Literature DB >> 21725621

Optimization of the radiological protection of patients undergoing digital radiography.

Menglong Zhang1, Cunkun Chu.   

Abstract

Because of a much higher dynamic range of flat panel detectors, patient dose can vary without change of image quality being perceived by radiologists. This condition makes optimization (OT) of radiation protection undergoing digital radiography (DR) more complex, while a chance to reduced patient dose also exists. In this study, we evaluated the difference of patient radiation and image rejection before and after OT to identify if it is necessary to carry out an OT procedure in a routine task with DR. The study consisted of a measurement of the dose area product (DAP) and entrance surface dose (ESD) received by a reference group of patients for eight common radiographic procedures using the DR system before and after OT. Meanwhile image rejection data during two 2-month periods were collected and sorted according to reason. For every radiographic procedure, t tests showed significant difference in average ESD and DAP before and after OT (p < 0.005). The ESDs from most examinations before OT were three times higher than that after OT. For DAPs, the difference is more significant. Image rejection rate after OT is significantly lower than that before OT (χ (2) = 36.5, p < 0.005). The substantial reductions of dose after OT resulted from appropriate mAs and exposure field. For DR patient dose, less than recommended diagnostic reference level can meet quality criteria and clinic diagnosis.

Entities:  

Mesh:

Year:  2012        PMID: 21725621      PMCID: PMC3264715          DOI: 10.1007/s10278-011-9395-9

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  7 in total

1.  [Management of dose and quality in digital radiography].

Authors:  H P Busch
Journal:  Rofo       Date:  2003-01

2.  Managing patient dose in digital radiology. A report of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  2004

3.  Reference values for diagnostic radiology: application and impact.

Authors:  Joel E Gray; Benjamin R Archer; Priscilla F Butler; Barry B Hobbs; Fred A Mettler; Robert J Pizzutiello; Beth A Schueler; Keith J Strauss; Orhan H Suleiman; Martin J Yaffe
Journal:  Radiology       Date:  2005-03-09       Impact factor: 11.105

Review 4.  Dose and perceived image quality in chest radiography.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Jacob Geleijns
Journal:  Eur J Radiol       Date:  2009-07-03       Impact factor: 3.528

5.  One year's results from a server-based system for performing reject analysis and exposure analysis in computed radiography.

Authors:  A Kyle Jones; Raimund Polman; Charles E Willis; S Jeff Shepard
Journal:  J Digit Imaging       Date:  2011-04       Impact factor: 4.056

6.  Optimization of dose and image quality for computed radiography and digital radiography.

Authors:  John E Aldrich; Emerenciana Duran; Pat Dunlop; John R Mayo
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

Review 7.  Digital chest radiography: an update on modern technology, dose containment and control of image quality.

Authors:  Cornelia Schaefer-Prokop; Ulrich Neitzel; Henk W Venema; Martin Uffmann; Mathias Prokop
Journal:  Eur Radiol       Date:  2008-04-23       Impact factor: 5.315

  7 in total
  3 in total

1.  A method to derive appropriate exposure parameters from target exposure index and patient thickness in pediatric digital radiography.

Authors:  Menglong Zhang; Kai Liu; Xuecai Niu; Xinli Liu
Journal:  Pediatr Radiol       Date:  2012-12-04

2.  Educational Module Intervention for Radiographers to Reduce Repetition Rate of Routine Digital Chest Radiography in Makkah Region of Saudi Arabia Tertiary Hospitals: Protocol of a Quasi-Experimental Study.

Authors:  Rosliza Abdul Manaf; Abdullah A Almalki; Muhamad Hanafiah Juni; Hayati Kadir Shahar; Noramaliza Mohd Noor; Abdelsafi Gabbad
Journal:  JMIR Res Protoc       Date:  2017-09-26

3.  Reject rate analysis in digital radiography: an Australian emergency imaging department case study.

Authors:  Samantha Atkinson; Michael Neep; Deborah Starkey
Journal:  J Med Radiat Sci       Date:  2019-07-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.