobias Saam; Alexander Becker; Alexander W Leber; Bernd J Wintersperger; Christoph R Becker; Maximilian F Reiser; Konstantin Nikolaou
Journal:  Invest Radiol       Date:  2009-03       Impact factor: 6.016

9.  Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMerge Italian Registry.

Authors:  Emanuele Bertaglia; Paolo Della Bella; Claudio Tondo; Alessandro Proclemer; Nicola Bottoni; Roberto De Ponti; Maurizio Landolina; Maria Grazia Bongiorni; Leonardo Corò; Giuseppe Stabile; Antonio Dello Russo; Roberto Verlato; Massimo Mantica; Franco Zoppo
Journal:  Europace       Date:  2009-06-18       Impact factor: 5.214

10.  Diagnostic value of 64-slice dual-source CT coronary angiography in patients with atrial fibrillation: comparison with invasive coronary angiography.

Authors:  Jian-Jun Zhang; Tie Liu; Yue Feng; Wei-Feng Wu; Cai-Yun Mou; Li-Hao Zhai
Journal:  Korean J Radiol       Date:  2011-07-22       Impact factor: 3.500

View more
  9 in total

1.  Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol.

Authors:  Yuhuan Chen; Zhentang Liu; Michelle Li; Yong Yu; Yongjun Jia; Guangming Ma; Zhijun Hu; DongHong Wei; Dou Li; Taiping He
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

2.  Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction.

Authors:  Yuhuan Chen; Qi Wang; Jianying Li; Yongjun Jia; Qi Yang; Taiping He
Journal:  Eur Radiol       Date:  2018-05-22       Impact factor: 5.315

Review 3.  SYNTAX II and SYNTAX III trials: what is the take home message for surgeons?

Authors:  Rodrigo Modolo; Carlos Collet; Yoshinobu Onuma; Patrick W Serruys
Journal:  Ann Cardiothorac Surg       Date:  2018-07

4.  Image quality and diagnostic accuracy of coronary CT angiography derived from low-dose dynamic CT myocardial perfusion: a feasibility study with comparison to invasive coronary angiography.

Authors:  Xu Dai; Mengmeng Yu; Jingwei Pan; Zhigang Lu; Chengxing Shen; Yining Wang; Bin Lu; Jiayin Zhang
Journal:  Eur Radiol       Date:  2018-11-09       Impact factor: 5.315

5.  Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate.

Authors:  Junfu Liang; Ying Sun; Ziqing Ye; Yanchun Sun; Lei Xu; Zhen Zhou; Brian Thomsen; Jianying Li; Zhonghua Sun; Zhanming Fan
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

6.  Potential increase in radiation-induced DNA double-strand breaks with higher doses of iodine contrast during coronary CT angiography.

Authors:  Toon Van Cauteren; Kaoru Tanaka; Dries Belsack; Gert Van Gompel; Veerle Kersemans; Kristin Jochmans; Steven Droogmans; Johan de Mey; Nico Buls
Journal:  Med Phys       Date:  2021-10-13       Impact factor: 4.506

7.  High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast doses.

Authors:  Wanjiang Li; Kaiyue Diao; Yuting Wen; Tao Shuai; Yongchun You; Jin Zhao; Kai Liao; Chunyan Lu; Jianqun Yu; Yong He; Zhenlin Li
Journal:  Eur Radiol       Date:  2022-01-21       Impact factor: 5.315

8.  Coronary computed tomography angiography for heart team decision-making in multivessel coronary artery disease.

Authors:  Carlos Collet; Yoshinobu Onuma; Daniele Andreini; Jeroen Sonck; Giulio Pompilio; Saima Mushtaq; Mark La Meir; Yosuke Miyazaki; Johan de Mey; Oliver Gaemperli; Ahmed Ouda; Juan Pablo Maureira; Damien Mandry; Edoardo Camenzind; Laurent Macron; Torsten Doenst; Ulf Teichgräber; Holger Sigusch; Taku Asano; Yuki Katagiri; Marie-Angele Morel; Wietze Lindeboom; Gianluca Pontone; Thomas F Lüscher; Antonio L Bartorelli; Patrick W Serruys
Journal:  Eur Heart J       Date:  2018-11-01       Impact factor: 29.983

9.  Radiation dose and image quality of CT coronary angiography in patients with high heart rate or irregular heart rhythm using a 16-cm wide detector CT scanner.

Authors:  Marian Ondrejkovic; Dusan Salat; Daniel Cambal; Andrej Klepanec
Journal:  Medicine (Baltimore)       Date:  2022-09-16       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.