Literature DB >> 24993390

Coronary artery calcium quantification from contrast enhanced CT using gemstone spectral imaging and material decomposition.

Tobias A Fuchs1, Julia Stehli, Svetlana Dougoud, Bert-Ram Sah, Sacha Bull, Olivier F Clerc, Mathias Possner, Ronny R Buechel, Oliver Gaemperli, Philipp A Kaufmann.   

Abstract

To explore the feasibility of coronary artery calcium (CAC) measurement from low-dose contrast enhanced coronary CT angiography (CCTA) as this may obviate the need for an unenhanced CT scan. 52 patients underwent unenhanced cardiac CT and prospectively ECG triggered contrast enhanced CCTA (Discovery HD 750, GE Healthcare, Milwaukee, WI, USA). The latter was acquired in single-source dual-energy mode [gemstone spectral imaging (GSI)]. Virtual unenhanced images were generated from GSI CCTA by monochromatic image reconstruction of 70 keV allowing selective iodine material suppression. CAC scores from virtual unenhanced CT were compared to standard unenhanced CT including a linear regression model. After iodine subtraction from the contrast enhanced CCTA the attenuation in the ascending aorta decreased significantly from 359 ± 61 to 54 ± 8 HU (P < 0.001), the latter comparing well to the value of 64 ± 55 HU found in the standard unenhanced CT (P = ns) confirming successful iodine subtraction. After introducing linear regression formula the mean values for Agatston, Volume and Mass scores of virtual unenhanced CT were 187 ± 321, 72 ± 114 mm(3), and 27 ± 46 mg/cm(3), comparing well to the values from standard unenhanced CT (187 ± 309, 72 ± 110 mm(3), and 27 ± 45 mg/cm(3)) yielding an excellent correlation (r = 0.96, r = 0.96, r = 0.92; P < 0.001). Mean estimated radiation dose revealed 0.83 ± 0.02 mSv from the unenhanced CT and 1.70 ± 0.53 mSv from the contrast enhanced CCTA. Single-source dual-energy scanning with GSI allows CAC quantification from low dose contrast enhanced CCTA by virtual iodine contrast subtraction.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24993390     DOI: 10.1007/s10554-014-0474-0

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

Review 1.  Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology.

Authors:  Stephen Schroeder; Stephan Achenbach; Frank Bengel; Christof Burgstahler; Filippo Cademartiri; Pim de Feyter; Richard George; Philipp Kaufmann; Andreas F Kopp; Juhani Knuuti; Dieter Ropers; Joanne Schuijf; Laurens F Tops; Jeroen J Bax
Journal:  Eur Heart J       Date:  2007-12-15       Impact factor: 29.983

2.  Incremental prognostic value of multi-slice computed tomography coronary angiography over coronary artery calcium scoring in patients with suspected coronary artery disease.

Authors:  Jacob M van Werkhoven; Joanne D Schuijf; Oliver Gaemperli; J Wouter Jukema; Lucia J Kroft; Eric Boersma; Aju Pazhenkottil; Ines Valenta; Gabija Pundziute; Albert de Roos; Ernst E van der Wall; Philipp A Kaufmann; Jeroen J Bax
Journal:  Eur Heart J       Date:  2009-06-29       Impact factor: 29.983

3.  Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition.

Authors:  Jelena R Ghadri; Silke M Küest; Robert Goetti; Michael Fiechter; Aju P Pazhenkottil; Rene N Nkoulou; Felix P Kuhn; Carsten Pietsch; Patrick von Schulthess; Oliver Gaemperli; Christian Templin; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2011-07-10       Impact factor: 2.357

4.  Diagnostic accuracy of 320-slice computed-tomography for detection of significant coronary artery stenosis in patients with various heart rates and heart rhythms compared with conventional coronary-angiography.

Authors:  Masae Uehara; Hiroyuki Takaoka; Yoshio Kobayashi; Nobusada Funabashi
Journal:  Int J Cardiol       Date:  2012-03-18       Impact factor: 4.164

5.  Coronary calcium score correlates with estimate of total plaque burden.

Authors:  Gani Bajraktari; Rachel Nicoll; Pranvera Ibrahimi; Fisnik Jashari; Axel Schmermund; Michael Y Henein
Journal:  Int J Cardiol       Date:  2012-11-22       Impact factor: 4.164

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Age and gender distributions of coronary artery calcium detected by electron beam tomography in 35,246 adults.

Authors:  J A Hoff; E V Chomka; A J Krainik; M Daviglus; S Rich; G T Kondos
Journal:  Am J Cardiol       Date:  2001-06-15       Impact factor: 2.778

8.  Uranium and other natural radionuclides in the sediments of a Mediterranean fjord-like embayment, Amvrakikos Gulf (Ionian Sea), Greece.

Authors:  H Papaefthymiou; D Athanasopoulos; G Papatheodorou; M Iatrou; M Geraga; D Christodoulou; S Kordella; E Fakiris; B Tsikouras
Journal:  J Environ Radioact       Date:  2013-03-27       Impact factor: 2.674

9.  Long-term prognosis associated with coronary calcification: observations from a registry of 25,253 patients.

Authors:  Matthew J Budoff; Leslee J Shaw; Sandy T Liu; Steven R Weinstein; Tristen P Mosler; Philip H Tseng; Ferdinand R Flores; Tracy Q Callister; Paolo Raggi; Daniel S Berman
Journal:  J Am Coll Cardiol       Date:  2007-04-20       Impact factor: 24.094

10.  Fully automated derivation of coronary artery calcium scores and cardiovascular risk assessment from contrast medium-enhanced coronary CT angiography studies.

Authors:  Ullrich Ebersberger; Dov Eilot; Roman Goldenberg; Alon Lev; J Reid Spears; Garrett W Rowe; Nicholas Y Gallagher; William T Halligan; Philipp Blanke; Marcus R Makowski; Aleksander W Krazinski; Justin R Silverman; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2012-09-16       Impact factor: 5.315

View more
  9 in total

Review 1.  Cardiovascular imaging 2014 in the International Journal of Cardiovascular Imaging.

Authors: 
Journal:  Int J Cardiovasc Imaging       Date:  2015-03       Impact factor: 2.357

Review 2.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

Review 3.  Cardiac CT Imaging of Plaque Vulnerability: Hype or Hope?

Authors:  Martin J Willemink; Tim Leiner; Pál Maurovich-Horvat
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

4.  An Image-Domain Contrast Material Extraction Method for Dual-Energy Computed Tomography.

Authors:  Jack W Lambert; Yuxin Sun; Robert G Gould; Michael A Ohliger; Zhixi Li; Benjamin M Yeh
Journal:  Invest Radiol       Date:  2017-04       Impact factor: 6.016

5.  Improved Calcium Scoring at Dual-Energy Computed Tomography Angiography Using a High-Z Contrast Element and Novel Material Separation Technique.

Authors:  Jack W Lambert; Yuxin Sun; Karen G Ordovas; Robert G Gould; Sizhe Wang; Benjamin M Yeh
Journal:  J Comput Assist Tomogr       Date:  2018 May/Jun       Impact factor: 1.826

Review 6.  Origins of and lessons from quantitative functional X-ray computed tomography of the lung.

Authors:  Eric A Hoffman
Journal:  Br J Radiol       Date:  2022-03-01       Impact factor: 3.629

Review 7.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

Review 8.  Dual-energy computed tomography for detection of coronary artery disease.

Authors:  Ibrahim Danad; Bríain Ó Hartaigh; James K Min
Journal:  Expert Rev Cardiovasc Ther       Date:  2015-11-07

9.  Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data.

Authors:  Jonathan Nadjiri; Georgios Kaissis; Felix Meurer; Florian Weis; Karl-Ludwig Laugwitz; Alexandra S Straeter; Daniela Muenzel; Peter B Noël; Ernst J Rummeny; Michael Rasper
Journal:  PLoS One       Date:  2018-12-06       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.