Literature DB >> 10475471

Bridge to transplantation: the Penn State experience.

D Mavroidis1, B C Sun, W E Pae.   

Abstract

BACKGROUND: During the past decade, ventricular assist devices as a bridge to transplantation have moved from the experimental arena to accepted therapy. Our institution has been at the forefront of the development of this technology and consequently has had extensive experience with the devices that are currently approved by the Food and Drug Administration for use as a bridge to heart transplantation.
METHODS: The successful management of patients with assist devices hinges on patient and device selection as well as perioperative management strategies. The routine use of agents such as aprotinin, vasopressin, milrinone, and inhaled nitric oxide has contributed to successful management of these patients. We present our perspectives on the advantages and disadvantages of the Thermo-Cardiosystems HeartMate 1000 IP device and the Thoratec (Pierce-Donachy) system. We also discuss our protocols and methods for patient selection, preoperative preparation, intraoperative strategy, and postoperative management that have resulted in improved patient outcomes.
RESULTS: More than 60 device implantation procedures have been performed since the inception of our bridge to transplantation program. During this time, two thirds of our patients were successfully bridged to transplantation. Of these patients, 92% were alive at 1 month after transplantation, and 83% were alive at 1 year after transplantation.
CONCLUSIONS: Both support systems are effective in supporting patients to heart transplantation. We have developed a preference for the Thermo-Cardiosystems HeartMate 1000 IP device because of its portability and associated better quality of life. However, the Thoratec device is the more versatile device, and circumstances exist when its use is clearly advantageous. In our institutional experience, outcome for bridging to transplantation has not been device dependent.

Entities:  

Mesh:

Year:  1999        PMID: 10475471     DOI: 10.1016/s0003-4975(98)01314-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

Review 1.  Novel Left Ventricular Assist System: an electrocardiogram-synchronized LVAS that avoids cardiac cannulation.

Authors:  Domingo Liotta
Journal:  Tex Heart Inst J       Date:  2003

2.  Inhaled nitric oxide therapy in adults: European expert recommendations.

Authors:  Peter Germann; Antonio Braschi; Giorgio Della Rocca; Anh Tuan Dinh-Xuan; Konrad Falke; Claes Frostell; Lars E Gustafsson; Philippe Hervé; Philippe Jolliet; Udo Kaisers; Hector Litvan; Duncan J Macrae; Marco Maggiorini; Nandor Marczin; Bernd Mueller; Didier Payen; Marco Ranucci; Dietmar Schranz; Rainer Zimmermann; Roman Ullrich
Journal:  Intensive Care Med       Date:  2005-06-23       Impact factor: 17.440

3.  Flow field study comparing design iterations of a 50 cc left ventricular assist device.

Authors:  Jason C Nanna; Jennifer A Wivholm; Steven Deutsch; Keefe B Manning
Journal:  ASAIO J       Date:  2011 Sep-Oct       Impact factor: 2.872

Review 4.  Myocardial infarction (ST-elevation).

Authors:  Abel P Wakai
Journal:  BMJ Clin Evid       Date:  2011-01-07

Review 5.  Myocardial infarction (ST-elevation).

Authors:  Abel P Wakai
Journal:  BMJ Clin Evid       Date:  2009-01-09

Review 6.  Perioperative pharmacotherapy in patients with left ventricular assist devices.

Authors:  Nicholas C Dang; Yoshifumi Naka
Journal:  Drugs Aging       Date:  2004       Impact factor: 4.271

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.