Literature DB >> 24791252

Higher effective oronasal versus nasal continuous positive airway pressure in obstructive sleep apnea: effect of mandibular stabilization.

Marta Kaminska, Andree Montpetit, Annie Mathieu, Vincent Jobin, Florence Morisson, Pierre Mayer.   

Abstract

BACKGROUND: In some individuals with obstructive sleep apnea (OSA), oronasal continuous positive airway pressure (CPAP) leads to poorer OSA correction than nasal CPAP. The authors hypothesized that this results from posterior mandibular displacement caused by the oronasal mask.
OBJECTIVE: To test this hypothesis using a mandibular advancement device (MAD) for mandibular stabilization.
METHODS: Subjects whose OSA was not adequately corrected by oronasal CPAP at pressures for which nasal CPAP was effective were identified. These subjects underwent polysomnography (PSG) CPAP titration with each nasal and oronasal mask consecutively, with esophageal pressure and leak monitoring, to obtain the effective pressure (Peff) of CPAP for correcting obstructive events with each mask (maximum 20 cmH2O). PSG titration was repeated using a MAD in the neutral position. Cephalometry was performed.
RESULTS: Six subjects with mean (± SD) nasal Peff 10.4±3.0 cmH2O were studied. Oronasal Peff was greater than nasal Peff in all subjects, with obstructive events persisting at 20 cmH2O by oronasal mask in four cases. This was not due to excessive leak. With the MAD, oronasal Peff was reduced in three subjects, and Peff <20 cmH2O could be obtained in two of the four subjects with Peff >20 cmH2O by oronasal mask alone. Subjects' cephalometric variables were similar to published norms.
CONCLUSION: In subjects with OSA with higher oronasal than nasal Peff, this is partially explained by posterior mandibular displacement caused by the oronasal mask. Combination treatment with oronasal mask and MAD may be useful in some individuals if a nasal mask is not tolerated.

Entities:  

Mesh:

Year:  2014        PMID: 24791252      PMCID: PMC4173891          DOI: 10.1155/2014/408073

Source DB:  PubMed          Journal:  Can Respir J        ISSN: 1198-2241            Impact factor:   2.409


  26 in total

1.  Proposed supplements and amendments to 'A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects', the Rechtschaffen & Kales (1968) standard.

Authors:  T Hori; Y Sugita; E Koga; S Shirakawa; K Inoue; S Uchida; H Kuwahara; M Kousaka; T Kobayashi; Y Tsuji; M Terashima; K Fukuda; N Fukuda
Journal:  Psychiatry Clin Neurosci       Date:  2001-06       Impact factor: 5.188

2.  Cephalometric and physiologic predictors of the efficacy of an adjustable oral appliance for treating obstructive sleep apnea.

Authors:  Y Liu; A A Lowe; J A Fleetham; Y C Park
Journal:  Am J Orthod Dentofacial Orthop       Date:  2001-12       Impact factor: 2.650

3.  A cephalometric and electromyographic study of upper airway structures in the upright and supine positions.

Authors:  E K Pae; A A Lowe; K Sasaki; C Price; M Tsuchiya; J A Fleetham
Journal:  Am J Orthod Dentofacial Orthop       Date:  1994-07       Impact factor: 2.650

4.  A method of cephalometric evaluation.

Authors:  J A McNamara
Journal:  Am J Orthod       Date:  1984-12

5.  Upper airway pressure-flow relationships in obstructive sleep apnea.

Authors:  P L Smith; R A Wise; A R Gold; A R Schwartz; S Permutt
Journal:  J Appl Physiol (1985)       Date:  1988-02

6.  The occurrence of sleep-disordered breathing among middle-aged adults.

Authors:  T Young; M Palta; J Dempsey; J Skatrud; S Weber; S Badr
Journal:  N Engl J Med       Date:  1993-04-29       Impact factor: 91.245

7.  CPAP therapy via oronasal mask for obstructive sleep apnea.

Authors:  M H Sanders; N B Kern; R A Stiller; P J Strollo; T J Martin; C W Atwood
Journal:  Chest       Date:  1994-09       Impact factor: 9.410

8.  The effects of a nonsurgical treatment for obstructive sleep apnea. The tongue-retaining device.

Authors:  R D Cartwright; C F Samelson
Journal:  JAMA       Date:  1982-08-13       Impact factor: 56.272

9.  Oral-nasal continuous positive airway pressure as a treatment for obstructive sleep apnea.

Authors:  G L Prosise; R B Berry
Journal:  Chest       Date:  1994-07       Impact factor: 9.410

10.  Effects of mouth opening on upper airway collapsibility in normal sleeping subjects.

Authors:  J C Meurice; I Marc; G Carrier; F Sériès
Journal:  Am J Respir Crit Care Med       Date:  1996-01       Impact factor: 21.405

View more
  11 in total

Review 1.  New developments in the use of positive airway pressure for obstructive sleep apnea.

Authors:  Lucas M Donovan; Schafer Boeder; Atul Malhotra; Sanjay R Patel
Journal:  J Thorac Dis       Date:  2015-08       Impact factor: 2.895

2.  Pressure Requirements With a Nasal Versus Oronasal Mask During a PAP Titration Study.

Authors:  Hao Cheng; Anita Valanju Shelgikar
Journal:  J Clin Sleep Med       Date:  2019-04-15       Impact factor: 4.062

3.  Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment.

Authors:  Susheel P Patil; Indu A Ayappa; Sean M Caples; R Joh Kimoff; Sanjay R Patel; Christopher G Harrod
Journal:  J Clin Sleep Med       Date:  2019-02-15       Impact factor: 4.062

4.  Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series.

Authors:  Justin R Ng; Vinod Aiyappan; Jeremy Mercer; Peter G Catcheside; Ching Li Chai-Coetzer; R Doug McEvoy; Nick Antic
Journal:  J Clin Sleep Med       Date:  2016-09-15       Impact factor: 4.062

5.  Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea.

Authors:  Sheetal Deshpande; Simon Joosten; Anthony Turton; Bradley A Edwards; Shane Landry; Darren R Mansfield; Garun S Hamilton
Journal:  J Clin Sleep Med       Date:  2016-09-15       Impact factor: 4.062

6.  Body Position May Influence Oronasal CPAP Effectiveness to Treat OSA.

Authors:  Juliana Araújo Nascimento; Tômas de Santana Carvalho; Henrique Takachi Moriya; Paulo Henrique Sousa Fernandes; Rafaela Garcia Santos de Andrade; Pedro Rodrigues Genta; Geraldo Lorenzi-Filho; Naomi Kondo Nakagawa
Journal:  J Clin Sleep Med       Date:  2016-03       Impact factor: 4.062

Review 7.  Treatment of Obstructive Sleep Apnea. Prospects for Personalized Combined Modality Therapy.

Authors:  Naomi L Deacon; Rachel Jen; Yanru Li; Atul Malhotra
Journal:  Ann Am Thorac Soc       Date:  2016-01

8.  Use of the WatchPAT to detect occult residual sleep-disordered breathing in patients on CPAP for obstructive sleep apnea.

Authors:  Matthew Epstein; Tariq Musa; Stephanie Chiu; Jacquelyn Costanzo; Christine Dunne; Federico Cerrone; Robert Capone
Journal:  J Clin Sleep Med       Date:  2020-07-15       Impact factor: 4.062

Review 9.  Update on Oral Appliance Therapy for OSA.

Authors:  M Marklund
Journal:  Curr Sleep Med Rep       Date:  2017-07-10

10.  Obstructive sleep apnea: in search of precision.

Authors:  Manuel Sânchez-de-la-Torre; David Gozal
Journal:  Expert Rev Precis Med Drug Dev       Date:  2017-08-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.