Literature DB >> 15648811

Fluid dynamic analysis of the 50 cc Penn State artificial heart under physiological operating conditions using particle image velocimetry.

Pramote Hochareon1, Keefe B Manning, Arnold A Fontaine, John M Tarbell, Steven Deutsch.   

Abstract

In order to bridge the gap of existing artificial heart technology to the diverse needs of the patient population, we have been investigating the viability of a scaled-down design of the current 70 cc Penn State artificial heart. The issues of clot formation and hemolysis may become magnified within a 50 cc chamber compared to the existing 70 cc one. Particle image velocimetry (PIV) was employed to map the entire 50 cc Penn State artificial heart chamber. Flow fields constructed from PIV data indicate a rotational flow pattern that provides washout during diastole. In addition, shear rate maps were constructed for the inner walls of the heart chamber The lateral walls of the mitral and aortic ports experience high shear rates while the upper and bottom walls undergo low shear rates, with sufficiently long exposure times to potentially induce platelet activation or thrombus formation. In this study, we have demonstrated that PIV may adequately map the flow fields accurately in a reasonable amount of time. Therefore, the potential exists of employing PIV as a design tool.

Entities:  

Mesh:

Year:  2004        PMID: 15648811     DOI: 10.1115/1.1798056

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  9 in total

1.  A fluid dynamics study in a 50 cc pulsatile ventricular assist device: influence of heart rate variability.

Authors:  Jason C Nanna; Michael A Navitsky; Stephen R Topper; Steven Deutsch; Keefe B Manning
Journal:  J Biomech Eng       Date:  2011-10       Impact factor: 2.097

2.  Near valve flows and potential blood damage during closure of a bileaflet mechanical heart valve.

Authors:  L H Herbertson; S Deutsch; K B Manning
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

3.  Validation of a CFD methodology for positive displacement LVAD analysis using PIV data.

Authors:  Richard B Medvitz; Varun Reddy; Steve Deutsch; Keefe B Manning; Eric G Paterson
Journal:  J Biomech Eng       Date:  2009-11       Impact factor: 2.097

4.  Flow field study comparing design iterations of a 50 cc left ventricular assist device.

Authors:  Jason C Nanna; Jennifer A Wivholm; Steven Deutsch; Keefe B Manning
Journal:  ASAIO J       Date:  2011 Sep-Oct       Impact factor: 2.872

5.  The Use of Fluid Mechanics to Predict Regions of Microscopic Thrombus Formation in Pulsatile VADs.

Authors:  Stephen R Topper; Michael A Navitsky; Richard B Medvitz; Eric G Paterson; Christopher A Siedlecki; Margaret J Slattery; Steven Deutsch; Gerson Rosenberg; Keefe B Manning
Journal:  Cardiovasc Eng Technol       Date:  2014-03-01       Impact factor: 2.495

6.  A thrombus susceptibility comparison of two pulsatile Penn State 50 cc left ventricular assist device designs.

Authors:  Michael A Navitsky; Steven Deutsch; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2012-07-24       Impact factor: 3.934

Review 7.  Hypoplastic left heart syndrome: current considerations and expectations.

Authors:  Jeffrey A Feinstein; D Woodrow Benson; Anne M Dubin; Meryl S Cohen; Dawn M Maxey; William T Mahle; Elfriede Pahl; Juan Villafañe; Ami B Bhatt; Lynn F Peng; Beth Ann Johnson; Alison L Marsden; Curt J Daniels; Nancy A Rudd; Christopher A Caldarone; Kathleen A Mussatto; David L Morales; D Dunbar Ivy; J William Gaynor; James S Tweddell; Barbara J Deal; Anke K Furck; Geoffrey L Rosenthal; Richard G Ohye; Nancy S Ghanayem; John P Cheatham; Wayne Tworetzky; Gerard R Martin
Journal:  J Am Coll Cardiol       Date:  2012-01-03       Impact factor: 24.094

Review 8.  Towards non-thrombogenic performance of blood recirculating devices.

Authors:  D Bluestein; K B Chandran; K B Manning
Journal:  Ann Biomed Eng       Date:  2010-02-04       Impact factor: 3.934

9.  Finite element analysis of stresses developed in the blood sac of a left ventricular assist device.

Authors:  T L Haut Donahue; W Dehlin; J Gillespie; W J Weiss; G Rosenberg
Journal:  Med Eng Phys       Date:  2009-01-07       Impact factor: 2.242

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.