Literature DB >> 21734560

Flow field study comparing design iterations of a 50 cc left ventricular assist device.

Jason C Nanna1, Jennifer A Wivholm, Steven Deutsch, Keefe B Manning.   

Abstract

The Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) study shows that implanted ventricular assist devices improve survival time and quality of life when used as a permanent therapy in patients who do not qualify for heart transplant. The success of the pulsatile 70 cc stroke volume left ventricular assist device (LVAD) developed by Penn State has led to the development of a 50 cc stroke volume pump for use in patients with smaller chest cavities to benefit a larger patient population. The initial 50 cc pump shows regions of in vivo thrombus formation, which correlate to low wall shear rates within the device. In an in vitro evaluation of three new designs (V-2, V-3, and V-4) of the 50 cc LVAD, identical except for the location and orientation of their outlet ports, particle image velocimetry (PIV) is used to capture planar flow field data within the pumps. V-2 has an outlet port that is located parallel to the inlet. In V-3, the outlet port is rotated away from the inlet port, with the intention of minimizing the amount of fluid turning needed to exit the device. With V-4 the outlet port is moved to the center of the pump to prolong the desirable rotational flow. PIV data were taken at six planar locations within the pump. Although the modifications to the outlet port locations serve their intended purpose, they also introduce unwanted changes in the flow. Poorer wall washing and weaker rotational flow are observed with V-3 and V-4. Although the differences between the devices are subtle, the device that has the most desirable flow characteristics is V-2.

Entities:  

Mesh:

Year:  2011        PMID: 21734560      PMCID: PMC3163059          DOI: 10.1097/MAT.0b013e318224e20b

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  20 in total

1.  Diaphragm motion affects flow patterns in an artificial heart.

Authors:  Pramote Hochareon; Keefe B Manning; Arnold A Fontaine; Steven Deutsch; John M Tarbell
Journal:  Artif Organs       Date:  2003-12       Impact factor: 3.094

2.  Wall shear-rate estimation within the 50cc Penn State artificial heart using particle image velocimetry.

Authors:  Pramote Hochareon; Keefe B Manning; Arnold A Fontaine; John M Tarbell; Steven Deutsch
Journal:  J Biomech Eng       Date:  2004-08       Impact factor: 2.097

3.  Correlation of in vivo clot deposition with the flow characteristics in the 50 cc penn state artificial heart: a preliminary study.

Authors:  Pramote Hochareon; Keefe B Manning; Arnold A Fontaine; John M Tarbell; Steven Deutsch
Journal:  ASAIO J       Date:  2004 Nov-Dec       Impact factor: 2.872

4.  Fluid dynamic analysis of the 50 cc Penn State artificial heart under physiological operating conditions using particle image velocimetry.

Authors:  Pramote Hochareon; Keefe B Manning; Arnold A Fontaine; John M Tarbell; Steven Deutsch
Journal:  J Biomech Eng       Date:  2004-10       Impact factor: 2.097

5.  Fluid dynamic optimization of a ventricular assist device using particle image velocimetry.

Authors:  T Mussivand; K D Day; B C Naber
Journal:  ASAIO J       Date:  1999 Jan-Feb       Impact factor: 2.872

6.  Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock.

Authors:  K Nakata; M Shiono; Y Orime; M Hata; A Sezai; T Saitoh; Y Sezai
Journal:  Artif Organs       Date:  1996-06       Impact factor: 3.094

7.  Renal circulation and cellular metabolism during left ventricular assisted circulation: comparison study of pulsatile and nonpulsatile assists.

Authors:  A Sezai; M Shiono; Y Orime; K Nakata; M Hata; H Yamada; M Iida; S Kashiwazaki; J Kinishita; M Nemoto; T Koujima; Y Sezai; T Saitoh
Journal:  Artif Organs       Date:  1997-07       Impact factor: 3.094

8.  Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model.

Authors:  George V Letsou; Thomas D Pate; Jeffrey R Gohean; Mark Kurusz; Raul G Longoria; Larry Kaiser; Richard W Smalling
Journal:  J Thorac Cardiovasc Surg       Date:  2010-05-23       Impact factor: 5.209

9.  Bridge to transplantation: the Penn State experience.

Authors:  D Mavroidis; B C Sun; W E Pae
Journal:  Ann Thorac Surg       Date:  1999-08       Impact factor: 4.330

10.  Visualization and analysis of mural thrombogenesis on collagen, polyurethane and nylon.

Authors:  J A Hubbell; L V McIntire
Journal:  Biomaterials       Date:  1986-09       Impact factor: 12.479

View more
  6 in total

1.  A fluid dynamics study in a 50 cc pulsatile ventricular assist device: influence of heart rate variability.

Authors:  Jason C Nanna; Michael A Navitsky; Stephen R Topper; Steven Deutsch; Keefe B Manning
Journal:  J Biomech Eng       Date:  2011-10       Impact factor: 2.097

2.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

3.  The Use of Fluid Mechanics to Predict Regions of Microscopic Thrombus Formation in Pulsatile VADs.

Authors:  Stephen R Topper; Michael A Navitsky; Richard B Medvitz; Eric G Paterson; Christopher A Siedlecki; Margaret J Slattery; Steven Deutsch; Gerson Rosenberg; Keefe B Manning
Journal:  Cardiovasc Eng Technol       Date:  2014-03-01       Impact factor: 2.495

4.  A thrombus susceptibility comparison of two pulsatile Penn State 50 cc left ventricular assist device designs.

Authors:  Michael A Navitsky; Steven Deutsch; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2012-07-24       Impact factor: 3.934

5.  Platelet adhesion to polyurethane urea under pulsatile flow conditions.

Authors:  Michael A Navitsky; Joshua O Taylor; Alexander B Smith; Margaret J Slattery; Steven Deutsch; Christopher A Siedlecki; Keefe B Manning
Journal:  Artif Organs       Date:  2014-04-09       Impact factor: 3.094

6.  Numerical investigation of the effect of cannula placement on thrombosis.

Authors:  ChiWei Ong; Socrates Dokos; BeeTing Chan; Einly Lim; Amr Al Abed; Noor Azuan Bin Abu Osman; Suhaini Kadiman; Nigel H Lovell
Journal:  Theor Biol Med Model       Date:  2013-05-16       Impact factor: 2.432

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.