Literature DB >> 21731145

Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome.

Ming Teo1, Terence Amis, Sharon Lee, Karina Falland, Stephen Lambert, John Wheatley.   

Abstract

STUDY
OBJECTIVE: Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces.
DESIGN: Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights.
SETTING: Accredited laboratory in a university hospital. PATIENTS OR PARTICIPANTS: Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour.
INTERVENTIONS: CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. MEASUREMENTS AND
RESULTS: There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H(2)O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask.
CONCLUSIONS: Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. CLINICAL TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx

Entities:  

Keywords:  Obstructive sleep apnea; continuous positive airway pressure; mask leak; nasal; oronasal

Mesh:

Year:  2011        PMID: 21731145      PMCID: PMC3119837          DOI: 10.5665/SLEEP.1134

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  17 in total

Review 1.  Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force.

Authors: 
Journal:  Sleep       Date:  1999-08-01       Impact factor: 5.849

2.  Proposed supplements and amendments to 'A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects', the Rechtschaffen & Kales (1968) standard.

Authors:  T Hori; Y Sugita; E Koga; S Shirakawa; K Inoue; S Uchida; H Kuwahara; M Kousaka; T Kobayashi; Y Tsuji; M Terashima; K Fukuda; N Fukuda
Journal:  Psychiatry Clin Neurosci       Date:  2001-06       Impact factor: 5.188

3.  Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome.

Authors:  J C Meurice; J Paquereau; A Denjean; F Patte; F Series
Journal:  Eur Respir J       Date:  1998-05       Impact factor: 16.671

Review 4.  Practice parameters for the indications for polysomnography and related procedures: an update for 2005.

Authors:  Clete A Kushida; Michael R Littner; Timothy Morgenthaler; Cathy A Alessi; Dennis Bailey; Jack Coleman; Leah Friedman; Max Hirshkowitz; Sheldon Kapen; Milton Kramer; Teofilo Lee-Chiong; Daniel L Loube; Judith Owens; Jeffrey P Pancer; Merrill Wise
Journal:  Sleep       Date:  2005-04       Impact factor: 5.849

5.  Efficacy of a new full face mask for noninvasive positive pressure ventilation.

Authors:  G J Criner; J M Travaline; K J Brennan; D T Kreimer
Journal:  Chest       Date:  1994-10       Impact factor: 9.410

6.  Effects of mouth opening on upper airway collapsibility in normal sleeping subjects.

Authors:  J C Meurice; I Marc; G Carrier; F Sériès
Journal:  Am J Respir Crit Care Med       Date:  1996-01       Impact factor: 21.405

7.  Comparison of nose and face mask CPAP therapy for sleep apnoea.

Authors:  I L Mortimore; A T Whittle; N J Douglas
Journal:  Thorax       Date:  1998-04       Impact factor: 9.139

8.  Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders.

Authors:  Clete A Kushida; Michael R Littner; Max Hirshkowitz; Timothy I Morgenthaler; Cathy A Alessi; Dennis Bailey; Brian Boehlecke; Terry M Brown; Jack Coleman; Leah Friedman; Sheldon Kapen; Vishesh K Kapur; Milton Kramer; Teofilo Lee-Chiong; Judith Owens; Jeffrey P Pancer; Todd J Swick; Merrill S Wise
Journal:  Sleep       Date:  2006-03       Impact factor: 5.849

Review 9.  Continuous positive airway pressure delivery interfaces for obstructive sleep apnoea.

Authors:  C L Chai; A Pathinathan; B Smith
Journal:  Cochrane Database Syst Rev       Date:  2006-10-18

10.  Reliability of home CPAP titration with different automatic CPAP devices.

Authors:  Frédéric Sériès; Julie Plante; Yves Lacasse
Journal:  Respir Res       Date:  2008-07-24
View more
  26 in total

1.  Obstructive sleep apnoea and non-restorative sleep induced by the interface.

Authors:  Michael Westhoff; Patric Litterst
Journal:  Sleep Breath       Date:  2015-04-16       Impact factor: 2.816

2.  Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment.

Authors:  Susheel P Patil; Indu A Ayappa; Sean M Caples; R Joh Kimoff; Sanjay R Patel; Christopher G Harrod
Journal:  J Clin Sleep Med       Date:  2019-02-15       Impact factor: 4.062

3.  A new predictive model for continuous positive airway pressure in the treatment of obstructive sleep apnea.

Authors:  Matthew R Ebben; Mariya Narizhnaya; Ana C Krieger
Journal:  Sleep Breath       Date:  2016-11-22       Impact factor: 2.816

4.  A Randomized Crossover Trial Comparing Autotitrating and Continuous Positive Airway Pressure in Subjects With Symptoms of Aerophagia: Effects on Compliance and Subjective Symptoms.

Authors:  Teresa Shirlaw; Kevin Hanssen; Brett Duce; Craig Hukins
Journal:  J Clin Sleep Med       Date:  2017-07-15       Impact factor: 4.062

5.  Nasal versus oronasal continuous positive airway pressure masks for obstructive sleep apnea: is this really a key point of effectiveness?

Authors:  Antonio M Esquinas; Zeynep Zeren Ucar; Cenk Kirakli
Journal:  Sleep Breath       Date:  2013-04-08       Impact factor: 2.816

6.  Higher effective oronasal versus nasal continuous positive airway pressure in obstructive sleep apnea: effect of mandibular stabilization.

Authors:  Marta Kaminska; Andree Montpetit; Annie Mathieu; Vincent Jobin; Florence Morisson; Pierre Mayer
Journal:  Can Respir J       Date:  2014-05-02       Impact factor: 2.409

7.  Effect of addition of chin strap on PAP compliance, nightly duration of use, and other factors.

Authors:  Shelley R Knowles; Daniel T O'Brien; Shiling Zhang; Anupama Devara; James A Rowley
Journal:  J Clin Sleep Med       Date:  2014-04-15       Impact factor: 4.062

8.  CPAP Use: Unmasking the Truth about Interface.

Authors:  Rohit Budhiraja; Jessie P Bakker
Journal:  J Clin Sleep Med       Date:  2016-09-15       Impact factor: 4.062

9.  Comparison of the upper airway dynamics of oronasal and nasal masks with positive airway pressure treatment using cine magnetic resonance imaging.

Authors:  Matthew R Ebben; Sara Milrad; Jonathan P Dyke; C Douglas Phillips; Ana C Krieger
Journal:  Sleep Breath       Date:  2015-04-30       Impact factor: 2.816

10.  Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea.

Authors:  Sheetal Deshpande; Simon Joosten; Anthony Turton; Bradley A Edwards; Shane Landry; Darren R Mansfield; Garun S Hamilton
Journal:  J Clin Sleep Med       Date:  2016-09-15       Impact factor: 4.062

View more